6
Installation
(for qualified installers only)
© Travis Industries, Inc.
4110603
100-01265_000
Installation Warnings
!
Failure to follow all the requirements may result in property damage, bodily injury, or death.
!
This firepit must be installed by a qualified installer.
!
The requirements listed below are divided into sections. All requirements must be met
simultaneously. The order of installation is not rigid – the qualified installer should follow the
procedure best suited for the installation.
Consult Local Regulations
Consult
your
local
city
or
county
regulations
for
firepits
before
proceeding
with
installation.
Local
regulations
govern
building
and
using
firepits
on
private
and
public
property.
Some
cities
and
regions
require
a
burning
permit
before
starting
an
outdoor
fire,
and
seasonal
or
time
of
day
restrictions.
Some
firepit
regulations
dictate
the
type
of
materials
out
of
which
it
should
be
constructed.
Laws
may
also
govern
what
can
be
burned
in
a
firepit
or
how
ashes
are
disposed.
Placement Requirements
!
For Outdoor Use Only. Install only in well-ventilated areas.
Do
not
locate
the
firepit:
In
high
traffic
areas
Under
or
near
trees,
plants
and
buildings
where
debris
may
constantly
fall
into
the
firepit.
Excessive
debris
will
require
high
maintenance
and/or
cause
malfunctioning
of
the
firepit.
In
places
where
people,
children,
and
pets
may
contact
the
firepit.
Guards
or
fences
around
the
firepit
in
these
locations
are
recommended.
Clearances:
NOTE
:
All
clearances
are
measured
from
the
outside
edge
of
the
firepit.
The
distance
from
any
structure
or
combustible
material
to
the
firepit
perimeter
shall
be
a
minimum
of
25
ft.
(7.62
M).
Lesser
clearances
shall
be
used
only
where
acceptable
to
the
local
authority
having
jurisdiction.
The
distance
from
any
overhanging
foliage
(trees,
shrubs,
and
so
on)
to
the
firepit
shall
be
a
minimum
of
15
feet
(4.572
M).