background image

38

39

EMC GUIDANCE

EMC GUIDANCE

 

Guidance and manufacturer’s declaration – electromagnetic Immunity 

Immunity Test

 

±8 kV contact
±2 kV, ±4kV, ±8 kV,  ±15 kV air 

±8 kV contact

 

Table 2 

Compliance level

Electrostatic 
discharge 

(ESD)

 

IEC 61000-4-2 

Voltage dips, short 

interruptions and 

voltage variations 

on power supply

 input lines 

IEC 61000-4-11

Electrical fast 
transient/burst 
IEC 61000-4-4 
Surge
IEC61000-4-5

IEC 60601-1-2 

Test level

±2 kV, ±4kV, ±8 kV,  

±15 kV air 

Not application

Not application

Not application

Not application

Not application

Not application

 

30 A/m

50Hz/60Hz

NOTE      U

is the a.c. mains voltage prior to application of the test level. 

30 A/m

50Hz/60Hz

 Power frequency 

magnetic field

IEC 61000-4-8

Conduced RF

IEC61000-4-6

10 V/m

80 MHz – 2,7 GHz

80 % AM at 1 kHz

10 V/m

80 MHz – 2,7 GHz

80 % AM at 1 kHz

Radiated RF

IEC61000-4-3

Not application

Not application

Summary of Contents for Medel Soft TMB-1581-S

Page 1: ...Co Ltd Zone A No 105 Dongli Road Torch Development District Zhongshan 528437 Guangdong China To use the monitor correctly and safely please read the manual thoroughly Thank you very much for selectin...

Page 2: ...tenance ABOUT BLOOD PRESSURE 26 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Irregular heartbeat detector Why does my blood pressure fluctuate t...

Page 3: ...rement pulse rate measurement and the result storage The design provides you with two years of reliable service Readings taken by the TMB 1581 S are equivalent to those obtained by a trained observer...

Page 4: ...d for patient transport outside a healthcare facility The device is not intended for public use This device is intended for no invasive measuring and monitoring of arterial blood pressure It is not in...

Page 5: ...ore and after use Don t use any abrasive or volatile cleaners The device doesn t need to be calibrated within two years of reliable service Warning Do not apply the cuff over a wound otherwise it can...

Page 6: ...s and their base stations walkie talkies can affect this equipment and should be kept at least a distance d away from the equipment The distance d is calculated by the MANUFACTURER from the 80 MHz to...

Page 7: ...ar Hour Minute Heartbeat Blood pressure monitor is detecting an irregular heartbeat during measurement Blood pressure level indicator Indicate the blood pressure level Blood pressure monitor is detect...

Page 8: ...A 2 Air Pipe 3 Pump 4 Valve 5 Cuff List 1 Wrist Blood Pressure Monitor TMB 1581 S 2 2 AAA batteries 3 User manual Slide off the battery cover Install the batteries by matching the correct polarity as...

Page 9: ...mful to the environment Do not dispose with daily garbage Remove the old batteries from the device following your local recycling guidelines Setting Date Time and Measurement Unit It is important to s...

Page 10: ...lection and it will turn to the next step 4 Repeat step 2 and 3 to confirm MONTH and DAY 5 6 Repeat step 2 and 3 to confirm HOUR and MINUTE Repeat step 2 and 3 to confirm the MEASUREMENT UNIT After co...

Page 11: ...measurement please sit comfortably with legs uncrossed feet flat on the floor back and wrist supported Rest for 5 minutes before measuring Wait at least 3 minutes between measurements This allows you...

Page 12: ...it will display the next record and so on During the process of displaying the results if there is no operation the blood pressure monitor will turn off in one minute Or you can press START STOP butt...

Page 13: ...the right display will be shown Note To exit out of delete mode without deleting any records press START STOP button before pressing MEM to confirm any delete commands 1 2 Press MEM to confirm deletin...

Page 14: ...a very cold environment When you want to discharge urine Maintenance To obtain the best performance please follow the instructions below INFORMATION FOR USER INFORMATION FOR USER TROUBLESHOOTING Avoi...

Page 15: ...n the heart relaxes between heartbeats the lowest blood pressure is diastolic pressure Irregular Heartbeat Detector CAUTION The appearance of the IHB icon indicates that a pulse irregularity consisten...

Page 16: ...s but there will be some different results for different people We suggest you measure the same wrist every time The cuff is not secure Refasten the cuff and then measure again This section includes a...

Page 17: ...0 C within 3mmHg 0 4kPa Pulse value 5 Rated cuff pressure 0mmHg 299mmHg 0kPa 39 9kPa Measurement pressure SYS 60mmHg 230mmHg 8 0kPa 30 7kPa DIA 40mmHg 130mmHg 5 3kPa 17 3kPa Pulse value 40 199 beat mi...

Page 18: ...ectronics Co Ltd SPECIFICATIONS CONTACT INFORMATION A01 Internally Powered ME Equipment IP22 The first number 2 Protected against solid foreign objects of 12 5mm and greater The second number Protecte...

Page 19: ...labelling and information to be supplied Part 1 General requirements EN 1060 3 1997 A2 2009 Non invasive sphygmomanometers Part 3 Supplementary requirements for electro mechanical blood pressure measu...

Page 20: ...eased electromagnetic immunity of this equipment and result in improper operation Warning Portable RF communications equipment including peripherals such as antenna cables and external antennas should...

Page 21: ...4 11 Electrical fast transient burst IEC 61000 4 4 Surge IEC61000 4 5 IEC 60601 1 2 Test level 2 kV 4kV 8 kV 15 kV air Not application Not application Not application Not application Not application N...

Page 22: ...odulation b 18Hz 1 8 450 430 470 GMRS 460 FRS 460 FM c 5kHz deviation 1kHz sine 2 0 3 28 710 704 787 745 780 LTE Band 13 17 Pulse modulation b 217Hz 0 2 0 3 9 810 870 930 800 960 GSM 800 900 TETRA 800...

Reviews: