Transmitter Solutions Reign XRE-100 Manual Download Page 11

The warranty period of this product is 24 months, beginning from the manufacturing date.  During this period, if the 
product does not operate correctly, due to a defective component, the product will be repaired or replaced at the sole 
discretion of Transmitter Solutions.  This warranty does not extend to the product casing which can be damaged by 
conditions outside of the control of Transmitter Solutions.

EXCEPT AS SET FORTH ABOVE, TRANSMITTER SOLUTIONS MAKES NO WARRANTIES REGARDING THE GOODS, EXPRESS OR IMPLIED, 
INCLUDING WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.  BUYER MAKES NO RELIANCE ON 
ANY REPRESENTATION OF TRANSMITTER SOLUTIONS, EXPRESS OR IMPLIED, WITH REGARD TO THE GOODS AND ACCEPTS THEM 
“AS-IS/WHERE-IS”. TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION THAT TRANSMITTER SOLUTIONS WILL HAVE NO 
LIABILITY OF ANY KIND AS A RESULT OF THE SALE.  BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY FOR 
DAMAGES OF ANY KIND, WHETHER DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING INJURIES TO PERSONS OR PROPER-
TY, TO BUYER, ITS EMPLOYEES OR AGENTS, AS A RESULT OF THE SALE.  BUYER ALSO AGREES TO HOLD TRANSMITTER SOLUTIONS 
HARMLESS FROM ANY CLAIMS BUYER, OR ANY THIRD PARTY, MAY HAVE AS A RESULT OF BUYER’S USE OR DISPOSAL OF THE GOODS. 
BUYER HAS READ THIS DISCLAIMER AND AGREES WITH ITS TERMS IN CONSIDERATION OF RECEIVING THE GOODS.

WARRANTY

11

Summary of Contents for Reign XRE-100

Page 1: ...2 24 Volts AC DC power and the DRY input closures you want to extend If you would like to survey the range capability before install simply provide power to both units and press the PROG TEST button alternately on each unit Successful transmission and reception will be indicated on the transmit and receive LEDs on each unit as described below v 8 29 18 X R E 1 0 0 RELAY EXTENDER There are two piec...

Page 2: ...2 ...

Page 3: ...Encryption AES 1 POWER DETAILS 4 2 LED INDICATORS 5 3 RELAY DIAGRAM AND WIRING 6 4 ALERT RELAYS 7 5 DIP SWITCHES 8 6 BATTERY BACKUP 9 7 PAIRING IN THE FIELD 9 TROUBLESHOOTING 1 0 POWER INPUT 12 to 24 VOLTS AC DC 1 AMP Minimum Always follow polarity when DC Power is used BATTERY INPUT for 12 Volt Sealed Lead Acid SLA battery only Solid GREEN LED indicates battery charging Momentarily flashing GREEN...

Page 4: ...AST 1AMP POWER SUPPLY POWER INPUT Power Input 12 to 24 VOLTS AC DC Always follow polarity when DC Power is used 1 AMP Minimum BATTERY INPUT Battery Input for 12 Volt Sealed Lead Acid SLA battery only Solid Green LED Battery charging Momentary Flashing LED Battery is fully charged and a trickle conditioning charge is occurring 1 2 2 1 4 ...

Page 5: ... result of an Relay Input change event or handshake STATUS PROG flashes yellow patterns indicating status of the unit pairing error etc RUN flashes ORANGE 1 second ON and 1 second OFF indicating the microprocessor is running POWER LED Glows solid orange when power is present 5 volt relay supply 3 3 volt logic supply and VPA 3 6 volt power amplifier supply 1 3 1 2 3 4 5 4 2 5 5 ...

Page 6: ...XRE 100 A closure on RLY2 COM input will result in a closure on RLY2 NC COM NO output of the paired XRE 100 RELAY OUTPUTS Relay Outputs The Reign XRE 100 comes with 2 relay outputs Each output follows RELAY INPUTS from remote paired XRE 100 When RLY1 or RLY2 INPUTS are closed RLY1 and RLY2 OUTPUTS are energized and connect NC COM NO respectively This relay state is also indicated by the GREEN ACTI...

Page 7: ...d with the supplied 3K ohm resistor Simply insert the resistor into the Rx and COM pins on the desired connector and tighten screw blocks If Supervised Inputs are not desired simply leave DIPSWITCH 2 OFF and wire your contact directly across the Rx and COM pins NOTE Communication Loss If the XRE 100 units stop communicating the Alert Relay Output Black relay will trigger Alerting on loss of commun...

Page 8: ...n XRE 100 to XRE 100 Relay Extension operation PROGRAM TEST BUTTON Program Test Button used with MODE SWITCH 1 to field pair units as described above Functions as a TEST TRANSMIT button during normal operation When pressed the XRE 100 will send a radio test packet and the RED TRANSMIT LED will illuminate If the paired XRE 100 is online it will acknowledge with a radio test packet indicated by a mo...

Page 9: ...1 to ON on both units Press the PROG TEST button on either unit NOTE Observe the STATUS PROG LED flashing Flip Dipswitch 1 to OFF on both units Press PROG TEST and observe TRANSMIT and RECEIVE LEDs operating normally Pairing procedure overwrites any previous units For example if replacing a unit simply follow the above procedure with the existing and replacement unit 7 PAIRING UNIT IN THE FIELD 1 ...

Page 10: ...tary on the green receive LED If you do not see the transmit and receive LED lights activate 1 Power cycle both the XRE units 2 Move the XRE 100 units to a higher location and avoid mounting on in metal objects If you are not getting the desired range between XRE 100 units 1 Ensure that the both devices are powered by their own dedicated power supply 2 Ensure that 1 amp of power draw is available ...

Page 11: ...YER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED WITH REGARD TO THE GOODS AND ACCEPTS THEM AS IS WHERE IS TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF THE SALE BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY FOR DAMAGES OF ANY KIND WHETHER DIRECT INCIDE...

Page 12: ...PH 866 975 0101 FX 866 975 0404 www transmittersolutions com ...