Installation
(for qualified installers only)
9
Travis Industries
4041206
1 0 0 - 0 1 1 4 7
Corner Installations
A typical 45° installation
uses the minimum framing
dimensions shown in the
illustration to the right
(NOTE: all clearances still
apply).
AAA
AAA
AA
AA
AA
A
A
A
A
A
A
A
A
A
A
A
AAAAAAAAAAA
19-3/8"
1" Standoffs
Min. 1" Clearance to
Fireplace Enclosure
47-5/8"
13-3/4"
14-3/4"
Raised Fireplaces
•
The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace
(250 Lbs.) and vent.
•
The fireplace may not be raised so as to place the ceiling within 36" of the base of the fireplace.
Raised fireplace
Raised fireplace with
raised hearth.
Raised
Platform
Nail the nail down plates to the floor
(or raised platform)
Raised Hearth
Hearth
Raised
Platform