background image

7

6

Transtek Body Fat Analyzer BF-1256-B1 applies BIA (Bio-impedance Analysis) 

technology. A small amount of weak current flows through the human body so as to detect 

the bio-impedance and estimate body fat, body water, muscle mass and bone mass. The 

electrical current is small and may not be felt. 

This BIA technology is cheap, safe, non-invasive, toxic-free and harmless. It also 

possesses the characteristics of simple operation and abundant information. 

The current mentioned above is less than 0.5mA. However, please be aware that anyone 

with an wearable or implantable medical electronic instrument, such as a pacemaker, must 

avoid using this device.

The intended use of this device is for healthy children 10-17 years old and healthy adults. 

General Instructions

If SUCCEED, symbol         will be shown on the LCD.

If FAIL, symbol “E1” will be shown on the LCD.

Initial Start-Up

Initial Start-Up

Pair-Up

With the advanced Bluetooth 4.0 technology applied, the mobile or portable equipments, 

which are equipped with Bluetooth function in line with BLE Technical Specifications 

established by global organization Bluetooth SIG, are capable to receive your personal 

health data.

Turn on Bluetooth and the App. Make sure both are ON when pair-up is proceeding.

Press and hold “UNIT” button in the back of the scale to start pair-up. 

Symbol         and symbol         will be shown on the 

LCD alternatively, indicating pair-up is proceeding.

CAUTION

When the symbol         appears, the device will power off. Then you shall replace with a new set of 

batteries. Please replace all four batteries at the same time. Do NOT mix the old batteries with the new 

one. 

Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage. 

Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries 

and scrapped device.

If you do not intend to use this unit for a prolonged period of time, it is advisable to remove the batteries

before storing.

Insert the Batteries

Open the battery door in the back of the scale.

Insert the batteries (4 x 1.5V AAA) into the battery 

compartment according to the polarity indications 

marked inside the compartment.

* The digits “          ” will be shown on the LCD.

Close the battery door and wait until the digits “    ” 

are shown on the LCD.

Battery Life: Approx. 120 days

(Battery capacity: 230 mAH. If measured three times per day, each measurement takes about 46s. 

The current for measurement is about 30 mA , while the current when shutdown is about 30 uA.)

Power Supply

Battery Mode: 6V, 4 x AAA batteries

Summary of Contents for BF-1256-B1

Page 1: ...7 China TEL 86 760 88282982 www transtek cn User Manual Body Fat Analyzer BF 1256 B1 Please do read the user manual carefully and thoroughly so as to ensure the safe usage of this product and keep the manual well for further reference in case you have problems Thank you very much for selecting the Transtek Body Fat Analyzer BF 1256 B1 Contains FCC ID OU9AW8001 LS ...

Page 2: ...le Weight Only Operation Start Measuring First Measurement Daily Measurement Manage Your Health Body Fat Indicator Data Transmission Troubleshooting Error Prompt When Measuring When Data Transmitting Specifications Maintenance Warranty FCC Regulations Appendix Table of Body Fat Level Table of Body Water Level Muscle Mass Percentage Bone Mass Percentage Health Tips About Body Fat EMC Guidance 2 3 4...

Page 3: ...able on request circuit diagrams component parts list etc WARNING No modifications of this equipment is allowed This may result in increased EMISSIONS or decreased IMMUNITY of BF 1256 B1 Please use the device according to the user manual Any misuse can cause electric shock burns fire and other unexpected hazards Please use and storage the device under the environment which was provided in the user...

Page 4: ...de Battery Compartment UNIT Button Electrode LCD Display Body Fat Analysis Result Total Body Water Analysis Result Muscle Mass Analysis Result Bone Mass Analysis Result Stone Pound Kilogram Percentage Foot Centimeter Age Man Sportsman Woman Sportswoman User ID Successful Bluetooth Connection Data transmitting pending to transmit to wireless wellness system Low Battery ...

Page 5: ...a Turn on Bluetooth and the App Make sure both are ON when pair up is proceeding Press and hold UNIT button in the back of the scale to start pair up Symbol and symbol will be shown on the LCD alternatively indicating pair up is proceeding CAUTION When the symbol appears the device will power off Then you shall replace with a new set of batteries Please replace all four batteries at the same time ...

Page 6: ...function key or to increase or decrease the numeral Range 100 cm to 220 cm 3 3 5 7 2 5 ft You may press and hold the function key or for fast changing the numeral Press SET key to confirm Stature After confirming User ID the system will divert to Gender setting automatically As pictured below the portrait blinks The operator may press the function key or to select Gender Press SET key to confirm G...

Page 7: ...oubleshooting for more details STEP 1 Step on the platform barefooted Weight Only Operation Your TRANSTEK Body Fat Analyzer will operate as a conventional weight reading scale No special programming steps are required Once the scale is initialized as previously described you may simply step on the scale to measure your current weight For only weight reading 1 Position the scale on a flat hard surf...

Page 8: ...stem will automatically identify the possible User ID with most similar history records Then the measuring results will be displayed sequentially three times When the system finds out two or more users with similar history records it will notify you to choose between for example P1 and P2 You may press key for P1 and or key for P2 The measuring results will then be sorted into the User ID you sele...

Page 9: ...eries for replacement The system cannot identify the possible User ID with most similar data Please assign a User ID following the instruction in Set Up Your Profile The user fails to select the User ID from what the system found Please assign a User ID following the instruction in Set Up Your Profile Error Prompt Error Description Solution Overload The device will power off Stop using this scale ...

Page 10: ...ned When Data Transmitting Specifications Product Name Dimension Net Weight Display Measurement Unit Measurement Range Division 0 1kg 0 2lb Accuracy 5 50kg 0 3kg 100 150kg 0 5kg Working Environment Temperature 5 to 40 Storage Environment Temperature 20 to 60 Power Source 6V Four AAA size Batteries Turn on Method SENSE ON technology Auto OFF Accessories 1 Four AAA size batteries 2 User Manual 50 10...

Page 11: ... This device complies with FCC radiation exposure limits set forth for an uncontrolled environment FCC Regulations 19 18 Maintenance When carrying out usual maintenance please ensure practice of the following Do s and Don ts Transtek warrants its products free of defects in materials and workmanship in normal use for a period of FIVE years from the date of retail purchase This warranty does NOT co...

Page 12: ...to 20 21 to 29 30 to 32 33 and over 70 to 63 63 to 57 57 to 55 55 to 37 70 to 58 58 to 52 52 to 49 49 to 37 OPTIMAL TBW RANGE Source Derived from Wang Deurenberg Hydration of fat free body mass American Journal Clin Nutr 1999 69833 841 Bone Mass Percentage Source Rico et al 1993 The average bone mass percentage for both men and women is between 4 to 5 Health Tips About Body Fat EMC Guidance Table ...

Page 13: ...ME EQUIPMENT and ME SYSTEMS that are not LIFE SUPPORTING Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test IEC 60601 TEST LEVEL Compliance level Electromagnetic environment guidance Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 Vrms 150 kHz to 80 MHz 3 V m 80 MHz to 2 5 GHz 3 V m Recommended separation distance P V d 5 3 1 P d 2 333 800 MHz to 2 5 GHz where P ...

Page 14: ... distance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz P V d 5 3 1 80 MHz to 800 MHz 800 MHz to 2 5 GHz 1 0 0 1 0 1 0 1 0 0 1 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the max...

Reviews: