6
SGPOE10xx-1xx
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
DIP Switches
CAUTION: All installation and service must be performed by qualified service
personnel. Read and follow all warning notices and instructions marked on the product
and included in this manual.
Setting the configuration switches
The configuration switches are located on the back panel of the
SGPOE10xx-1xx media converters. Use a small, flat-blade
screwdriver to set the switches.
SW1. TP Auto-Negotiation: UP = Enable, DOWN = Disabled
SW2. TP Speed: UP = 100Mbs, DOWN =10Mbs
(SW1 DOWN Only)
SW3. TP Duplex: UP = Full, DOWN = Half
(SW1 DOWN Only)
SW4. PSE Enable: UP = ON, DOWN = Disabled
SW5. POE power off LPT: UP = Disabled, DOWN = Enabled
SW6. LPT: UP = Enable, DOWN = Disable
SW7. Unused
SW8. Unused
Down
Up
SW1. TP Auto-Negotiation: UP = Enable, DOWN Disabled
SW2. TP Speed: UP = 100Mbs, DOWN = 10Mbs
(SW1 DOWN only)
SW3. TP Duplex: UP = Full, DOWN = Half
(SW1 DOWN only)
SW4. Fiber 1 Mode: 1000X/SGMII, UP = 1000X, DOWN = SGMII
SW5. Fiber 1: Speed, UP = 1000Mbs, DOWN = 100Mbs
(SW4 UP only)
SW6. Fiber 1: Duplex, UP = Full, DOWN = Half
(SW4 UP, SW5 DOWN only)
SW7. PSE Power: UP = Enabled, DOWN = Disabled
SW8. PSE/LTP Power: UP = Disabled, DOWN = Enabled
SW9. LTP: UP = Disabled, DOWN = Enabled
(NA when Fiber Redundancy Enabled)
SW10. Unused
Up
Down
SFP Single: SGPOE1040-100
Switch
Key
Up
Down
[email protected] -- Click the “Transition Now” link for a live Web chat.
7
SFP Dual: SGPOE1040-110
SW1. TP Auto-Negotiation: UP = Enable, DOWN Disabled
SW2. TP Speed: UP = 100Mbs, DOWN = 10Mbs
(SW1 DOWN only)
SW3. TP Duplex: UP = Full, DOWN = Half
(SW1 DOWN only)
SW4. Fiber 1 Mode: 1000X/SGMII, UP = 1000X, DOWN = SGMII
SW5. Fiber 1: Speed, UP = 1000Mbs, DOWN = 100Mbs
(SW4 UP only)
SW6. Fiber 1: Duplex, UP = Full, DOWN = Half
(SW4 UP, SW5 DOWN only)
SW7. PSE Power: UP = Enabled, DOWN = Disabled
SW8. Unused
SW9. Unused
SW10. Unused
SW1. Fiber 2 1000X/SGMII: UP = 1000X, DOWN = SGMII
SW2. Fiber 2 Speed: UP = 1000Mbs, DOWN = 100Mbs
(only in 1000x mode, SW1 UP)
SW3. Fiber 2 Duplex: UP = Full, DOWN = Half
(SW11 UP, SW12 DOWN)
SW4. Redundancy: UP = Disabled, DOWN = Enabled
Up
Down
Installation -- Continued
Setting the configuration switches -- continued