Installation (for qualified installers only)
15
© Travis Industries
4091008
100-01236_000
Vent Location
A vent restrictor is built into the appliance to adjust the flow rate of exhaust gases. This ensures
proper combustion for all vent configurations. Depending upon the vent configuration, you may be
required to adjust the restrictor position.
2”
Center Line
Inlet (3” Dia.)
Exhaust (4” Dia.)
Fireplace
Opening
1-1/2”
4-1/2”
14-3/4”
5-1/8”
NOTE: Vent location changes based
upon restrictor position. Position # 1 is
shown to the right. Each restrictor
position moves the vent location forward
(toward the fireplace opening)
approximately 1/4”.
Vent Configurations
Z.C. (Metal) Wood-Burning Fireplace
Inlet & Exhaust Re-Line
Exhaust Only Re-Line
Direct Vent Cap
(part # 991)
Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.
6-5/8" to 3" & 4" Colinear
Adapter & Flashing
(Travis Part # 98900124)
A block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.
Block-Off Plate
(non-combustible
materials)
NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.
Inlet
Masonry Fireplace
Any cracks or
damage inside the
chimney must be
repaired.
Exhaust
4" dia.
Gas Liner
Inlet
3" dia. Gas Liner
Exhaust
4" dia. Gas Liner