Transition Networks SBFTF10xx-1xx User Manual Download Page 18

Transition Networks 

 

 

 

 

 

 

SBFTF10xx-10x User Guide 

33404 Rev. G 

https://www.transition.com 

Page 18 of 18 

Canadian regulations 

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio 

interference regulations of the Canadian Department of Communications. 
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux 

appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le 

ministère des Communications du Canada. 

European regulations 

Warning 
This is a Class A product. In a domestic environment this product may cause radio interference in which case the 

user may be required to take adequate measures. 
Achtung ! 
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes 

Rundfunkstörungen auftreten. In diesem Fäll is der Benutzer für Gegenmaßnahmen verantwortlich. 

Attention ! 
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences 

radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées. 

 
In accordance with European Union Directive 2002/96/EC of the European Parliament and of the 
Council of 27 January 2003, Transition Networks will accept post usage returns of this product for 

proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of 

this document. 

 

CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to 

observe this caution could result in damage to the public telephone network. 
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EGMitgliedstaaten verstösst 

gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der 

Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der 

gegenseitigen Anerkennung ihrer Konformität. 

Record of Revisions 

 

Rev 

Date 

Notes 

6/5/08 

Initial release. 

12/5/08 

Switch positions 2 and 3 swapped: Speed and Duplex. Added part # SBFTF1040-105 

4/16/09 

Switch position FEF and LPT SW5 and SW6 reversed.  

9/30/09 

Added part number SBFTF1029-109. Removed VCCI statement from compliance section. 

10/14/10  Corrected the link budgets on SBFTF1015, 16, 17-105. 

8/17/11 

Revised Declaration of Conformity. 

10/14/16  Revised for FW Rev. B. Changed format and specifications. 

 

 

Trademark notice: All trademarks and registered trademarks are the property of their respective owners. 

 

Copyright restrictions: © 2008-2016 Transition Networks. All rights reserved. No part of this work may be reproduced or used 

in any form or by any means - graphic, electronic or mechanical - without written permission from Transition Networks. 

 

 

Summary of Contents for SBFTF10xx-1xx

Page 1: ...onnect the Fiber Cable 5 Power the Media Converter 5 Product Features 6 Operation 8 Status LEDs 8 Half Duplex Network 9 Cable Specifications 12 Technical Specifications 14 Troubleshooting 15 Contact U...

Page 2: ...2 mi Link Budget 11 0 dB SBFTF1040 105 10 100Base TX RJ 45 100 m 328 ft to 100Base X SFP Slot empty Typical maximum cable distance Actual distance is dependent upon the physical characteristics of the...

Page 3: ...to Negotiation on the copper port down Disables Auto Negotiation on the copper port Forces the setting of switches 2 and 3 2 TP Duplex Only functions with switch 1 down up Full duplex operation on the...

Page 4: ...Fast Ethernet Collision Domain If half duplex cable is used refer to the 512 Bit Rule before installing the 100Base TX twisted pair copper cable If full duplex cable is used the 512 Bit Rule does not...

Page 5: ...nect the male TX cable connector to the female TX port Connect the male RX cable connector to the female RX port 3 Connect the fiber cables to the other device another media converter hub etc as descr...

Page 6: ...between the two devices e g 10 Mb s half duplex Disabling this feature lets you force the connection to the desired speed and duplex mode of operation AutoCross When the AutoCross feature is activate...

Page 7: ...it Rule applies separately to each collision domain In a full duplex Ethernet or Fast Ethernet environment the SBFTF10xx 10x media converter extends network distances to the physical cable limitations...

Page 8: ...media converter operation in the network LED Description Pwr Power ON Power applied OFF Not powered Fiber LEDs LNK ACT Link Activity ON Solid Link established FLashing RX Data FD Duplex ON Full Duplex...

Page 9: ...he collision domain i e the longest path between any two terminal devices e g terminal switch and or router 2 Calculate the round trip delay in bit times for each length of cable 3 Determine the bit t...

Page 10: ...Rule 10Base T Use the 5 Segment Rule to calculate the 10Base T half duplex collision domain The 5 Segment Rule states that a transmission path of a collision domain can consist of not more than 5 seg...

Page 11: ...t Rule The cable between each network device media converter Hub or Terminal is numbered as a segment Note that the longest transmission path from the media converter at the top to the terminal at the...

Page 12: ...er Power min 5 0 dBm max 2 0 dBm Fiber optic Receiver Sensitivity min 34 0 dBm max 7 0 dBm Link Budget 29 0 dB SBFTF1016 105 single mode Fiber optic Transmitter Power min 4 0dBm max 2 0 dBm Fiber opti...

Page 13: ...Copper cable maximum cable distance 100 meters Category 3 Minimum requirement for 10 Mb s operation Gauge 24 to 22 AWG Attenuation 11 5 dB 100m 5 10 MHz Category 5 Minimum requirement for 100 Mb s ope...

Page 14: ...ormation on the SBFTF10xx 10x see the online user guide at https www transition com WARNING Visible and invisible laser radiation when open Do not stare into the beam or view the beam directly with op...

Page 15: ...Technical Support see Contact Us below YES Proceed to step 3 3 Is the FD LNK fiber pair link LED lit NO Check the fiber cables for proper connection Verify that the TX and RX cables are connected to...

Page 16: ...00 Mb mode Contact Tech Support see Contact Us below YES Contact Tech Support see Contact Us below Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 260 13...

Page 17: ...are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency ene...

Page 18: ...etworks will accept post usage returns of this product for proper disposal The contact information for this activity can be found in the Contact Us portion of this document CAUTION RJ connectors are N...

Reviews: