background image

Transition Networks 

 

SISGM1040-162D-LR 

Technical Support: 1-800-260-1312   

           

International: 00-1-952-941-7600 

Mounting Installation 

 

 

DIN-Rail Mounting 

 

The  DIN-Rail  is  installed  on  the  industrial  switch  at  the  factory.  If  the  DIN-Rail  is  not 

installed, please see the following pictures to screw the DIN-Rail onto the switch. Follow 

the steps below to hang the industrial switch. 

 

 

 

 

 

Summary of Contents for SISGM1040-162D

Page 1: ...6 10 100 1000T 2 10 100 1000T 100 1000 SFP Combo w X Ring Managed Industrial Switch User Manual SISGM1040 162D V1 01 September 2009...

Page 2: ...ts of this manual are based on the table below listing firmware version software kernel version and hardware version If the switch functions are different from the description of the manual please con...

Page 3: ...ver there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tu...

Page 4: ...5 LED Indicators 5 Wiring the Power Inputs 7 Wiring the Fault Alarm Contact 8 Mounting Installation 9 DIN Rail Mounting 9 Wall Mount Plate Mounting 11 Hardware Installation 12 Installation Steps 12 Ne...

Page 5: ...ommands Set 33 Mac Filter Table Commands Set 34 SNMP Commands Set 34 Port Mirroring Commands Set 37 802 1x Commands Set 38 TFTP Commands Set 40 SystemLog SMTP and Event Commands Set 41 SNTP Commands S...

Page 6: ...ystem Event Log Event Configuration 59 Fault Relay Alarm 61 SNTP Configuration 62 IP Security 65 User Authentication 67 Port Statistics 68 Port Control 69 Port Trunk 70 Aggregator setting 70 Aggregato...

Page 7: ...Configuration 94 IGMP Configuration 95 X Ring 97 LLDP Configuration 99 Security 100 802 1X Radius Configuration 100 MAC Address Table 104 Factory Default 109 Save Configuration 110 System Reboot 111...

Page 8: ...rk elasticity and performance It also provides the X Ring function that can prevent network connection failure Benefits System Interface Performance RJ 45 ports support auto MDI MDI X function SFP Min...

Page 9: ...pplication Case Installation IP 30 Protection DIN Rail and Wall Mount Design Spanning Tree Support IEEE 802 1d Spanning Tree Support IEEE 802 1w Rapid Spanning Tree X ring X ring Dual Homing and Coupl...

Page 10: ...em against the checklist 6 10 100 1000T 2 10 100 1000T 100 1000 SFP Combo w X Ring Managed Switch User manual RS 232 RJ 45 cable Pluggable Terminal Block 2 wall mount plates and 6 screws One DIN Rail...

Page 11: ...itch s hardware spec port cabling information and wiring installation Physical Dimension 6 10 100 1000T 2 10 100 1000T 100 1000 SFP Combo w X Ring Managed Switch dimension W x D x H is 72mm x 105mm x...

Page 12: ...LED Indicators There are diagnostic LED indicators located on the front panel of the industrial switch They provide real time information of system and optional status The following table provides de...

Page 13: ...ault Relay Alarm configuration Fault Off Power input 1 and 2 are both active or no power inputs Green SFP port is linking Blinking Data is transmitting or receiving LNK ACT for P7 P8 SFP Off Not conne...

Page 14: ...ernational 00 1 952 941 7600 7 Wiring the Power Inputs Please follow the steps below to insert the power wire Insert the positive and negative wires into the V and V contacts on the terminal block con...

Page 15: ...inal block connector as the picture shows below The switch will provide local indication of a power or port failure if configured by opening the relay contacts The following illustration shows an appl...

Page 16: ...00 1 952 941 7600 9 Mounting Installation DIN Rail Mounting The DIN Rail is installed on the industrial switch at the factory If the DIN Rail is not installed please see the following pictures to scr...

Page 17: ...1312 International 00 1 952 941 7600 10 1 First insert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track 3 Check if the DIN Rail is tightened on the track or not 4 To...

Page 18: ...ail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the ind...

Page 19: ...to the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for information about how to wire the power The power LED on the Industrial sw...

Page 20: ...040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 13 Network Application This section provides some sample applications to guide users A sample application of the industrial...

Page 21: ...dustrial switch supports the X Ring protocol that can help the network recover from a connection failure within 300ms or less ensuring network reliability The X Ring algorithm is similar to Spanning T...

Page 22: ...52 941 7600 15 Coupling Ring Application In the network there may be more than one X Ring group The coupling ring function can connect each X Ring for redundant backup It can ensure transmissions betw...

Page 23: ...ng between an X Ring group and an upper level core switch Assign two ports to be the Dual Homing port that is the backup port in an X Ring group The Dual Homing function works only when the X Ring fun...

Page 24: ...end and an RJ 45 connector on the other Attach the end with the RS 232 connector to a PC or terminal and the other end with the RJ 45 connector to the console port of the switch The connected termina...

Page 25: ...rs to match the following default characteristics of the console port Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters After finishing t...

Page 26: ...2 941 7600 19 Console login interface CLI Management The system supports a command line interface management CLI After you have logged in the system by typing in user name and password you will see a...

Page 27: ...basic tests Displays system information Privileged EXEC Enter the enable command while in user EXEC mode switch Enter disable to exit The privileged command is advance mode Privileged this mode to Di...

Page 28: ...rameters for the switch and Ethernet ports User EXEC E Privileged EXEC P Global configuration G VLAN database V Interface configuration I Commands Set List System Commands Set Command Level Descriptio...

Page 29: ...w IP information of switch switch show ip no ip dhcp G Disable DHCP client function of switch switch config no ip dhcp reload G Halt and perform a cold restart switch config reload default G Restore t...

Page 30: ...hernet 2 switch config dhcpserver ipbinding 192 168 1 1 show dhcpserver configuration P Show configuration of DHCP server switch show dhcpserver configuration show dhcpserver clients P Show client ent...

Page 31: ...switch config interface fastEthernet 2 duplex full half I Use the duplex configuration command to specify the duplex mode of operation for Fast Ethernet switch config interface fastEthernet 2 switch c...

Page 32: ...cast flooded unicast bandwidth type broadcast multicast I Set interface ingress limit frame type to accept broadcast and multicast frame switch config interface fastEthernet 2 switch config if bandwid...

Page 33: ...and to disable the port switch config interface fastEthernet 2 switch config if state Disable show interface configuration I show interface configuration status switch config interface fastEthernet 2...

Page 34: ...P active GroupID 1 4 Port list Member port list This parameter could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less t...

Page 35: ...cription Example vlan database P Enter VLAN configure mode switch vlan database Vlanmode portbase 802 1q gvrp V To set switch VLAN mode switch vlan vlanmode portbase or switch vlan vlanmode 802 1q or...

Page 36: ...3 6 99 or switch vlan vlan 8021q port 3 trunk link tag 3 20 vlan 8021q port PortNumber hybrid link untag UntaggedVID tag TaggedVID List V Assign a hybrid link for VLAN by port if the port belong to a...

Page 37: ...Example spanning tree enable G Enable spanning tree switch config spanning tree enable spanning tree priority 0 61440 G Configure spanning tree priority parameter switch config spanning tree priority...

Page 38: ...global configuration command to set the forwarding time for the specified spanning tree instances The forwarding time determines how long each of the listening and learning states last before the por...

Page 39: ...onfig interface fastEthernet 2 switch config if stp admin p2p Auto stp admin edge True False I Admin Edge of STP priority on this interface switch config interface fastEthernet 2 switch config if stp...

Page 40: ...gh G Configure TOS Priority switch config qos priority tos 3 high show qos P Displays the information of QoS configuration Switch show qos no qos G Disable QoS function switch config no qos IGMP Comma...

Page 41: ...able P Show all MAC address table switch show mac address table show mac address table static P Show static MAC address table switch show mac address table static show mac address table filter P Show...

Page 42: ...s public right rw snmp server host IP address community Community string trap version v1 v2c G Configure SNMP server host information and community string switch config snmp server host 192 168 1 50 c...

Page 43: ...MP configuration switch show snmp no snmp community strings Community G Remove the specified community switch config no snmp community strings public no snmp server host Host address G Remove the SNMP...

Page 44: ...Command Level Description Example monitor rx G Set RX destination port of monitor function switch config monitor rx monitor tx G Set TX destination port of monitor function switch config monitor tx sh...

Page 45: ...usip 192 168 1 1 8021x system serverport port ID G Use the 802 1x system server port global configuration command to change the radius server port switch config 8021x system serverport 1812 8021x syst...

Page 46: ...8021x misc supptimeout sec G Use the 802 1x misc supp timeout global configuration command to set the supplicant timeout switch config 8021x misc supptimeout 20 8021x misc servertimeout sec G Use the...

Page 47: ...how 8021x no 8021x G Disable 802 1x function switch config no 8021x TFTP Commands Set Command Level Description Defaults Example backup flash backup_cfg G Save configuration to TFTP and need to specif...

Page 48: ...nfig smtp enable smtp serverip IP address G Configure SMTP server IP switch config smtp serverip 192 168 1 5 smtp authentication G Enable SMTP authentication switch config smtp authentication smtp acc...

Page 49: ...ow event selection switch show event no event device cold start G Disable cold start event type switch config no event device cold start no event authentication failure G Disable Authentication failur...

Page 50: ...er format yyyymmdd hh mm switch config sntp daylight period 20060101 01 01 20060202 01 01 sntp daylight offset Minute G Set offset of daylight saving time if SNTP function is inactive this command can...

Page 51: ...itch config ring dualhoming ring ringport 1st Ring Port 2nd Ring Port G Configure 1st 2nd Ring Port switch config ring ringport 7 8 ring couplingport Coupling Port G Configure Coupling Port switch con...

Page 52: ...ser such as Microsoft Internet Explorer The Web Based Management supports Internet Explorer 6 0 or later version It utilizes Java Applets for reducing network bandwidth consumption enhancing access sp...

Page 53: ...Internet Explorer on the PC 2 Key in http the IP address of the switch and then Press Enter 3 The login screen will appear right after 4 Key in the user name and password The default user name and pa...

Page 54: ...800 260 1312 International 00 1 952 941 7600 47 Main Page The home page of the Web based screen mainly consists of a treeview control item For more details about each function please click the symbol...

Page 55: ...tem Description Displays the description of switch This column is read only cannot be modified System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter t...

Page 56: ...client is enabled the current IP will lose and user should find the new IP on the DHCP server IP Address Assign the IP address that the network is using If DHCP client function is enabled then user ne...

Page 57: ...range is from 192 168 1 100 192 168 1 200 192 168 1 100 will be the Low IP address High IP Address the dynamic IP assign range High IP address is the end of the dynamic IP assigns range For example dy...

Page 58: ...Technical Support 1 800 260 1312 International 00 1 952 941 7600 51 DHCP Client Client Entries When the DHCP server function is active the system will collect the DHCP client information and display...

Page 59: ...Port and IP Bindings You can assign the specific IP address that is the IP in the dynamic IP assign range to the specific port When the device is connected to the port and asks for dynamic IP assignin...

Page 60: ...are TFTP allows the user to update the switch firmware remotely via the network Before updating make sure you have your TFTP server ready and the firmware image is on the TFTP server 1 TFTP Server IP...

Page 61: ...uration You can restore the switch configuration from the TFTP server but you must put the image file on TFTP server first The switch will then download the flash image 1 TFTP Server IP Address Fill i...

Page 62: ...ckup Configuration You can save the current switch configuration from the switch to TFTP server then go to the TFTP restore configuration page to restore the switch configuration 1 TFTP Server IP Addr...

Page 63: ...em events that you want to record and the system log server IP 1 Syslog Client Mode Select the system log mode client only server only or both S C 2 System Log Server IP Address Assigned the system lo...

Page 64: ...r key in a complete email address e g switch101 123 com to identify where the event log comes from 4 Authentication mark the check box to enable and configure the email account and password for authen...

Page 65: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 58 SMTP Configuration interface...

Page 66: ...cold start When the device executes cold start action the system will issue a log event Device warm start When the device executes warm start the system will issue a log event Authentication Failure...

Page 67: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 60 Event Configuration interface...

Page 68: ...curs Please see the segment of Wiring the Fault Alarm Contact for reference With both power input 1 and power input 2 installed and the check boxes of power 1 power 2 ticked the FAULT LED indicator wi...

Page 69: ...d you need to configure the daylight saving time period 3 UTC Timezone Set the switch location time zone The following table lists the different location time zones for your reference Local Time Zone...

Page 70: ...edish Winter 1 hour 1 pm EET Eastern European USSR Zone 1 2 hours 2 pm BT Baghdad USSR Zone 2 3 hours 3 pm ZP4 USSR Zone 3 4 hours 4 pm ZP5 USSR Zone 4 5 hours 5 pm ZP6 USSR Zone 5 6 hours 6 pm WAST W...

Page 71: ...d 4 SNTP Sever URL Set the SNTP server IP address 5 Daylight Saving Period Set up the Daylight Saving beginning time and Daylight Saving ending time Both will be different in every year 6 Daylight Sav...

Page 72: ...hen be available Enable HTTP Server When this check box is checked the IP addresses among Security IP1 IP10 will be allowed to access via HTTP service Enable Telnet Server When checked the IP addresse...

Page 73: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 66 IP Security interface...

Page 74: ...7 User Authentication Here you can change login user name and password for management security 1 User name Key in the new user name The default is root 2 Password Key in the new password The default i...

Page 75: ...port Tx Bad Packet The counts of transmitting bad packets including undersize less than 64 bytes oversize CRC Align errors fragments and jabbers packets via this port Rx Good Packet The counts of rec...

Page 76: ...t to disable or enable mode If the port setting is disable then will not receive or transmit any packet 3 Negotiation set auto negotiation status of port 4 Speed set the port link speed 5 Duplex set f...

Page 77: ...are four trunk groups to be selected Choose the Group ID and click Select LACP When enabled the trunk group is using LACP A port which joins an LACP trunk group has to make an agreement with its memb...

Page 78: ...00 71 the left field To remove unwanted ports select the port and click Remove When LACP enabled you can configure LACP Active Passive status for each port on State Activity page Click Apply Use Delet...

Page 79: ...600 72 Aggregator Information When you have setup the aggregator setting with LACP disabled you will see the local static trunk group information in here 1 Group Key Displays the trunk group ID 2 Port...

Page 80: ...rt and click Apply the port state activity will change to Passive Active The port automatically sends LACP protocol packets Passive The port does not automatically send LACP protocol packets and respo...

Page 81: ...tion Port There is only one port that can be selected to be the destination mirror port for monitoring both RX and TX traffic which come from source port Or use one of two ports for monitoring RX traf...

Page 82: ...dcast only Broadcast Multicast Flooded Unicast Broadcast Multicast and Bbroadcast only types are selectable for ingress frames But the egress rate only supports All frame type Rate Limiting interface...

Page 83: ...only the members of the VLAN will receive traffic from the same VLAN members Basically creating a VLAN from a switch is logically equivalent to reconnecting a group of network devices to another Layer...

Page 84: ...station to send packets to different VLAN groups it itself has to be either capable of tagging packets it sends with VLAN tags or it must be attached to a VLAN aware bridge that is capable of classif...

Page 85: ...2 941 7600 78 VLAN Port Based Add interface You will see the VLAN displays Use Delete button to delete unwanted VLAN Use Edit button to modify existing VLAN group Note Remember to execute the Save Con...

Page 86: ...N Identifier VID that indicates the VLAN numbers You can create a Tag based VLAN and enable or disable GVRP protocol There are 256 VLAN groups If 802 1Q VLAN is Enabled then all ports on the switch be...

Page 87: ...the same VID to those ports Trunk Link The extended application of Access Link While the ports are set in this type they can forward the packets with specified tag among the switches which are include...

Page 88: ...works SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 81 Group Configuration interface 3 You can Change the VLAN group name and VLAN ID 4 Click Apply Group Configura...

Page 89: ...used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as the root The value must be a multiple of 4096 according to the protocol standard rule Max...

Page 90: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 83 RSTP System Configuration interface...

Page 91: ...re possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge i e it is served by a point to point LAN segment or can be connected to two or m...

Page 92: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 85 RSTP Port Configuration interface...

Page 93: ...twork devices implementing SNMP System Configuration Community Strings You can define a new community string set or remove unwanted community string 1 String Fill the name of string 2 RO Read only Ena...

Page 94: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 87 SNMP System Configuration interface...

Page 95: ...g the IP address of the station and a community string To define management stations as trap manager and enter SNMP community strings and selects the SNMP version 1 IP Address Enter the IP address of...

Page 96: ...P v3 context table Assign the context name of context table Click Add to add context name Click Remove to remove unwanted context name User Profile Configure SNMP v3 user table User ID Set up the user...

Page 97: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 90 SNMP V3 configuration interface...

Page 98: ...ccess table Context Prefix Set up the context name Group Name Set up the group Security Level Select the access level Context Match Rule Select the context match rule Read View Name Set up the read vi...

Page 99: ...igh queue will be processed at the same time in accordance with the 8 4 2 1 policy rule Use the strict priority scheme Always higher queue will be process first except higher queue is empty Priority T...

Page 100: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 93 QoS Configuration interface...

Page 101: ...Apply TOS Configuration Set up the TOS priority TOS priority the system provides 0 63 TOS priority level Each level has 4 types of priority egress queues high middle low and lowest The default value...

Page 102: ...switch asking for a response from each host belonging to the multicast group Report A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indic...

Page 103: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 96 IGMP Configuration interface...

Page 104: ...hes in the X Ring group If there are 2 or more switches in master mode then software will select the switch with lowest MAC address number as the ring master The X Ring master ring mode will be enable...

Page 105: ...u have to assign the control port to form a couple ring group between the two X rings Enable Dual Homing Set up one of the ports on the switch to be the Dual Homing port For a switch there is only one...

Page 106: ...thernet network devices such as switches routers and wireless LAN access points to advertise information about themselves to other nodes on the network and store the information they discover LLDP run...

Page 107: ...tion After enabling the IEEE 802 1X function you can configure the parameters of this function 1 IEEE 802 1x Protocol Enable or disable 802 1x protocol 2 Radius Server IP Set the Radius Server IP addr...

Page 108: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 101 802 1x System Configuration interface...

Page 109: ...specified port is required to be held in the unauthorized state Accept The specified port is required to be held in the Authorized state Authorized The specified port is set to the Authorized or Unaut...

Page 110: ...cation session 3 Supplicant Timeout Set the period of time the switch waits for a supplicant response to an EAP request 4 Server Timeout Set the period of time the switch waits for a server response t...

Page 111: ...ch from having to re learn a device s MAC address when the disconnected or powered off device is active on the network again You can add modify delete a static MAC address Add the Static MAC Address Y...

Page 112: ...Transition Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 105 Static MAC Addresses interface...

Page 113: ...AC addresses the switch can easily filter the pre configured MAC address and reduce insecurity You can add and delete filtering MAC address MAC Filtering interface MAC Address Enter the MAC address th...

Page 114: ...resses You can view all of the MAC addresses learned by the selected port Select the port number The selected port of static dynamic MAC address information will be displayed in here Click Clear MAC T...

Page 115: ...cluded in the specific multicast groups With multicast filtering network devices only forward multicast traffic to the ports that are connected to the registered end stations IP Address Assign a multi...

Page 116: ...M1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 109 Factory Default Reset switch to default configuration Click Reset to reset all configurations to the default value Fa...

Page 117: ...R Technical Support 1 800 260 1312 International 00 1 952 941 7600 110 Save Configuration Save all configurations that you have made in the system Click Save to save the all configuration to the flash...

Page 118: ...ion Networks SISGM1040 162D LR Technical Support 1 800 260 1312 International 00 1 952 941 7600 111 System Reboot Reboot the switch in software reset Click Reboot to reboot the system System Reboot in...

Page 119: ...or 100 Category 5e 6 cable for 1000Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators The Switch can be easily...

Page 120: ...3ad Port trunk with LACP IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1p Class of Service IEEE802 1Q VLAN Tag IEEE 802 1x User Authentication Radius IEEE802 1ab LLDP SNMP MIB RFC 1...

Page 121: ...FP sockets RS 232 interface RJ 45 type Network Cable 10 100 1000Base T 2 pair UTP STP Cat 5e 6 cable EIA TIA 568 100 ohm 100m SFP Mini GBIC Multi mode 50 125 m 62 5 125 m Single mode 9 125 m Protocol...

Page 122: ...x 152mm H EMI FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 S...

Page 123: ...nooping v1 v2 Up to 256 multicast groups and IGMP query Bandwidth control Ingress packets filter and egress packet limit The egress rate control supports all of packet type and the limit rate is in th...

Page 124: ...t link down Authentication Failure Private Trap for power status Port Alarm configuration Fault alarm X Ring topology change Relay Alarm One relay output for port breakdown and power fail Alarm Relay...

Page 125: ...gns represent the polarity of the wires that make up each wire pair The table below shows the 10 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Tra...

Page 126: ...Transition Networks SISGM1040 162D LR 119 Straight through cable schematic Cross over cable schematic 10 100 1000Base TX Pin outs The following figure shows the 10 100 1000 Ethernet RJ 45 pin outs...

Page 127: ...Transition Networks SISGM1040 162D LR 120 10 100 1000Base TX Cable Schematic Straight through cables schematic Cross over cables schematic...

Page 128: ...e the module is aligned correctly and then slide the module into the SFP slot until a click is heard You should use proper multi mode or single mode fiber according to the used SFP module Fiber optic...

Page 129: ...on Networks SISGM1040 162D LR 122 First insert the transceiver into the SFP slot Notice that the triangle mark is the bottom of the slot Figure 2 8 Transceiver to the SFP slot Figure 2 9 Transceiver I...

Page 130: ...Transition Networks SISGM1040 162D LR 123 Second insert the fiber cable of LC connector into the transceiver Figure 2 10 LC connector to the transceiver...

Page 131: ...please follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Figure 2 11 Remove LC connector Second push down the metal loop and...

Page 132: ...connection The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Fiber segment using single mode connector type must use 9 125 m single...

Reviews: