Safety Information

The signs below might be in the user manual, labeling or other component. 

They are the requirement of standard and using.

Symbol for “THE OPERATION 

GUIDE MUST BE READ”

Symbol for “MANUFACTURER”

Symbol for “SERIAL NUMBER”

Symbol for “TYPE BF APPLIED 

PARTS”

Symbol for “DIRECT CURRENT”

Symbol for “ENVIRONMENT 

PROTECTION - Electrical waste 

products should not be disposed of 

with household waste. Please recycle 

where facilities exist. Check with your 

local authority or retailer for recycling 

advice”

Symbol for “MANUFACTURE 

DATE”

Features:

 

Maximum 60 records per each user

General Description

For indoor use only

F1

T1A/250V Φ3.6*10CCC

Symbol for “Class II Equipment”

3rd technonoly: Measuring during inflation 

73mm×49 mm Blue LCD display with white backlight 

Indications for Use

Measurement Principle

   This product uses the Oscillometric Measuring method to detect blood pressure. 

Before every measurement, the unit establishes a “zero pressure” equivalent to the air 

pressure. Then it starts inflating the arm cuff, meanwhile, the unit detects pressure 

oscillations generated by beat-to-beat pulsatile, which is used to determine the systolic 

and diastolic pressure, and also pulse rate.

    The device also compares the longest and the shortest time intervals of detected 

pulse waves to mean time interval then calculates standard deviation. The device will 

display a warning signal with the reading to indicate the detection of irregular heartbeat 

when the difference of the time intervals is over 25%.

Caution: These notes must be 

observed to prevent any damage 

to the device.

SN

    Thank you for selecting TRANSTEK arm type blood pressure monitor 

(TMB-1597-BN). The monitor features blood pressure measurement, pulse rate 

measurement and the result storage. The design provides you with two years of 

reliable service.

    Readings taken by the TMB-1597-BN are equivalent to those obtained by a trained

observer using the cuff and stethoscope auscultation method.

    This manual contains important safety and care information, and provides

step by step instructions for using the product.

    Read the manual thoroughly before using the product.

   The Transtek Blood Pressure Monitor is digital monitors intended for use in measuring 

blood pressure and heartbeat rate with arm circumference ranging from 22 cm to 32 cm 

( about 8¾˝-12½˝ ) or 22cm to 42cm(about 8¾˝-16½˝).

It is intended for adult indoor use only.

The Bluetooth Combination Mark

Symbol for “Including RF

transmitter”

Contraindications

This device is contraindicated for any person who is connected to a wearable or 

implantable electronic device or instrument, such as a pacemaker or defibrillator.

This blood pressure monitor is not intended to be a diagnostic device.

Contact your physician if hypertensive values are indicated.

2

3

INTRODUCTION

INTRODUCTION

Summary of Contents for TMB-1597-BN

Page 1: ...Monitor TMB 1597 BN Please do read the user manual carefully and thoroughtly so as to ensure the safe usage of this product and keep the manual well for further reference in case you have problems Guangdong Transtek Medical Electronics Co Ltd Zone B No 105 Dongli Road Torch Development District Zhongshan 528437 Guangdong China ...

Page 2: ... DATA MANAGEMENT 18 Recall the Records Delete the Records INFORMATION FOR USER 21 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 23 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Irregular heartbeat detector Why does my blood pressure fluctuate throughout the day Why do I get a different blood pressure at home compared to the hospital I...

Page 3: ...e interval then calculates standard deviation The device will display a warning signal with the reading to indicate the detection of irregular heartbeat when the difference of the time intervals is over 25 Caution These notes must be observed to prevent any damage to the device SN Thank you for selecting TRANSTEK arm type blood pressure monitor TMB 1597 BN The monitor features blood pressure measu...

Page 4: ... of ME EQUIPMENT The plug adapter plug pins insulates the device from the main supply Do not position the device in a position where it is difficult to disconnect from the supply mains to safely terminate operation of ME EQUIPMENT Before every use check the device do not use the device or an electrode if it is damaged in any way The continuous use of a damaged unit may cause injury improper result...

Page 5: ...and transmit the measuring results for User 2 Component list of pressure measuring system 1 Cuff 2 Air pipe 3 PCBA 4 Pump 5 Valve CUFF AIR HOSE AIR CONNECTOR PLUG LCD DISPLAY DC POWER SOCKET MEM BUTTON START STOP SET BUTTON BATTERY COMPARTMENT 5 AC Adaptor KH0601000UW Average value The average value of blood pressure Motion indicator Motion may result in an inaccurate measurement Bluetooth icon Da...

Page 6: ...that is stored in the memory The setting range of the year 2016 2056 Time format 24H When the monitor is off press button it will display the time Then press and hold button to enter the mode for year setting Notes 1 During the process of setting you can press button to stop setting at any time 2 If there is no operation during the process of setting it will turn off within 1 minute Press button t...

Page 7: ... UNIT Repeat steps 2 and 3 to set the HOUR and MINUTE 5 When you get the right year press button to set down and turn to next step After the unit is set the LCD will display done first then display all the settings you have done and then turn off 11 10 BEFORE YOU START BEFORE YOU START ...

Page 8: ...h are ON when pair up is proceeding If this is the first time you use MedM Health please register an account first Enter your account and password to log in Please enter My Profile to set your pernal information Please enter Settings infterface click My Devices select Add the Device When the monitor is OFF press and hold the button to start pair up The symbol and will display alternatively indicat...

Page 9: ...up process is complete Bluetooth Module No AW51822 RF Frequency Range 2402 MHz to 2480 MHz Output Power Range 4 dBm Supply Voltage 1 8V 3 6 V Transmitting Distance 10 meters CAUTION 1 2 List of compatible devices For iOS devices The operating system must be iOS 8 or more such as iPhone 4S iPhone 5 5C 5S iPhone 6 6 Plus and so on For Android devices The operating system must be 4 3 or more Interfer...

Page 10: ...easurement range SYS 60mmHg to 230mmHg or DIA 40mmHg to 130mmHg or Pulse 40 199 pulse minute the LCD will display out 3 With TMB 1597 BN successfully pair up with your mobile device the measurement data will be automatically transmitted to your mobile device via Bluetooth 1 The symbol will disappear after successful data transmission and you may check your personal health data stored in your mobil...

Page 11: ... the average value of the latest three records Take user 1 for example Press button or button to get the records you want The record number date and time of the measurement records will display alternately If you want to check another user s records press button to turn off the monitor when the blood pressure monitor is in the memory inquiry mode Press and hold button to enter into the selecting u...

Page 12: ...n delete all results for the selected user by following steps Take User 1 for example Hold pressing button about 3 seconds when the monitor is in the memory recall mode the flash display dEL ALL User ID will show 1 Press button to confirm deleting and the monitor will display User ID dEL dOnE and then turn off 2 Note To exit out of delete mode without deleting any records press button before press...

Page 13: ...nt Do not attempt to clean the reusable cuff with water and never immerse the cuff in water An irregular heartbeat IHB is detected when a heartbeat rhythm varies while the unit is measuring the systolic and diastolic blood pressure During each measurement the monitor records the heartbeat intervals and calculates the average If any average is larger than or equal to 25 the irregular heartbeat symb...

Page 14: ...s you think it should check here before arranging for servicing PROBLEM SYMPTOM CHECK THIS REMEDY No power Low batteries Error message Display will not light up Batteries are exhausted Replace with new batteries Insert the batteries correctly Replace with new batteries Batteries are inserted incorrectly Display is dim or show Batteries are low E 01 shows E 03 shows E 04 shows EExx shows on the dis...

Page 15: ...rvice usual problems and customer download transtek will serve you anytime Manufactured by Company Address Authorized Component 1 please use the TRANSTEK authorized adapter Guangdong Transtek Medical Electronics Co Ltd Zone B No 105 Dongli Road Torch Development District Zhongshan 528437 Guangdong China Guangdong Transtek Medical Electronics Co Ltd Rated cuff pressure 0mmHg 300mmHg 0kPa 40kPa Meas...

Page 16: ...in conjunction with any other antenna or transmitter FCC ID OU9TMB1597BN ISO 14971 2007 Medical devices Application of risk management to medical devices EN 1041 2008 Information supplied by the manufacturer of medical devices IEC 60601 1 2 2014 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance Collateral standard Electromagnetic compatibility Re...

Page 17: ...ion electromagnetic immunity IMMUNITY test 6 kV contact 8 kV air 6 kV contact 8 kV air 2 kV for power supply lines 1 kV line s to line s 2 kV line s to earth 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec 3A m NOTE UT is the a c mains voltage prior to application of the test level Table 2 Guidance and MANUFACTURER s decl...

Page 18: ...ed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above the device should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the device Over the frequency range 150 ...

Reviews: