2
SGFEB10xx-12x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
SGFEB1029-120
RJ-45
100 m
(328 ft)
SC, 1310nm TX/1550nm RX single mode
20 km
(12.4 miles)
SGFEB1029-121
RJ-45
100 m
(328 ft)
SC, 1550nm TX/1310nm RX single mode
20 km
(12.4 miles)
Install SGFEB1029-120 and SGFEB1029-121 single-fiber optic in
the same network where one is the local converter and the other is
the remote converter.
SGFEB1029-122
RJ-45
100 m
(328 ft)
SC, 1310nm TX/1550nm RX single mode
40 km
(24.9 miles)
SGFEB1029-123
RJ-45
100 m
(328 ft)
SC, 1550nm TX/1310nm RX single mode
40 km
(24.9 miles)
Install SGFEB1029-122 and SGFEB1029-123 single-fiber optic in
the same network where one is the local converter and the other is
the remote converter.
Part Number
Port 1 - Copper
10/100/1000Base-T
Port 2 - Duplex Fiber-Optic
1000Base LX
Wide Input
(18 – 72VDC)
Power Supplies
SPS-1872-PS or SPS-1872-SA
Mounting Options
E-MCR-04
12-Slot Media Converter Rack
WMBD
DIN Rail Mount Bracket 5.0 inches
(127 mm)
WMBL
Wall Mount Bracket 4.0 inches
(102 mm)
RMS19-SA4-01
4-Slot Media Converter Shelf
Optional accessories
SGFEB1029-126
RJ-45
100 m
(328 ft)
SC, 1510nm TX/1590nm RX single mode
80 km
(49.6 miles)
SGFEB1029-127
RJ-45
100 m
(328 ft)
SC, 1590nm TX/1510nm RX single mode
80 km
(49.6 miles)
Install SGFEB1029-126 and SGFEB1029-127 single-fiber optic in
the same network where one is the local converter and the other is
the remote converter.
SGFEB10xx-12x
[email protected] -- Click the “Transition Now” link for a live Web chat.
3
Installation
CAUTION: Wear a grounding device and observe electrostatic discharge precautions
when handling the media converter. Failure to observe this caution could result in
damage to, and subsequent failure of, the media converter slide-in-module.
Six-position switch
The six-position switch is located on the circuit board of the media converter. Use a
small, flat-blade screwdriver
(or a similar device)
to set the switch according to the
site requirements
(see the drawing below)
.
TP Speed: UP =100 Mbs, Down = 10 Mbs
(Note 1)
TP Auto-Negotiation: UP = Enabled, Down = Disabled
TP Duplex: UP = Full, Down = Half
(Note 1)
LPT: UP = Enabled, Down = Disabled
Unused
SW Position Up
SW Position Down
Unused
1 2 3 4 5 6
Note 1:
Only use when Auto-Negotiation is disabled.
1. TP Auto-Negotiation
UP
Enable Auto-Negotiation for the copper connection.
DOWN Disable Auto-Negotiation for the copper connection.
2. TP Speed 10Mbs/100Mbs
UP
Set copper connection speed to 100Mbs.
DOWN Set copper connection speed to 10Mbs.
3. TP Full/Half Duplex
UP
Operate in full-duplex mode.
DOWN Operate in half-duplex mode of the attached device.
4. Link Pass-Through (LPT)
UP
Enable Link Pass-Through
DOWN Disable Link Pass-Through.
5. Not used
6. Not used