Transition Networks SSDTF3011-110 User Manual Download Page 4

INSTALLATION

(continued)

Install Cable

(continued)

COPPER

E1 75 OHM (COAX CONNECTOR)

NOTE: Ground coax segment to earth ground at one end.

Locate or build coax cables  that are compliant with
specifications on page 10.

Connect BNC connector at one end of cable to media
converter.

Connect BNC connector at other end of cable to network
equipment..

Power the Media Converter 

1.

Install power adapter cord at back of media converter.

2.

Connect power adapter plug to AC power.

3.

Verify that media converter is powered by observing illuminated
LED(s).

OPERATION 

Status LEDs

Use the status LEDs to monitor media converter
operation in the network. 

SDC

Signal Detect/Copper

- Steady LED

indicates twisted-pair copper link is up.

Flashing LED (once/second) indicates transmitting All Ones
(AIS) on link if 

fiber

link (switch selectable) is down.

Flashing LED (5 times/second) indicates All Ones detected on
Link.

SDF

Signal Detect/Fiber

- Steady LED indicates fiber link is up.

Flashing LED (once/second) indicates transmitting All Ones
(AIS) on link if 

copper

link (switch selectable) is down.

Flashing LED (5 times/second) indicates All Ones detected on
Link.

P(o)W(e)R

Steady green LED indicates connection to external AC power.

FAULT ISOLATION and CORRECTION

If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:

1.

Is the P(o)W(e)R LED on the media converter illuminated?
NO

Is the power adapter the proper voltage and cycle frequency for the
AC outlet? 
NOTE: Refer to the “Power Supply Requirements” on page 7. 

Is the power adapter properly installed in the media converter and
in the outlet?

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 2.

2.

Is the SDF (Signal Detect/Fiber) LED illuminated?
NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other media converter.

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 3.

3.

Is the SDC (Signal Detect/Copper) LED illuminated?
NO

Check coax cables for proper connection.

Check integrity of device attached to media converter by coax
cable.

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

SSDTF30xx

5

PWR

SDF

SDC