![Travis Industries Freedom Bay Owner'S Manual Download Page 9](http://html1.mh-extra.com/html/travis-industries/freedom-bay/freedom-bay_owners-manual_1154114009.webp)
I
NSERT
I
NSTALLATION
(C
ONT
.)
P
AGE
7
I
NSERT
P
LACEMENT
R
EQUIREMENTS
(See the illustration below)
¥
The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,
doors), 36" of the front of the insert
¥
Insert and hearth must be installed on a level, secure floor
¥
Sidewalls must maintain a minimum 15" to the insert
¥
Non-combustible side facing must extend 13 1/2" from the insert
¥
Non-combustible top facing must extend 30" above the insert (17" with mantle shield)
¥
Mantle must be a minimum 32" above the insert (19" with mantle shield)
¥
Hearth must extend 16" in front of the faceplate
¥
Hearth must extend 8" from the sides of the insert
Combustible Mantle
Sidewall
Surround
Panels
B
* Measure from faceplate, does
not include the distance the insert
sticks out on the hearth (4 3/4").
**Total hearth width must be at
least 45 1/4"
Masonry
Fireplace
15"
13 1/2"
30"
17"
32"
19"
16"
8"
Minimum
C l e a r a n c e s
A Sidewall to Insert
B Side Facing
C Top Facing
With mantle shield
D Mantle to Insert
With mantle shield
E Hearth (Front)*
F Hearth (Side)**
F
Measure side
clearances
from here.
A
E
Non-Combustible
Facing
C
D
H
EARTH
R
EQUIREMENTS
(See the illustration above)
¥
Must extend 16" in front of the insert and 8" on both sides (total of 20 3/4" deep by 45 1/4" wide)
¥
Must be non-combustible and at least .018" thick (26 gage)
I
NSERT
S
IZE
R
EQUIREMENTS
* Older model panels may use the
heightened yoke, adding 7/8" to
the height. Furthermore,
additional room is needed to align
the pipe on positive and direct
connect installations.
Minimum
Fireplace Size
E
D
C
A
B
F
A Height* (front)
B Height* (rear)
C Width (front)
D Width (rear)
E Depth
F Hearth**
Masonry
Fireplace
21 3/4"
21 3/4"
29 1/4"
291/4"
15 3/4"
4 3/4"
** Does not include the required
16" of floor protection in front.