II. RECEIPT INSPECTION 

All Traulsen products are factory tested for performance and are free 
from defects when shipped.  The utmost care has been taken in crating 
this product to protect against damage in transit.  

You should carefully inspect your unit for damage during delivery.  If 
damage is detected, you should save all the crating materials and 

make note on the carrier’s Bill Of Lading describing the damage.  A 

freight claim should be filed immediately.  If damage is subsequently 
noted during or immediately after installation, contact our customer 

care team to file a freight claim.  There is a fifteen (15) day limit to file 

freight damage with the carrier.  Under no condition may a damaged 
unit be returned to Traulsen without first obtaining written permission 

(return authorization).  You may contact Hobart/Traulsen customer care 

at 800-333-7447 to request a return or file a claim.

III. INSTALLATION

III. a - LOCATION:

Select a proper location for your unit, away from extreme heat or cold.  
Allow enough clearance between the unit and the side wall in order to 
make use of the stay open feature at 120

0

 (self-closing feature operates 

up to 90

0

).  The door(s) must be able to open a minimum of 90

0

 in order 

to make use of the maximum clear door width.

NOTE:  Do not install the cabinet without legs, casters or front 
ventilated utility base.

III. b - PACKAGING:

All Traulsen units are shipped from the factory bolted to a sturdy wooden 
pallet and packaged in a durable cardboard container.  The carton is 
attached to the wooden skid with the use of large staples.  These should 
first be removed to avoid scratching the unit when lifting off the crate.

To remove the wooden pallet, first if at all possible, we suggest that the 
cabinet remain bolted to the pallet during all transportation to the point 
of final installation.  The bolts can then be removed with a 5/8” socket 
wrench by tipping or otherwise raising the unit to allow access to them.  
Avoid laying the unit on its front, side or back for removal of the pallet.

NOTE:

  Traulsen does not recommend laying the unit down on 

its front, side or back.  However, if you must please be certain 
to allow the unit to remain in an upright position afterwards for 
24 hours before plugging it in so that the compressor oils and 
refrigerant may settle.

III. c - INSTALLING/ADJUSTING LEGS OR CASTERS:

6” High legs are supplied standard for all Traulsen compact undercounter 
and prep table units.  These are shipped from the factory inside a 
cardboard box which is secured inside the cabinet.  Casters in lieu of 
legs are supplied as an optional accessory for all compact undercounter 
and prep table models.  

III. INSTALLATION (CONTINUED)

III. c - INSTALLING/ADJUSTING LEGS OR CASTERS: 

(continued)

The casters are “stem” type, and do not require the use of any bolts.  When ordered 
casters are shipped in a separate box.

WARNING: THE CABINET MUST BE BLOCKED AND STABLE BEFORE INSTALL-
ING LEGS OR CASTERS.

Raise up and block the cabinet a minimum of 7” from the floor and thread the 
legs into the threaded holes on the bottom of the cabinet’s.

 

Thread optional casters into the threaded holes on the bottom of the cabinet in 
the same way.  Casters with brakes should be installed at the front.

Level the cabinet using a level or pan of water in the bottom of the cabinet.  On 
units with legs, turn the adjustable feet in or out to level the cabinet side-to-side 
and front-to-back.  Units with casters should be placed on level floors.

NOTE:  Traulsen units are not designed to be moved while on legs.  If the unit 
requires moving, a pallet jack or forklift should be used to prevent damage.

Summary of Contents for UHT Series

Page 1: ...er found on the name tag affixed to the unit Should you need service call us on our toll free number 800 825 8220 between 7 30 am 4 30 pm CST Monday thru Friday You may also log onto www traulsen com for further information It is our pleasure to help and assist you in every possible way OWNER S MANUAL Instructions for the installation operation and maintenance of Traulsen FORM NUMBER TR35746 REV 1...

Page 2: ...Preparing For Extended Shut Down Page 6 c Adjusting The Door Page 6 d Door Drawer Gasket Replacement Page 7 VII TROUBLE SHOOTING GUIDE Page 7 VIII SERVICE ASSISTANCE a Service Information Page 8 b Service Support Information Page 8 c Warranty Registration Page 8 IX WARRANTIES Page 9 X SERVICE PARTS LIST Page 10 11 I THE SERIAL TAG a Reading The Serial Tag Page 1 II RECEIPT INSPECTION Page 2 III IN...

Page 3: ...ble we suggest that the cabinet remain bolted to the pallet during all transportation to the point of final installation The bolts can then be removed with a 5 8 socket wrench by tipping or otherwise raising the unit to allow access to them Avoid laying the unit on its front side or back for removal of the pallet NOTE Traulsen does not recommend laying the unit down on its front side or back Howev...

Page 4: ...supplied with a cord and plug include a special three prong grounding plug on the service cord Select only a dedicated electrical outlet with grounding plug for power source NOTE Do not under any circumstances cut or remove the round grounding prong from the plug or use an extension cord III f POWER SUPPLY The supply voltage should be checked prior to connection to be certain that proper voltage f...

Page 5: ...on site to do so please follow the directions below 1 Peel Off backing and install foam tape provided around entire perimeter of the top of the unit 2 A flange is assembled underneath at the front of the counter top This flange has two screw holes Screw the two 1 4 20x5 8 screws provided through the holes in this front flange into the threaded holes in the front of the top edge of the unit 3 Using...

Page 6: ...cycle will start in about 5 hours 40 minutes On all models ULT27 ULT48 and ULT60 the defrost time control is located on the front side of the evaporator housing behind the temperature control adjustment screw On earlier models ULT48 and ULT60 the defrost time control was accessed through a small round opening on the outside rear of the unit ULT32 freezer model requires no adjustment The defrost oc...

Page 7: ...p hinge bracket The hinge plate pin and plastic bushing will remain in the top hinge plate Lay the door down on a padded flat surface while being careful not to allow the lower hinge plate and mechanism stem to slide out the bottom of the door NOTE The lower hinge plate is under spring tension Grasp the lower hinge plate while keeping a firm grip on the plate carefully slide it out the bottom of t...

Page 8: ...for the cabinet to recover its normal operating temperature b Adjust the thermostat to a warmer setting 5 Condensation on exterior surface a Check door s or drawer s alignment and gaskets for proper seal b Condensation on the exterior surface of the unit is perfectly normal during periods of high humidity 6 Compressor hums does not start a Call for service VII TROUBLE SHOOTING GUIDE 7 VI d DOOR DR...

Page 9: ...orth facility by phone at 800 825 8220 or fax to 817 740 6748 parts or 817 740 6757 service Note When calling for spare parts or service support please make sure you have model and serial number of unit available To source service support locally follow instructions below for nearest authorized service agent Please note you will be required to register for a login name and pass code to access our ...

Page 10: ...SEN warrants to the original purchaser the Refrigeration Equipment shall be manufactured free from defects in material and workmanship under normal use and service for a period of one 1 year from date of shipment Under this warranty TRAULSEN will reimburse the purchaser for the replacement of any part of said equipment excluding dryers refrigerant gas which then proves to be defective This warrant...

Page 11: ...ELF 27 MODELS SHELF CPW1 SHELF 32 MODELS SHELF CPW2 SHELF 48 MODELS UPPER SHELF48 UPPER SHELF 48 MODELS LOWER SHELF48 LOWER SHELF 60 MODELS UPPER SHELF60 UPPER SHELF 60 MODELS LOWER SHELF60 LOWER SHELF CLIP SHELF CLIP ALL MODELS SER 60269 00 THERMOMETER THERMOMETER ALL MODELS SER 60268 00 TOP BACKSPLASH BACKSPLASH TOP 27 MODELS CU27TOP BSWO BACKSPLASH TOP 32 MODELS CU32TOP BSWO BACKSPLASH TOP 48 M...

Page 12: ...ASSEMBLY TOP BOTTOM 550 10209 01 DRAWER SUPPORT LEFT 550 10231 00 DRAWER SUPPORT RIGHT 550 10232 00 DRAWER SLIDING RAIL LEFT 550 10230 00 DRAWER SLIDING RAIL RIGHT 550 10230 01 DRAWER CROSSRAIL 550 10223 00 DRAWER GASKET TOP 341 60099 04 DRAWER GASKET BOTTOM 341 60099 05 DRAWER ROLLER 344 41808 01 DIVIDER NARROW 701 61258 03 DIVIDER WIDE 701 61258 04 DRAWER 60 COMPACT DRAWER ASSEMBLY FIRST OPENING...

Page 13: ...NOTES ...

Page 14: ...ERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration 2013 Traulsen All Rights Reserved Traulsen 4401 Blue Moud Road Fort Worth TX 76106 Phone 800 825 8220 Fax 817 740 6757 Website www traulsen com ...

Reviews: