When carrying out usual maintenance, please ensure practice of the following Do’s and
Don’ts:
Transtek warrants its products free of defects in materials and workmanship in normal
use for a period of TWO years from the date of retail purchase.
This warranty does NOT cover damages caused by misuse or abuse, including but not
limited to:
Failure caused by unauthorized repairs or modifications;
Damage caused by shock or drop during transportation;
Failure caused by improper operation inconsistent with the instructions stated in this user
manual;
Malfunction or damage from failure to provide the recommended maintenance;
Damage caused by improper use of power supply.
Should this device require maintenance (or replacement at our option) under warranty,
please deliver the original package to GUANGDONG TRANSTEK MEDICAL
ELECTRONICS CO., LTD prepaid. Please return the store receipt (with the retail
purchase date) and a note with reasons to return on it as well.
Specifications
Maintenance
Warranty
Product Name
Dimension
Body Fat Analyzer (GBF-1319-B)
Scale: 300x300x23mm
Panel: 300x300x6mm
Net Weight
Approximately 1.85 kg
Display
Digital LCD
V.A.: 76x51mm
Measurement Unit
Kilogram / Stone/ Pound
Measurement Range
5kg to 180kg / 0st: 11lb to 28st: 5lb / 11lb to 397lb
Division
0.1kg / 0.2lb
Accuracy
5-50kg: ±0.3kg;
100-150kg: ±0.5kg;
Working Environment
Temperature: 10
℃
to 40
℃
Humidity: ≤90% RH
Storage Environment
Temperature: -20
℃
to 55
℃
Power Source
4.5V (3xAAA Batteries)
Turn on Method
SENSE ON technology
Auto-OFF
The scale will turn off after about 10s if there is no operation.
Accessories
1. 3xAAA batteries
2. User Manual
About the Accuracy of This Product
This product passes strict inspection before delivery and therefore its accuracy is guaranteed by the manufacturer.
Please refer to the above table for the descriptions on accuracy.
This product is specially designed for body fat analysis as well as weight measurement. It should NOT be used by
anyone during the process of transaction for verification of goods’ weight.
GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD
Zone A, 5/F., Investment Building, No. 12 Huizhan East Rd., Torch Development District,
Zhongshan, 528437, Guangdong, China
Tel: 86-760-88282982
Website: http://www.transtek.cn
22
50-100kg: ±0.4kg;
150-180kg: ±0.7kg
Humidity: 15%RH to 90% RH
Mode of Operation
Continuous Operation
Protection Against
Ingress of Water
IPX0
Software Version
1.0
Specifications
DO use a dry soft cloth to wipe the dust.
DO use a wet soft cloth, dipped into water and wrung out, to wipe the dirt. Then use a
dry soft cloth to dry up the device.
DON’T wash the device with water or immerse it in water.
DON’T use propellant, abrasive or other chemicals to wipe the dirt in avoidance of
discolor or malfunction.
DON’T disassemble this device. If you have any problems, please contact Transtek.
(
Please refer to Warranty for contact information
)
Maintenance
23