VII. SPECIALTY PRODUCTS - PROOFER/PROOFER RETARDER MODELS

 (cont’d)

VII. d - RETARDER OPERATION (cont’d):
MANUAL OPERATION - The Traulsen proofer retarder
can also be used in either PROOF or RETARD mode,
regardless  of  what  the  24-hour  timer  is  set  for.    By
switching manually to PROOF or RETARD, the cabi-
net can be run as needed without disturbing the pre-
set schedule you have the 24-hour timer set for.

VII. e - CARE OF WATER TANK & HEATING ELEMENTS:
The automatic flush system on the Traulsen proof cabi-
net will help minimize the amount of cleaning neces-
sary to maintain an accurate and consistent operation
of this cabinet.  Because water conditions vary from
location to location, we recommend that the tank cover
be removed and the interior of the water tank, along
with the heating elements, be cleaned with a soft ny-
lon bristled brush.  We recommend cleaning twice a
year or as conditions dictate.  Replace tank cover be-
fore placing proof cabinet back into operation.  If your
area has extremely hard water, a local water treatment
expert  should  be  consulted.    It  is  important  to  note
that after treatment the water should not be deionized.
A simple zeolite conditioner is usually the best sys-
tem.    Use  of  an  in-line  cartridge  will  reduce  the  fre-
quency of cleaning the heating coil, but remember to
frequently replace the cartridge.

VII. f - INTERIOR ARRANGEMENTS:
Traulsen proofer and proofer retarder models are de-
signed to accommodate roll-in bakery racks.  See be-
low for size and capacities.

Model PRI132H can accommodate one (1) roll-in rack
with a maximum size, with wheels inboard of frame, of
27” wide by 29” deep by 72” high.

Model PRI232H can accommodate two (2) standard 18”
x 26” pan racks or two (2) 23” x 23” donut screen racks.

Model PRI332H can accommodate three (3) standard
18” x 26” pan racks or two (2) 23” x 23” donut screen
racks.

Model PRR232HUT can accommodate two (2) standard
18” x 26” pan racks or two (2) 23” x 23” donut screen
racks.

The Proofer/Retarder Control

The Proofer Control

White

“Thermostat

Indicator”

Light

Green

“Water Level”

Light

WATER
LEVEL

BLOWER

   ON                    OFF

CONTROL

TEMP

OFF

 TEMPERATURE  PM   TIME

FLUSH

FLUSH   MINUTE

HOUR

Traulsen

HUMIDISTAT

102.5 F       11:30

LOWER LEVEL

TROUBLE

Amber

“Lower Level”

Light

Red

“Trouble”

Light

White

“Humidistat

Indicator”

Light

Thermostat

Flush Time

&

Time of Day

Adjustment

Ports

Humidistat

Control

Blower

ON/OFF

Switch

Blower

Power

Switch

“Flush

Indicator”

Light

Green

“Water Level”

Light

White

“Humidistat

Indicator”

Light

Amber

“Lower Level”

Light

White

“Thermostat

Indicator”

Light

Thermostat

Flush Time

&

Time of Day

Adjustment

Ports

Humidistat

Control

Delay

Bypass

Switch

Mode

Switches

OFF

HUMIDISTAT

 TEMPERATURE  PM   TIME

FLUSH

FLUSH   MINUTE

HOUR

Traulsen

102.5 F       11:30

DELAY

BYPASS

 ON                            OFF

CONTROL

Red

“Trouble”

Light

Summary of Contents for Traulsen Quality Refrigeration

Page 1: ...al number found on the name tag affixed to the unit Should you need service however call us on our toll free number 800 825 8220 between 7 30 am and 4 30 pm CST Monday thru Friday It is our pleasure t...

Page 2: ...Water Tank Heating Elements Page 8 f Interior Arrangements Page 8 VIII EVEN THAW MODELS a Application Overview Page 9 b Product Loading Guidelines Page 9 c Starting An Even Thaw Cycle Page 9 d Conclu...

Page 3: ...en carefully secured and the legs or casters are boxed and strapped inside to prevent damage Door keys will be attached to the handle with a nylon strip The handle is protected by an easily removable...

Page 4: ...cabinets set on the floor require the floor area to be flat and level In addition after the cabinet is set in place sealant should be used around the perimeter of the base to comply with National San...

Page 5: ...M Refer to the wiring diagram for any service work per formed on the unit Should you require one please contact Traulsen Service at 800 825 8220 and pro vide the model and serial number of the unit in...

Page 6: ...t or by filling out the on line warranty registration form located on the Technical Ser vice page of our website www traulsen com 5 IV CARE MAINTENANCE cont d IV b HINGE REPLACEMENT door units the top...

Page 7: ...once every 24 hours The operator should select a flush time when the unit is not proof ing This unit displays the time of day and temperature of the unit simultaneously When the proofer is activated...

Page 8: ...go from RETARD directly into PROOF This is accom plished by placing the delay bypass switch in the ON position VII d RETARDER OPERATION cont d AUTOMATIC MODE 24 HOUR TIMER The Traulsen proofer retarde...

Page 9: ...ing coil but remember to frequently replace the cartridge VII f INTERIOR ARRANGEMENTS Traulsen proofer and proofer retarder models are de signed to accommodate roll in bakery racks See be low for size...

Page 10: ...t will automatically switch to the Even Thaw mode disabling the compressor and enabling the heater If the doors are not left open too long during the loading stage this automatic switch ing to Even Th...

Page 11: ...UCTS EVEN THAW MODELS cont d VIII f FREQUENTLY ASKED QUESTIONS cont d Q What happens if we lose electrical power during the EvenThaw process A The unit will return to operation in refrigeration mode w...

Page 12: ...EFROST The cabinet has been shipped from the factory with three 3 timeclock defrost settings 12 midnight 8 a m and 4 p m For proper operation of the defrost sys tem it is imperative that the timeclock...

Page 13: ...rge quantity of warm food has recently been added or the door was kept open for a long period of time in both cases allow adequate time for the cabinet to recover its normal operating temperature 4 Fo...

Page 14: ...T OF OR WITH RESPECT TO THE EQUIPMENT OR ITS SALE OPERATION OR USE AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT...

Page 15: ...r 6 Humidistat Indicator Light 7 Humidity Control 6 I Ice Crushed 10 Inlet Strainer 6 J K L Legs 2 Louver Assembly 5 Lower Level Indicator Light 7 M Mode Lights 7 N O OFF Pin 7 ON Pin 7 Oxidation 11 P...

Page 16: ...Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST EXTENDED WARRANTY SERVICE HOURS Monday thru Friday 4 30...

Reviews: