Project
Quantity
Item #
Model Specified:
CSI Section 11400
TRAULSEN
4401 BLUE MOUND RD.
FT. WORTH, TX 76106
PHONE 1 (800) 825-8220
FAX-MKTG. 1 (817) 624-4302
Website: www.traulsen.com
SECTION
6-3
Construction, Hardware and Insulation
Exterior sides, front, rear, door and interior are constructed of heavy gauge
stainless steel. The exterior top and bottom are constructed of heavy gauge
galvanized steel. The interior floor is constructed of stainless steel and insulated with
3
⁄
4
"
of resilient cork. Door(s) are equipped with guaranteed for life cam lift hinges with
stay open feature at 120
°
. Guaranteed for life, work flow handle is mounted
horizontally over recess in door which limits protrusion from door face into aisle ways.
Door is standard with cylinder lock. Easily removable for cleaning, vinyl magnetic
gasket assures tight door seal. Anti- condensate heater is located behind door
opening. Door is hinged left as supplied standard. Both cabinet and door are
insulated with high density, non-CFC foamed in place polyurethane.
Refrigeration System
Dual refrigeration systems are utilized in order to prevent short cycling, providing for
energy efficient operation and maximizing compressor life. These combine their
efforts through a unique air circulation system within the food zone. During Blast
Chill cycles both systems are in full operation. At the completion of any chill or freeze
cycle, one refrigeration system remains in use to maintain proper refrigerated
storage temperatures. Each unit requires a separate 4 HP remote condensing unit
for blast chill operation, and a floor drain or optional condensate evaporator for
condensate removal.
Blast Chill Operation
In Blast Chill mode both refrigeration systems, as well as four blowers are in
operation. Cabinet air temperature can be as low as 0
°
F. The control closely
monitors both the air and product temperatures to assure rapid chilling without
freezing. The operator is notified upon completion of each chill cycle, and the unit
automatically begins to maintain proper refrigerated storage temperatures. All chill
cycle data is then stored in memory and can either be printed or downloaded to a PC
on demand.
Controller
The SmartChill
®
microprocessor system operates using a familiar
"
ATM
"
type
interface, providing for ease of training and use. The control allows the chiller to be
operated in any one of three different chilling functions, and in any one of three
modes. HACCP documentation is facilitated by two on-board printers which record
all required product chill cycle information. This same data can also be downloaded
to a PC using optional SmartChill
®
communications software (available from Traulsen)
or via optional NAFEM Data Protocol Compliant hardware and software (by others).
An instructional DVD is included.
Roll-In Racks
Readily removable,
interior mounted stainless steel guides for rack are provided.
Maximum rack size with wheels inboard of frame is 27
"
wide by 29
"
deep by 72
"
high.
Racks are typically supplied by others, however these may be purchased directly
from Traulsen as an option.
Warranties
The standard warranty is a one year parts and labor warranty on all components and
the cabinet, and an additional four year parts only warranty on the
3
⁄
4
HP maintenance
compressor. Additional warranties are available at extra cost.
An on-site service validation is provided by an authorized agent at no-charge upon
installation in order to insure proper operation.
Specifications
Continued product development may necessitate specification changes without notice.
Part No. TR35799 (revised 1/07)
RBC200
RBC200RT
DIMENSIONAL DATA
Roll-In
Roll-Thru
Net Capacity cu. ft.
35 (990.5 l)
35 (990.5 l)
Number of Pans 12
"
x 20
"
x 2
1
⁄
2
"
26
26
# of Pans Depends Upon Rack Purchased
Rack Capacity (see
"
Roll-In Racks
"
)
1
1
Length Overall in.
48
1
⁄
2
(123.2 cm)
48
1
⁄
2
(123.2 cm)
Depth - Cabinet Only in. / Over Body in.
34 (86.4 cm)
34 (86.4 cm)
Depth - with Door Open 90
°
in.
65
1
⁄
8
(165.4 cm)
96
1
⁄
4
(244.5 cm)
Depth - Overall in.
37
1
⁄
2
(95.3 cm)
41
1
⁄
8
(104.5 cm)
Clear Door Width in.
27
1
⁄
4
(69.2 cm)
27
1
⁄
4
(69.2 cm)
Clear Door Height in.
72
5
⁄
8
(184.5 cm)
72
5
⁄
8
(184.5 cm)
Height - Overall in.
89
1
⁄
2
(227.3 cm)
89
1
⁄
2
(227.3 cm)
ELECTRICAL DATA
Voltage
115/60/1
115/60/1
Feed Wires with Ground
3
3
Full Load Amperes
15.2
15.2
Minimum Circuit Ampacity
20
20
Wattage
1725
1725
REFRIGERATION DATA
Holding System Only
Refrigerant
R404a
R404a
BTU/HR - HP -
3
⁄
4
HP Holding Compressor
3880
3880
Heat Load - BTU/HR
7000
7000
Suction Line in.
3
⁄
8
(.95 cm)
3
⁄
8
(.95 cm)
Liquid Line in.
1
⁄
4
(.63 cm)
1
⁄
4
(.63 cm)
REMOTE CONDENSER
(Note: all models require a remote condenser unit. For additional
technical support on optional remote condenser units consult factory.
REFRIGERATION DATA
RBC200
RBC200RT
Refrigerant
R404a
R404a
Voltage
208-230/60/1
208-230/60/1
Recommended BTU/HR - HP
18,700 - 4 HP
18,700 - 4 HP
BTU’s are rated at 90
°
F ambient and a -10
°
F evaporator temp.
Suction Line in.
7
⁄
8
(2.2 cm)
7
⁄
8
(2.2 cm)
Ref. Lines at Blast Chill Unit
Liquid Line in.
1
⁄
2
(1.3 cm)
1
⁄
2
(1.3 cm)
Ref. Lines at Blast Chill Unit
Suction Line in.
1
1
⁄
8
(2.9 cm)
1
1
⁄
8
(2.9 cm)
Ref. Line on Remote Condenser
Liquid Line in.
1
⁄
2
(1.3 cm)
1
⁄
2
(1.3 cm)
Ref. Line on Remote Condenser
NOTE
Figures in parentheses reflect metric equivalents
Equipped With One NEMA 5-20 P Plug
NOTE: Full load amps and plug style may vary depending
on electrical options chosen and condensing unit employed.
*REMOTE COMPRESSOR NOTES:
1 - See spec sheet 6-5 for remote compressor specifications.
2 - Remote compressor installation required by others. Traulsen provides an
service agent validation upon completion of remote system installation at no-
charge (call 800-825-8220 in order to arrange this).
3 - Remote compressor includes a five year warranty if purchased from Traulsen.