Transition Networks SSDTF3011-110 User Manual Download Page 3

CABLE SPECIFICATIONS

Fiber Cable 

Bit error rate:

1 0

-9

MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

SSDTF3011

850 nM

Fiber Optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber Optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Typical

Maximum Cable Distance*:

2 kilometers

SSDTF3013

850 nM

Fiber-optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Typical

Maximum Cable Distance*:

2 kilometers

SINGLEMODE

Fiber Optic Cable Recommended:

9 µm singlemode fiber

SSDTF3012

1300 nM

Fiber-optic Transmitter Power:

min: -21.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

Typical

Maximum Cable Distance*:

8 kilometers

SSDTF3014-110

1300 nM

Fiber-optic Transmitter Power:

min: -21.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -27.0 dBm

max: -14.0 dBm

Typical

Maximum Cable Distance*:

8 kilometers

SSDTF3015-110

(long haul)

1300 nM

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -5.0 dBm

Fiber-optic Receiver Sensitivity:

min: -27.0 dBm

max: -14.0 dBm

Typical

Maximum Cable Distance*:

15 kilometers

SSDTF3022

(long haul)

1300 nM

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -5.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

Typical

Maximum Cable Distance*:

15 kilometers

*Actual distance dependent upon physical characteristics of network installation.

Coax Copper Cable 

E1:

Cable Type

RG-58

Gauge

24 to 22 AWG

Attenuation 

2 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance 

75   ±10%

Set 4-Position Switch

NOTE: E1 must be selected (

LEFT SWITCH SET

#4 DOWN) for proper operation.

Install Cable

FIBER

1.

Locate or build fiber cables that are compliant with specifications
on page 9, with male two-stranded TX to RX connectors installed at
both ends.

2.

Connect cable with connector installed at TX location on media
converter to RX location on attached device.

3.

Connect cable with connector installed at RX location on media
converter to TX location on attached device.

SSDTF30xx

6

NETWORK Switch Settings

Switch #4 DOWN

1  2  3  4

1

2

1

2

1

2

1

2

Transmit All Ones onto Fiber

on Loss of Copper Carrier Detect

UP = Enabled

E1 Selection

DOWN = E1

NOT USED

Transmit All Ones onto Copper

on Loss of Fiber Carrier Detect

UP = Enabled

KEY

=  UP

=  DOWN

1     2     3     4 

Reviews: