Installation (for qualified installers only)
7
© Travis Industries
9/17/2020 - 1536
DVL EG GSR2
Installation Warnings
Failure to follow all of the requirements may result in property damage, bodily injury, or even death.
This heater must be installed by a qualified installer who has gone through a training program for
the installation of direct vent gas appliances.
The installation must conform with local codes or, in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the National Gas and Propane Installation Code, CSA
B149.1.
Manufactured or Mobile Homes must conform with Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for
Manufactured Home Installations, ANSI/NCSBCS A225.1. This appliance may be installed in
Manufactured Housing only after the home is site located.
The heater is designed to operate on natural gas, or propane (LP).
All exhaust gases must be vented outside the structure of the living area. Combustion air is drawn
from outside the living-area structure.
Notify your insurance company before hooking up this heater.
The requirements listed below are divided into sections. All requirements must be met
simultaneously. The order of installation is not rigid – the qualified installer should follow the
procedure best suited for the installation.
Packing List
Propane Conversion Kit (Orifices, Manifold
Cover, etc.)
Top Convection Deflector
"Fireplace Altered" tag (attach to the fireplace)
Plugs for Surround Panels
Remote
Control
Items Packed with the Face
Face with attachment hardware
Face Installation Instructions
Order of Installation
1. Run gas line to the fireplace
2. Remove the glass frame.
3. Run vent through fireplace chimney. On larger
fireplaces, the vent connector may be left in place. For
smaller fireplaces, remove the vent connector. See
“Vent Connector Removal and Installation” for details.
4. Place the insert into position and attach the gas line
and vent.
5. If converting to LP gas, Remove the burner and media
tray.
If not, skip this step
.
NOTE
: If using propane (LP), convert the appliance at
this time.
6. Install the firebacks (optional).
7. Replace the burner (if needed).
8. Install the media.
9. Install the surround panel (see instructions included
with surround panel).
10. Replace the glass.
11. Install the face (see instructions included with the face).
12. Follow the instructions under “Finalizing the
Installation.”
Additional Items Required
3" and 4” Diameter Gas Liner with Termination (Kit – sku# 96200340 or 96200331)
Gas Line Equipment (shutoff valve, pipe, etc.)
Panel
Kit
Media
(Logs)
Face