Replacing the UV-C Lamp
Replacing the UV-C Lamp— 6 to 9 months
The UV-C lamp has an average life span of 5000 hours of operation. Al-
though the lamp may illuminate, it will not perform effectively for disease
control. Lamp should be replaced before it expires.
You can check the status of the lamp by an illuminated blue color at the bot-
tom of the NanoZapp™.
.
Step 1: Twist off black quartz sleeve cover (counter clockwise)
Step 2: Gently pull quartz sleeve out.
Step 3: Unplug the UV-C lamp and plug in new lamp.