INSERT OPTIONAL EQUIPMENT (Continued)
4. Blower, Front (Continued)
3.
Insert one of the screws in each hole. Pull the blower assembly up as far as it will go to eliminate any
space between the blower and ashlip.
4.
Tighten both screws securely.
5.
Insert the plug into a grounded outlet.
FRONT BLOWER OPERATION
The blower controls are located on
the switch box that is connected by a
cord to the blower. There are two
rocker switches that determine the
speed and mode (automatic or
manual) of the blower. The two
speeds are RUN (slower) and
STARTUP (faster). The two modes
are AUTO (the thermodisk controls
the switch and the temperature of the
firebox will determine when the
blower starts or stops) and MAN
(manual Ð the blower will run on the
speed setting selected). The blower
should be switched "OFF" for
approximately 30 minutes after each
reload of the stove. This is to allow
the stove to reach operating
temperature.
Speed Control Rocker Switch
(If OFF is selected, the blower
will always be off, even if on
automatic)
Mode Rocker Switch (If OFF
is selected, the blower will
always be off, no matter what
the speed setting is at)
RUN OFF STARTUP
AUTO OFF MAN