-10-
VI. CONTROL BASICS (continued)
VI. e - TECHNICAL DATA
Power supply
TRL-002....W 100-240Vac ±10%, 50/60Hz, 3W
Relay output max loads (240Vac)
TRL-002..S/T..-.
TRL-002..Q/R..-.
Compressor
16A resistive
12 FLA 48 RLA
12A resistive
12 FLA 48 RLA
Evap. Fan
16A resistive
4 FLA 12 RLA
8A resistive
4 FLA 12 RLA
Defrost
16A resistive
4 FLA 12 RLA
16A resistive
4 FLA 12 RLA
Auxiliary loads 1
7A resistive
7A resistive
Auxiliary loads 2
7A resistive
7A resistive
Input
NTC 10KΩ@25°C
LAE Part No. SN4...
Measurement Range
<0.5 within the measurement range
Operating Conditions
-10... +50°C; 15%...80% r.H.
CE (Approvals and Reference Norms)
EN60730-1; EN60730-2-9; EN55022 (Class B); EN50082-1