18
Insert Installation
(for qualified installers only)
Travis Industries
93508133
4 020509
Insert Size Requirements (see Illustration below)
M i n i m u m
Fireplace Size
Masonry
Fireplace
Z.C. (Metal)
Fireplace
a
b
c
d
e
f
g
h
i
j
Height (front)
Height (rear)
Width (front)
Width (rear)
Depth
Hearth Depth*
Hearth Width
Facing Width
Facing Height
Mantel Height
21 1/2"
21 1/2"
23 3/4"
23 3/4"
11 3/8"
20 3/4"
39 3/4"
41 3/4"
39"
41"
21 1/2"
21 1/2"
25 3/4"
25 3/4"
12 3/8"
20 3/4"
39 3/4"
47 3/4"
31"
43"
a
c
e
f
b
d
h
i
j
g
Non-Combustible Hearth
Combustible Mantel
Non-Combustible Facing
* This is the distance the insert protrudes from
the fireplace opening plus the required 16" of
hearth extension.
Insert Placement Requirements
•
The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,
doors), 36" of the front of the insert
•
Insert and hearth must be installed on a level, secure floor
•
The minimum clearances, facing, and hearth requirements in the illustration below must be met
(follow the clearances for the type of fireplace being used - either masonry or zero-clearance).
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
AAAAAAAAAAAAAAA
Side
Wall
Combustible Mantel
Combustible Top Facing
Non-Combustible
Hearth
Facing
Masonry
Fireplace
Minimum Clearances
k
l
m
n
o
p
q
x
Sidewall to Insert
Side Facing
Top Facing
w. Mantel Shield
Mantel to Insert
w. Mantel Shield
Hearth (Front)*
Hearth (Side)
Front of Insert
Extension onto Hearth
10"
9"
20"
14 1/2"
22"
16 1/2"
16"
8"
36"
4 3/4"
* Does not include the distance the insert
extends onto the hearth (dimension "x").
q
l
k
p
x
o
n
m
ZC (Metal)
Fireplace
30"
12"
12"
n/a
24"
n/a
16"
8"
36"
4 3/4"
Hearth Requirements
•
Must extend 16" in front of the insert and 8" on both sides
•
Must be non-combustible 1/4" thick insulating board with a thermal conductivity of K = 0.72