Installation
(For Qualified Installers Only)
13
© Travis Industries
4/11/22- 1566
AGP Stove
Mobile Home Requirements
The stove must be vented using an approved listed pellet vent (sometimes referred to as “L” or “PL”
vent pipe).
The appliance, venting system, and hearth system (if applicable) must be installed in accordance with
the terms of their listing and their manufacturer’s instructions.
Outside Air Kit (sku# 99200139) must be used to duct combustion air directly into the appliance. The
kit is available through your dealer.
The stove must be secured to the floor of the manufactured home. Travis Industries manufactures a
kit (sku# 98900509) for securing the appliance. The kit is available through your dealer.
The appliance must be plugged into a properly grounded outlet.
DO NOT INSTALL IN SLEEPING ROOM.
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
Outside Air (Used for Combustion
Use Part #99200136)
Outside air is strongly recommended. The use of outside air reduces noise levels inside
the house and prevents smoke spillage into the home during power outages.
Must not be drawn from an enclosed space (garage, unventilated crawl space).
Must not be over 48” (1220mm) long
Must be made with 1-¾” (45mm) diameter or larger metal or aluminum duct with a metal screen
attached to the end to keep out rodents (P.V.C. or other combustible materials may not be used).
We recommend the Travis Industries Outside Air Kit (part # 99200136).
Must not terminate above or within 1' (305mm) of the chimney termination.
Must have a rain cap or down-turned elbow to prevent water from entering.
Must be located so that it will not become plugged by snow or other material.
1-3/4” Air Duct
A screen is required to prevent
animals from entering.
Outside air entrance must be placed so it
does not become blocked by snow.
Air may be drawn from a ventilated crawl space.