EG-3SLM (STAND-ALONE MASTER)
6.0 installation of EG-3 to function in mode EG-3SLM
In the mode EG-3SLM, the EG-3 will function in the same way as a
wireless “PEGASO” control panel.
To activate the EG-3SLM in this mode, set the dip switch as shown in fig. 4 to
the right. Once set the EG-3SLM must be initialized.
Make sure that the “on/off” switch located in the battery compartment is in
“OFF” position. Connect the power supply cable based on the polarity to the
terminals 1 and 2 as indicated in Section 3.1. Plug in the back-up battery
cable and switch to “ON” position the “on/off” switch. Press continuously the
RESET/LEARN button located in the battery compartment and after about 8
seconds the EG-3SLM will emit 3 beeps. Release the reset button and after
another 45 seconds an additional 2 beeps will be heard. This confirms that the
EG-SLM has been successfully initialized.
Note: During this initialization period the RED LED 1 will light and immediately
after. If GPRS signal is present this same LED become green.
The EG-3SLM, in this mode, can memorize 20 slave sensors that have the “Pegaso” codes. This
means that the EG-3SLM has now become a full 20 zone wireless control panel with SMS and
MMS data transmission. It may memorize all the “Pegaso” sensor available which are:
PIR sensors, Double technology sensors, Optical smoke detectors, Magnetic contacts, Vibrations
sensors, Gas detections sensor and others. See section 6.1 for the instruction of how to memorize
all sensors. Arming and disarming of the EG-3SLM is done through a PEG-3 keychain transmitter.
Note: EG-3SLM once armed, has an exit time of about 25 sec. before entering into full function.
The EG-3SLM, when triggered will send a R.F. trigger command to an outdoor wireless “Pegaso”
series siren and a memorized SMS message to 4 memorized telephone numbers. The EG-SLM on
board PIR SENSOR will then become active and if triggered will send to the same 4 telephone
numbers and to 2 E-mail addresses 5 MMS images of the protected area. In addition with the PEG-3
keychain transmitter a PANIC alarm may be triggered by pressing one of the 3 buttons (see section
2.3). Also with SM-2 smoke detectors installed a FIRE alarm maybe trigger.
The burglary alarm is active only with the EG-3SLM is in armed mode. The panic, fire and tamper
alarm functions are active with unit armed or disarmed. Each alarm trigger will be handled in the
same way. First the SMS message will be sent indicating the type of alarm. Then the EG-3SLM on
board PIR sensor will become activate and if its protected area is violated, 5 MMS images will be
sent to the Memorized Telephone numbers and E-mail addresses.
To program the tel. numbers, SMS messages and E-mail addresses, see section 7.0.
For each alarm trigger, the EG-3SLM will memorize an additional 32 images on the on-board micro
SD card. These images may be seen using an SD card reader.
With remote SMS commands, you may request from the EG-3SLM in armed status:
1. To change, for 5 seconds, the state of the on-board relay contact, outputs (COM, NO, NC).
May be used to arm/disarm the control panel or for home automation (see section 3.1).
2. To enter into listen-in or two way communication function and hear what is taking place in the
protected area (see section 8.1).
3. To request that images be sent as periodic control of the protected area (see section 7.0).
4. To change the memorized telephone numbers and E-mail addresses (see section 7.0).
If the EG-3SLM is triggered by one of the installed slave sensors, and the EG-3SLM on-board
PIR sensor does not detect any movement, no MMS or E-mail images will be sent.
1 2 3 4
Fig. 6
MODALITA’ SLM
+
-
Page 30
EG-3 Instruction manual
ENGLISH