background image

ACOUSTIC  MASTER

2

Channel 2 EFX Loop

CH2 EFX-Send 

This jack is located on the back panel. The signal is sent 

dry, with no equalization.

CH2 EFX-Return

This jack is located at the back of the unit. When a signal 

is fed back into the CH2 EFX-RTN jack it can go directly 

into the amps or it can be combined with the internal 

digital effects depending on whether the Channel 2 EFX 

switch is in or out.

Do not use both the phone and XLR inputs at the same time, 

signals will be highly attenuated!! 

Effects Level Control (dry/wet)

This control is used to increase or decrease the amount 

of internal effects used to enhance the sound from an 

input source on either Channel 1 or 2. The effects level 

control can be bypassed via a foot switch. 

Master Volume

The master control is used to increase or decrease the 

overall output of the AM100. It has no effect on the line 

out signal level or the Channel 2 effects loop. 

Line Out

The Line Out is post Channel 1 and 2 but pre-effects, the 

gain controls and Channel 1’s equalization do affect the 

output to the balanced line out, but the master volume 

control does not. No effects are sent through this output 

unless used prior to the amplifier (e.g. If you have your 

guitar plugged directly into an effect, then plugged into 

the AM100). You can use this output to directly connect 

to a mixer, or another amplifier.

Digital Effects 

There are 32-digital effects presets altogether in Banks A 

and B, with 16-presets for each. Bank A and Bank B are 

switchable via a bank select switch on the front panel of 

the amp. When the switch is in the In position, an amber 

LED is turned on indicating Bank A is enabled. In the Out 

position, Bank B is enabled and the light goes out. This 

feature can also be accessed using an optional footswitch.

Digital Effects Bank A/B 

The AM100 has 2 banks consisting of 16-presets for 

each. The numeric selection of each preset and its 

description is located on the front panel. An Effects 

Table with brief descriptions for the presets is located 

near the end of the Owner’s Manual.

Footswitch 

Connect a standard footswitch here to turn the internal 

effects system on or off. It does not regulate the external 

effects loop.

Specifications

Power @ min. impedance (Watts)

100

Minimum Impedance (ohms)

8

Burst Power - 2 cycle

140 Watts

Speaker Configuration - LF (Size / Power)

2x 6.5 inch / 50 Watts each

Speaker Configuration - HF (Size / Power)

3.75 inch / 30 Watts

Input Channels

2

Channel 1 - inputs

1/4 inch TRS

Channel 1 - controls

Gain, Low, Mid, High, Frequency Notch Filter

Channel 1 - switches

Frequency Notch Filter Defeat

Channel 2 - inputs

1/4 inch TRS, XLR

Channel 2 - controls

Gain

Channel 2 - switches

Internal Effects Defeat

Master Volume Control

Yes

Input Sensitivity (mV)

ch 1=100, ch 2=1V

Line Out (type / configuration)

XLR / Rear

Line Out Sensitivity (Vrms)

1

Effects Volume

Yes

Effects Loop / Location

Yes (ch 2 only) / Rear

Effects Footswitch / Function

Optional / Internal Effects Bypass

Internal Reverb / Effects

Digital Effects, 16 x 2 banks

LED Indicators

Power, Clip, EFX Bank

Dimensions (DWH, inches)

12 x 19 x 14

Dimensions (DWH, cm)

30 x 48 x 36

Weight (lbs / kg)

27.5 / 12.5

Summary of Contents for Acoustic Master AM100

Page 1: ...O W N E R S M A N U A L G U I D E D E L U T I L I S A T E U R Traynor Acoustic Master A M 1 0 0 ACOUSTIC MASTER MODEL TYPE YS1004...

Page 2: ...UE DE CHOC ELECTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT INSTRUCTIONS RELATIVES AU R...

Page 3: ...oard or even another acoustic guitar using an active pick up can be in use on Channel 2 Power The green LED located under the power switch will illuminate when the unit is turned on Channel 1 The inpu...

Page 4: ...for each Bank A and Bank B are switchable via a bank select switch on the front panel of the amp When the switch is in the In position an amber LED is turned on indicating Bank A is enabled In the Out...

Page 5: ...tr le LOW sera utilis pour ajuster les fr quences basses le contr le MID pour ajuster les fr quences m diannes et le contr le HIGH pour les fr quences aigu s Contr le de Filtre Coupe Bande Le contr le...

Page 6: ...Num rique Les banques A et B contiennent au total 32 effets num riques pr r gl 16 pour chaque banque Le commutateur bank select situ au panneau avant permet de s lectionner la banque d effet d sir e L...

Page 7: ...everb Slow Flange 6 Reverb Two 1 2ms Room Reverb 2 5s Hall Reverb 7 Reverb Chorus Room Reverb Slow Chorus 1 8s Hall Reverb Med Chorus 8 Detuned Chorus Med Chorus Detuned Pitch Shift Slow Chorus Detune...