Fireplace Placement Requirements 

 

Fireplace must be installed on a level surface capable of supporting the fireplace and vent 

 

Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet) 

 

Fireplace should be located out of traffic and away from furniture and draperies. 

 

Fireplace must be placed so the gaps below and above the glass frame do not become blocked. 

 

Fireplace may be placed in a bedroom.  Please be aware of the large amount of heat this appliance 
produces when determining a location. 

Clearances 

(a)  Clearance to Side and Rear of Fireplace 0” (0mm) 

(b)  When installed, walls in front of the fireplace must be a minimum 5” (127mm) to the side of the 

fireplace.  Do not place insulation in this space. 

(c)  Clearance to Angled Sides of Fireplace ½” (12mm) 

 

Raised Fireplaces 

 

The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace 
and vent.   

 

The base of the fireplace must be a minimum 70” (1778mm) below the room ceiling. 

 

b

a

c

Summary of Contents for 864 HO NB GSR2

Page 1: ...LL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall b...

Page 2: ...Vent Configuration Horizontal Termination no vertical rise 21 Vent Configuration Horizontal Termination with vertical rise 22 Vent Configuration Vertical Termination 23 Termination Requirements 24 Hea...

Page 3: ...uctions refer to the 864 HO NB GSR2 Owner s Manual part 100 01411 Listing Details This appliance was listed by Intertek Test Labs to ANSI Z21 88 The listing label is attached to the appliance near the...

Page 4: ...nstalled in Manufactured Housing only after the home is site located All exhaust gases must be vented outside the structure of the living area Combustion air is drawn from outside the living area stru...

Page 5: ...g and maintenance instructions that you will need at a later time Always follow the instructions in this manual Instruct everyone in the house how to shut gas off to the appliance and at the gas main...

Page 6: ...s Propane Approximate Heating Capacity in square feet Up to 2 500 Up to 2 500 Maximum BTU Input Per Hour 46 700 46 700 Heating capacity will vary with floor plan insulation and outside temperature Dim...

Page 7: ...96100824 Brick Herringbone 96100825 Handmade Brick 96100826 Rock Creek 96100827 Black Enamel 96100828 Dia Stucco 96100829 Stainless Steel 96100832 Stainless 96100833 Black Enamel 96100834 Black Painte...

Page 8: ...uilding at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in pri...

Page 9: ...bove the glass frame do not become blocked Fireplace may be placed in a bedroom Please be aware of the large amount of heat this appliance produces when determining a location Clearances a Clearance t...

Page 10: ...10 Installation for qualified installers only Travis Industries 4140922 100 01410 Minimum Framing Dimensions Rear Vent a Minimum Enclosure Height 41 25 1048mm 48 1219mm 21 75 533mm 56 375 1432mm a...

Page 11: ...nimum Framing Dimensions Top Vent NOTE When the vent is routed vertically the framing must accommodate the vent and required 1 clearance The framing dimensions below reflect the additional 1 depth req...

Page 12: ...kets on both sides Secure the fireplace to the framing NOTE Make sure the fireplace is square and plumb when placed in the framing Measured corner to corner the fireplace should be square approx 54 7...

Page 13: ...nt Configuration A typical 45 installation uses the framing dimensions shown in the illustration below NOTE all clearances still apply NOTE When venting horizontally use minimum vent kit C 96200316 wi...

Page 14: ...ing of that system at test pressures in excess of 1 2 psig 3 5 kPA For pressures under 1 2 psig 3 5 kPA isolate the gas supply piping by closing the manual shutoff valve Leak test all gas line joints...

Page 15: ...Line to the Left Side 1 Disconnect the gas line from the shutoff valve 3 4 wrench Gas line is located inside the fireplace on the right side 2 Remove the screw that holds the shutoff valve plate in pl...

Page 16: ...rounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 The electrical line must be a min 14 ga...

Page 17: ...t an air shutter adjustment Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard Consult your dealer or installer if you suspect an improperly ad...

Page 18: ...ion for qualified installers only Travis Industries 4140922 100 01410 Vent Location and Vent Shield Position Make sure shield is at 45 deg 43 5 1105mm Make sure shield is at 90 deg 48 1035mm 18 458mm...

Page 19: ...are built into the appliance to adjust the flow rate of intake air and exhaust gases Depending upon the vent configuration you may be required to adjust the restrictor positions The charts for accept...

Page 20: ...20 Installation for qualified installers only Travis Industries 4140922 100 01410 Intake Restrictor closed 5 4 3 2 open stock position 1 b a Position 3 3 8 Wrench c...

Page 21: ...rizontally use minimum vent kit C 96200316 If venting from a corner installation an additional 45 elbow is required 45 Elbow Termination 3 feet 0 915m 0 feet 0 feet 4 max 1 22m Exhaust Restrictor 1 st...

Page 22: ...5 feet 1 5 m 10 feet 3 m 0 feet 15 feet 4 5 m 20 max 6 m 10 feet 3 m 15 feet 4 5 m 22 max 6 7 m 5 feet 1 5 m 0 feet 0 feet 20 feet 6 m 5 feet 1 5 m 10 feet 3 m 10 feet 3 m 15 feet 4 5 m 15 feet 4 5 m...

Page 23: ...al high wind cap 46DVA VCH Exhaust Restrictor 8 Intake Restrictor 3 5 feet 1 5m 0 feet 0 feet 5 feet 1 5m 0 feet 20 feet 6m 20 feet 6m 5 feet 1 5m 10 feet 3m 5 feet 1 5m 10 feet 3m 0 feet 15 feet 4 5m...

Page 24: ...floor NOTE Clearance in accordance with local installation codes and the requirements of the gas supplier G Minimum 48 1219mm clearance from any adjacent building H Minimum 84 2134mm clearance above a...

Page 25: ...ng the fireplace must be raised so the base of the unit is above the carpet surface or flooring material Floor Mounted Fireplaces Raised Fireplaces A hearth is not required when the fireplace is raise...

Page 26: ...tible may be placed above the non combustible facing see b below and to the sides and below the fireplace face This combustible facing must be a minimum 7 3 4 197mm above the face of the fireplace see...

Page 27: ...stible over 1 25mm thick see Thick Facing on page 32 Hearth Line Non combustible hearth facing should be installed up to this location 1 25mm above the base of the fireplace The fireplace may be raise...

Page 28: ...er grill deflectors to be removed See the instructions below Special Instructions for Wilmington Faces The above faces require the outer grill deflectors to be removed to allow for installation of the...

Page 29: ...faces require the inner grill deflectors to be removed See the instructions below Remove the four inner deflectors use needle nose pliers if necessary These tabs bend down to allow for removal Re atta...

Page 30: ...n air Raised Fireplaces Facing is installed 1 25mm maximum above the base of the fireplace Facing is installed to this edge of the fireplace FRONT VIEW Tile Line Tile Line Hearth Line Tile Line 34 1 4...

Page 31: ...Note how the facing extends 1 25mm above the base of the fireplace 1 25mm Fireplace Support Floor Tile or other facing under 1 25mm thick Face Floor Max 1 25mm Hearth note how it extends under the fa...

Page 32: ...Line Fireplace Drywall Framing Nailing Bracket Masonry TOP VIEW Protruding Masonry Fireplace Drywall or cement board etc Framing NOTE The nailing brackets are not used for this type of installation se...

Page 33: ...98500688 The template helps locate and support the masonry as it being installed Masonry Line Hearth Line Floor Mounted Fireplaces or Raised Hearths Build the hearth 1 25mm maximum above the base of t...

Page 34: ...e masonry extends 1 25mm above the base of the fireplace 1 25mm Fireplace Support Floor Floor Mounted Fireplace with Hearth SIDE OF FIREPLACE Masonry or other non combustible over 1 25mm thick Face Fl...

Page 35: ...rom the glass frame require a 5 127mm clearance to the side of the fireplace Combustible mantel columns legs that protrude 19mm or less from the glass frame must meet the facing clearances minimum 2 1...

Page 36: ...TE Take care to not touch the bulb with your fingers use a cloth or paper towel 4 Install the required firebacks see page 41 5 Install the burner and media logs or stones See the instructions included...

Page 37: ...ing and maintenance instructions refer to the Owner s Manual part 100 01253 ACID WASH WARNING Before installing the faceplate make sure any masonry that has been treated with acid wash has been proper...

Page 38: ...urer s barrier for this appliance If using a face or grill that requires use of a cove cover use the cove cover included with the fireplace see below Do not use the cover included with face or grill i...

Page 39: ...instructions included with the face for details Open the six latches holding the glass frame in place start with the bottom three follow the directions shown to the right a Lift the glass frame up an...

Page 40: ...rn when it is disengaged Follow the directions below to re install the latch if it becomes loose Top of Firebox Hold the latch at an angle and insert it into the slot on the glass frame anchor NOTE th...

Page 41: ...the firebacks following the directions below Place the rear fireback in place The side fireback holds the rear fireback in place hold the rear fireback while installing the side fireback Remove the cl...

Page 42: ...personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted app...

Page 43: ...ration below Screw each LP orifice in so the orifice protrudes 15 16 24mm indicating full insertion c Look here for the orifice identification Apply thread sealant to the LP orifices prior to installa...

Page 44: ...below a Use a 7 16 open end wrench to remove the pilot hood b Remove and discard the Natural Gas NG orifice Place the LP orifice in the pilot assembly then replace the pilot hood tightening the pilot...

Page 45: ...ENTED Secure using the screws included with the motor see Figure 2 tighten to 25 Lb inches Leak test this area after installation to verify proper installation Figure 1 Figure 2 8 Replace the burner P...

Page 46: ...allation 1 Remove the grate from the firebox Remove and discard the two andiron prongs see step a to the right NOTE The nuts do not need to be removed they can be loosened to remove the prongs 2 Attac...

Page 47: ...Purple Grey Pilot Sensor Spark Rod Comfort Control Valve Battery Box Manual On Off Accent Light s 3 Amp Fuse Optional Blower s 3 Amp Fuse Appliance Ground Accessory Power Appliance Ground Green Orange...

Page 48: ...ireplace Follow the directions included with the power heat duct for installation The wiring may be routed through a snap disc on the fireplace similar to the 864 HH NOTE This fireplace has a snap dis...

Page 49: ...Optional Equipment for qualified installers only 49 Travis Industries 4140922 100 01410 Remove the 2 screws on the power heat duct cover plate and remove the cover...

Page 50: ...Minimum Framing Dimensions Rear Vent 10 Minimum Framing Dimensions Top Vent 11 Nailing Brackets 12 National Fireplace Institute 3 Optional Faceplates Sizing Chart 28 Overview 3 Packing List 7 Power H...

Reviews: