Installation 

Observe ESD Precautions 

Always observe the following ESD (Electrostatic Discharge) precautions when installing or handing the M/GE-T-xxx-01 
media converter: 

 

Do not remove the converter from its protective packaging until you are ready to install it. 

 

Wear an ESD wrist grounding strap before handling any module or component. If you do not have a wrist strap, 
maintain grounded contact with the system unit throughout any procedure requiring ESD protection. 

Copper and Fiber Ports 

The figure below shows the front panel of the M/GE-T-xxx-01 media converters. 

 

Connect the Fiber Cable 

Full duplex (always ON) is on the fiber side only; therefore, the 512-Bit Rule does not apply. The cable lengths are 
constrained by the cable requirement. 

1. Locate or build IEEE 803.2™ compliant 1000Base

-X fiber cable with male, two-stranded TX to RX connectors installed 

at both ends. 
2. Connect the fiber cable to the M/GE-T-xxx-01 media converters as follows: 

 

Connect the male TX cable connector to the female TX port. 

 

Connect the male RX cable connector to the female RX port. 

3. Connect the fiber cable to the other device (another media converter, hub, etc.) as follows: 

 

Connect the male TX cable connector to the female RX port. 

 

Connect the male RX cable connector to the female TX port. 

 

Summary of Contents for M/GE-T Series

Page 1: ...able 3 Connect the Twisted pair Copper Cable 4 Power up the Media Converter 4 Power Adapter 5 Operation 5 Status LEDs 5 Features 6 Cable Specifications 6 Technical Specifications 8 Troubleshooting 9 C...

Page 2: ...e T RJ 45 100m 328 ft to 1000Base LX 1310m single mode SC 10 km 6 2 mi Link Budget 10 5db M GE T SFP 01 1000Base T RJ 45 100m 328 ft to SFP slot empty Typical maximum cable distance actual distance de...

Page 3: ...Ports The figure below shows the front panel of the M GE T xxx 01 media converters Connect the Fiber Cable Full duplex always ON is on the fiber side only therefore the 512 Bit Rule does not apply The...

Page 4: ...erter 3 Connect the RJ 45 connector at the other end of the cable to the RJ 45 port on the other device switch workstation etc Note With Fiber Link Pass Through permanently enabled the copper Link LED...

Page 5: ...nverter is powered up by observing that the front panel LED power PWR indicator is lit DC Power Consult the user guide for the Transition Networks SPS 2460 SA DC external power supply for powering the...

Page 6: ...of a loss of link Link Pass Through provides the media converter with the ability to monitor both the fiber and the copper RX ports for a loss of signal If a loss of RX signal occurs on one media por...

Page 7: ...Cable Distance 100 meters Straight through or crossover twisted pair cable may be used Shielded STP or unshielded UTP twisted pair cable may be used Pins 1 2 and 3 6 are the two active pairs in an Et...

Page 8: ...bundled with typical Greater than 41 660 MIL HDBK 217F Hours 50 000 hour power supply Greater than 114 580 Bellcore Hours Warranty Lifetime For current information on the M GE T xxx 01 view the online...

Page 9: ...ep 2 Note the following As a link pass through device both copper and fiber cables must be installed before the LEDs will light 2 Are the FX Link and TX Link Act LEDs lit on the RJ 45 port NO Check th...

Page 10: ...hich case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital app...

Page 11: ...o observe this caution could result in damage to the public telephone network Der Anschluss dieses Ger tes an ein ffentlickes Telekommunikationsnetz in den EGMitgliedstaaten verst sst gegen die jeweli...

Reviews: