CABLE SPECIFICATIONS
Fiber Cable
Bit error rate:
1 0
-9
MULTIMODE
Fiber Optic Cable Recommended:
62.5 / 125 µm multimode fiber
Optional:
100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
SSDTF3011
850 nM
Fiber Optic Transmitter Power:
min: -14.0 dBm
max: -12.0 dBm
Fiber Optic Receiver Sensitivity:
min: -25.0 dBm
max: -12.0 dBm
Typical
Maximum Cable Distance*:
2 kilometers
SSDTF3013
850 nM
Fiber-optic Transmitter Power:
min: -14.0 dBm
max: -12.0 dBm
Fiber-optic Receiver Sensitivity:
min: -25.0 dBm
max: -12.0 dBm
Typical
Maximum Cable Distance*:
2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended:
9 µm singlemode fiber
SSDTF3012
1300 nM
Fiber-optic Transmitter Power:
min: -21.0 dBm
max: -14.0 dBm
Fiber-optic Receiver Sensitivity:
min: -25.0 dBm
max: -14.0 dBm
Typical
Maximum Cable Distance*:
8 kilometers
SSDTF3014-110
1300 nM
Fiber-optic Transmitter Power:
min: -21.0 dBm
max: -14.0 dBm
Fiber-optic Receiver Sensitivity:
min: -27.0 dBm
max: -14.0 dBm
Typical
Maximum Cable Distance*:
8 kilometers
SSDTF3015-110
(long haul)
1300 nM
Fiber-optic Transmitter Power:
min: -15.0 dBm
max: -5.0 dBm
Fiber-optic Receiver Sensitivity:
min: -27.0 dBm
max: -14.0 dBm
Typical
Maximum Cable Distance*:
15 kilometers
SSDTF3022
(long haul)
1300 nM
Fiber-optic Transmitter Power:
min: -15.0 dBm
max: -5.0 dBm
Fiber-optic Receiver Sensitivity:
min: -25.0 dBm
max: -14.0 dBm
Typical
Maximum Cable Distance*:
15 kilometers
*Actual distance dependent upon physical characteristics of network installation.
Coax Copper Cable
E1:
Cable Type
RG-58
Gauge
24 to 22 AWG
Attenuation
2 dB/100 meters @ 1.0 MHz
Differential Characteristic Impedance
75 ±10%
Set 4-Position Switch
NOTE: E1 must be selected (
LEFT SWITCH SET
#4 DOWN) for proper operation.
Install Cable
FIBER
1.
Locate or build fiber cables that are compliant with specifications
on page 9, with male two-stranded TX to RX connectors installed at
both ends.
2.
Connect cable with connector installed at TX location on media
converter to RX location on attached device.
3.
Connect cable with connector installed at RX location on media
converter to TX location on attached device.
SSDTF30xx
3
6
NETWORK Switch Settings
Switch #4 DOWN
1 2 3 4
1
2
1
2
1
2
1
2
Transmit All Ones onto Fiber
on Loss of Copper Carrier Detect
UP = Enabled
E1 Selection
DOWN = E1
NOT USED
Transmit All Ones onto Copper
on Loss of Fiber Carrier Detect
UP = Enabled
KEY
= UP
= DOWN
1 2 3 4