VII. SPECIALTY PRODUCTS - PROOFER/PROOFER RETARDER MODELS

 (cont’d)

VII. c - OPERATING THE DIAL HUMIDISTAT (cont’d):
When the desired temperature and humidity settings
are achieved, the white mode indicating lights will go
OFF and you are now ready to proof your product.  The
mode lights indicate the various stages of operation
during the proofing process.

AMBER - “LOWER LEVEL” Will be illuminated during
normal operation.  Will only turn off when heater wa-
ter level is below minimum safety level or at start-up.

WHITE  -  “THERMOSTAT”  Will  be  illuminated  when
cabinet  is  not  at  set  temperature.    When  cabinet
achieves set temperature, the light will turn off.

RED - “TROUBLE” Will illuminate whenever the water
level is below minimum safe level.  It will also be on at
start-up for approximately 30 seconds.  When the red
light  illuminates,  power  to  the  heaters  is  turned  off.
This light is also lit during the flush period until the
units water level returns to normal.

GREEN  -  “WATER  LEVEL”  Will  be  illuminated  when
the water pan is full.  This light will turn off when the
solenoid valve opens to replenish the water pan.

WHITE - “HUMIDISTAT” Will be illuminated when cabi-
net is not at set humidity.  When the cabinet reaches
the set point this light will turn off.

VII. d - RETARDER OPERATION:
Additional  control  features  for  use  with  model
PRR232HUT only.

RETARD MODE: When in retard mode, the refrigera-
tion system will maintain the cabinet temperature be-
tween 35

°

 to 40

°

 F.  This temperature can be adjusted

through use of the temperature control, located inside
the unit mounted on the front of the evaporator coil
housing.  To lower the cabinet temperature, turn the
control knob clockwise.  To raise the temperature, turn
the knob counter-clockwise.

TIME DELAY: The Traulsen proofer/retarder cabinet is
supplied equipped with a time delay.  When the unit is
in automatic operation, this time delay shuts the unit
down for up to one hour when switching from RETARD
to PROOF mode.  This allows the cabinet to gradually
rise  in  temperature  before  the  air  and  water  heaters
come on.

For the best performance, it is recommended that this
time delay be used.  However, a time delay override
allows the user to bypass the relay, and the unit will
go from RETARD directly into PROOF.  This is accom-
plished by placing the delay bypass switch in the “ON”
position.

VII. d - RETARDER OPERATION (cont’d):
AUTOMATIC  MODE/24  HOUR  TIMER  -  The  Traulsen
proofer retarder cabinet is designed to allow both au-
tomatic  and  manual  operation.    With  the  function
switch in the “AUTO” position, a 24-hour timer auto-
matically  switches  between  PROOF  and  RETARD
modes at preset times daily.

To set these switching times, carefully pull the front
protective cover (clear plastic) from the timer, which
is  located  on  the  front  panel.    These  should  be  one
green “ON” pin and one red “OFF” pin on the timer
dial,  as  well  as  two  spares  for  each  in  the  top  right
hand corner.  Simply pull the red “OFF” pin from the
outside ring of the dial and place it in the position cor-
responding to the time that the cabinet should switch
out of RETARD.  NOTE: White portion of the dial cor-
responds to daytime hours; black portion corresponds
to nighttime hours.

If the time delay is not bypassed, the cabinet will go
into  a  waiting  period  and  then  switch  into  PROOF
mode.  Therefore, the “OFF” pin should be set at least
one hour and thirty minutes before the cabinet is ready
to proof.  Of course, this will vary with conditions and
the user should find the best time for application.

The “ON” pin should be placed at the time when the
unit should switch out of PROOF.  When the pressure
in the refrigeration system is in the operating range,
the  system  will  start  and  soon  come    down  to  stan-
dard retarding temperatures ( 37

°

 to 42

°

 F).  The time

necessary  for  this  function  of  operating  conditions
(proof  temperature,  room  temperature,  etc.)  and  will
vary.

Once  both  pins  have  been  properly  placed,  set  the
correct time of day.  This is accomplished by turning
the center knob clockwise until the correct hour is in-
dicated at the white marker in the left-hand corner.  Now
adjust for correct minutes, which are indicated by the
pointer in the interior cut out on the dial.  The timer
runs independent of the control circuits, and should
only need adjustment in the event of a power failure.

TO SET THE UNIT FOR AUTOMATIC OPERATION:

1. Set the 24-hour timer for the correct time of day
2. Set pins for desired switching times on 24-hour time
3. Choose time delay bypass; “ON” or “OFF”
4. Set mode switch for “AUTO”
5. Set desired proof temperature and humidity
6. Place control switch in the “ON” position

The unit will now run automatically.

Summary of Contents for Traulsen Quality Refrigeration

Page 1: ...al number found on the name tag affixed to the unit Should you need service however call us on our toll free number 800 825 8220 between 7 30 am and 4 30 pm CST Monday thru Friday It is our pleasure t...

Page 2: ...Water Tank Heating Elements Page 8 f Interior Arrangements Page 8 VIII EVEN THAW MODELS a Application Overview Page 9 b Product Loading Guidelines Page 9 c Starting An Even Thaw Cycle Page 9 d Conclu...

Page 3: ...en carefully secured and the legs or casters are boxed and strapped inside to prevent damage Door keys will be attached to the handle with a nylon strip The handle is protected by an easily removable...

Page 4: ...cabinets set on the floor require the floor area to be flat and level In addition after the cabinet is set in place sealant should be used around the perimeter of the base to comply with National San...

Page 5: ...M Refer to the wiring diagram for any service work per formed on the unit Should you require one please contact Traulsen Service at 800 825 8220 and pro vide the model and serial number of the unit in...

Page 6: ...t or by filling out the on line warranty registration form located on the Technical Ser vice page of our website www traulsen com 5 IV CARE MAINTENANCE cont d IV b HINGE REPLACEMENT door units the top...

Page 7: ...once every 24 hours The operator should select a flush time when the unit is not proof ing This unit displays the time of day and temperature of the unit simultaneously When the proofer is activated...

Page 8: ...go from RETARD directly into PROOF This is accom plished by placing the delay bypass switch in the ON position VII d RETARDER OPERATION cont d AUTOMATIC MODE 24 HOUR TIMER The Traulsen proofer retarde...

Page 9: ...ing coil but remember to frequently replace the cartridge VII f INTERIOR ARRANGEMENTS Traulsen proofer and proofer retarder models are de signed to accommodate roll in bakery racks See be low for size...

Page 10: ...t will automatically switch to the Even Thaw mode disabling the compressor and enabling the heater If the doors are not left open too long during the loading stage this automatic switch ing to Even Th...

Page 11: ...UCTS EVEN THAW MODELS cont d VIII f FREQUENTLY ASKED QUESTIONS cont d Q What happens if we lose electrical power during the EvenThaw process A The unit will return to operation in refrigeration mode w...

Page 12: ...EFROST The cabinet has been shipped from the factory with three 3 timeclock defrost settings 12 midnight 8 a m and 4 p m For proper operation of the defrost sys tem it is imperative that the timeclock...

Page 13: ...rge quantity of warm food has recently been added or the door was kept open for a long period of time in both cases allow adequate time for the cabinet to recover its normal operating temperature 4 Fo...

Page 14: ...T OF OR WITH RESPECT TO THE EQUIPMENT OR ITS SALE OPERATION OR USE AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT...

Page 15: ...r 6 Humidistat Indicator Light 7 Humidity Control 6 I Ice Crushed 10 Inlet Strainer 6 J K L Legs 2 Louver Assembly 5 Lower Level Indicator Light 7 M Mode Lights 7 N O OFF Pin 7 ON Pin 7 Oxidation 11 P...

Page 16: ...Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST EXTENDED WARRANTY SERVICE HOURS Monday thru Friday 4 30...

Reviews: