Installation
(for qualified installers only)
2 7
Travis Industries
4041206
1 0 0 - 0 1 1 4 7
Electrical Connection
•
Make sure the household breaker is shut off prior to working on any electrical lines.
•
The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)
•
The electrical line must be 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)
•
Follow the directions below to connect power to the fireplace.
a
b
Insert the sheathed cable from the power source through
this cable clamp. Once the wires are attached, tighten
the clamp to secure the cable.
Replace
the cover
removed
in step "a".
Attach the common (white), ground (exposed or green) wires, and hot
(black) wires from the power source to the electrical connector (attached
to the fireplace).
c
d
Standard
Screwdriver
Remove the cover from the
fireplace junction box.
1/4" Nutdriver
Electrical
Connector
WARNING: Make sure power is
off from the power lead before
conducting any wiring.