Wall Thermostat 

SKU 99300650 

 

Page 1 of 3 

2/2/11  -  17601040 

© Travis Industries, Inc.  

Compatibility 

 

All Travis Gas Stoves 

 

33 DVI Insert 

 

31 DVI Insert 

 

564 SS and DF 

 

864 TRV, ST, and HO 

 

All Travis Pellet Stoves or Inserts 

Packing List 

 Thermostat 

 

Thermostat Wire (20’) 

 

(2) Screws (for attaching thermostat) 

Installation Warnings 

!  Shut off power to the appliance and allow it to cool prior to installation. 

!  This kit must be installed by a qualified technician. 

!  Do not connect 110 VAC to the gas control valve or on/off switch on gas heaters or the thermostat 

posts on pellet heaters. 

Follow the instructions on the following pages for the type of model being addressed. 

Wire Connection - Pellet Heaters 

Attach the thermostat wire to the circuit board. 

b

Swing the 

panel 

open.

d

a

Phillips 

Screwdriver

Open the hopper lid and remove the 

screw holding the right panel in place.

Route the wires up to the circuit 

board and attach the quick-connects 

to the thermostat posts  (orientation 

does not matter).

Bundle up any excess wire with a 

lock-tie to prevent it from contacting 

any hot or moving parts

If necessary, attach the 

pellet stove connector 

wires to the ends of the 

receiver wires.

c

 