background image

User Manual

Blood Pressure Monitor

TMB-1591-BS

To use the monitor correctly and safely, please read the manual 

thoroughly.

Thank you very much for selecting TRANSTEK Blood Pressure 

Monitor TMB-1591-BS.

Please keep this manual well in order to reference in future.

Arm Type

version:1.0

Guangdong Transtek Medical Electronics Co., Ltd.

Zone A, No.105 ,Dongli Road, Torch Development District, 

528437 Zhongshan,Guangdong,China  

FCC ID:OU9TMB1591B2

Summary of Contents for TMB-1591-BS

Page 1: ...ghly Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB 1591 BS Please keep this manual well in order to reference in future Arm Type version 1 0 Guangdong Transtek Medical Electron...

Page 2: ...MATION FOR USER 14 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 16 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Irregular heartbeat de...

Page 3: ...l booklet To signify that the instruction manual booklet must be read Symbol for Manufacturer Symbol for Serial Number Symbol for Type BF applied part Symbol for Direct Current The symbol indicates th...

Page 4: ...h frequency HF surgical equipment at the same time CAUTION Warning This device is not AP APG equipment Do not use the device where flammable anesthetic are present or in environments mixture with air...

Page 5: ...nt The grade of the blood pressure Component list of pressure measuring system 1 Cuff 2 Air pipe 3 PCBA 4 Pump 5 Valve Monitor Components BATTERY COMPARTMENT ON STANDBY BUTTON LCD DISPLAY AIR HOSE AIR...

Page 6: ...e old batteries are harmful to the environment do not dispose with other daily trash Remove the old batteries from the device and follow your local recycling guidelines CAUTION Replace the batteries w...

Page 7: ...cuff should be snug but not too tight You should be able to insert one finger between the cuff and your arm 3 Sit comfortably with your arm resting on a flat surface 2 3cm 4 Correct position Bare you...

Page 8: ...by button another reading is initiated If the user presses and holds the On Standby button for 2 seconds the device powers down Or if there is no operation after a 10 seconds of inactivity the device...

Page 9: ...urine Measurements may be inaccurate if taken in the following circumstances Maintenance In order to get the best performance please follow the instructions below Put in a dry place and avoid the suns...

Page 10: ...the IHB icon indicates that a pulse irregularity consistent with an irregular heartbeat was detected during measurement Usually this is NOT a cause for concern However if the symbol appears often we r...

Page 11: ...DIA 40mmHg 130mmHg 5 3kPa 17 3kPa Pulse value 40 199 beat minute Pressure 5 40 within 3mmHg pulse value 5 Temperature 20 C to 60 C A relative humidity range of 93 non condensing at a water vapour pre...

Page 12: ...with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation...

Page 13: ...ecessary instructions for maintaining BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to electromagnetic disturbances for the excepted service life 2 Guidance and manufacturer s declaration electro...

Page 14: ...IMMUNITY to RF wireless communicati ons equipment Band MHz Distance m IEC 60601 1 2 Test Level V m TETRA 400 Pulse modulation 18 Hz GMRS 460 FRS 460 FM 5k Hz deviation 1 kHz sine LTE Band 13 17 Pulse...

Reviews: