48
Optional Equipment
(for qualified installers only)
© Travis Industries
4091008
100-01236_000
4
Follow the directions below to replace the orifices.
Screw each LP orifice in so the
orifice protrudes 15/16" (24mm)
(indicating full insertion).
c
Look here for the orifice identification
Apply thread sealant to the LP
orifices prior to installation. Use
the chart below to identify the
correct orifices.
Front
Rear
NG
#49
#43
LP
#57
#53
b
1/2" Wrench
Use a 1/2" open end wrench
to unscrew the two orifices.
Front Burner Orifice
a
Rear Burner Orifice
15/16"
24mm
5
Install the new manifold cover included in owner’s pack (see illustration below).