Transition Networks SBFTF1011-140 User Manual Download Page 5

8

SBFTF10xx-14x

Tech Support: 

1-800-260-1312

International: 

00-1-952-941-7600

(24 hours)

Installation 

-- Continued

Power the Media Converter  

NOTE:

The external power supply provided with this product is UL listed by

the power supply’s manufacturer.

AC

1.

Connect the barrel connector on the power adapter to the media
converter’s power port (located on the back of the media converter). 

2.

Connect the power adapter plug to AC power.

3.

Verify that the media converter is powered by observing the illuminated
LED power indicator light.

DC

Consult the user’s guide for the Transition Networks SPS1872-xx DC external
power supply for powering the media converter.

Operation

Status LEDs

Use the status LEDs next to the fiber ports to monitor the media converter and
the 

fiber network 

connections.  

F(ull) D(uplex)

On = Full-duplex connection.

Off = Half-duplex connection.

L(ink) ACT(ivity)

On = Fiber link connection.

Flashing = Fiber network activity.

P(o)W(e)R

On = Connection to external AC or DC power.

FD

LACT

PWR

FD

LACT

The “FD” and “LACT” LEDs near the top of the media
converter refer to 

Fiber Port 2 (F2)

.

The “FD” and “LACT” LEDs near the bottom of the media
converter refer to 

Fiber Port 1 (F1)

.

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

9

Operation 

-- Continued

Status LEDs -- Continued

Use the bi-color twisted-pair status LEDs to monitor the 

twisted-pair copper

network 

connections.  

Duplex/Link LED

Amber = A link in 

half-duplex

mode has been

established for the twisted-pair copper link.

Flashing Amber = Activity on the 

half-duplex

copper link.

Green = A link in 

full-duplex

mode has been

established for the twisted-pair copper link.

Flashing Green = Activity on the 

full-duplex

copper link.

Speed LED

Amber  = 10Mb/s operation.

Green = 100Mb/s operation.

Product Features

Full-Duplex Network

In a full-duplex network, maximum cable lengths are determined by 

the type

of cables 

that are used.  See pages 1 and 2 for the cable specifications for the

different SBFTF10xx-14x models.  

The 512-Bit Rule 

does not apply

in a full-duplex network.

Half-Duplex Network (512-Bit Rule)

In a half-duplex network, the maximum cable lengths are determined by the
round trip delay limitations of each Fast Ethernet 

collision domain

.  (A

collision domain is the longest path between any two terminal devices, e.g.  a

terminal

switch

, or 

router

.) 

The 512-Bit Rule determines the maximum length of cable permitted by
calculating the round-trip delay in 

bit-times (BT)

of a particular collision

domain.  If the result is less than or equal to 512 BT, the path is good.  

For more information on the 512-Bit Rule, see the white paper titled
“Collision Domains” on the Transition Networks website at:
www.transition.com.

Duplex/Link  Speed

10/100TX

Summary of Contents for SBFTF1011-140

Page 1: ...haul RJ 45 100 m 328 ft SC 1310 nm single mode 40 km 24 8 miles SBFTF1016 140 extra long haul RJ 45 100 m 328 ft SC 1310 nm single mode 60 km 37 2 miles SBFTF1017 140 long wave length RJ 45 100 m 328...

Page 2: ...r ports and the two 2 fiber ports Installation Continued Set the Dip Switches The dip switches are located on the side of the media converter Use a small flat blade screwdriver or a similar device to...

Page 3: ...4 AutoCross Enable AutoCross Disable UP 5 DOWN techsupport transition com Click the Transition Now link for a live Web chat 5 Installation Continued Set the Dip Switches Continued NOTE Dip switches 1...

Page 4: ...er to the 512 Bit Rule see page 9 If full duplex mode is used the 512 Bit Rule does not apply The cable lengths are constrained by the cable requirements see pages 1 and 2 Connect the Fiber Cable 1 Lo...

Page 5: ...eration Continued Status LEDs Continued Use the bi color twisted pair status LEDs to monitor the twisted pair copper network connections Duplex Link LED Amber A link in half duplex mode has been estab...

Page 6: ...tween the two devices e g 10 Mb s half duplex Disabling this feature gives the user the ability to force the connection to the desired speed and duplex mode of operation techsupport transition com Cli...

Page 7: ...Power min 8 0 dBm max 3 0 dBm Fiber optic Receiver Sensitivity min 33 0 dBm max 3 0 dBm Link Budget 25 0 dB The fiber optic transmitters on this device meets Class I Laser safety requirements per IEC...

Page 8: ...in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference...

Page 9: ...by sending an e mail to our technical support staff techsupport transition com Address Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA telephone 952 941 7600 toll free 800 526 9267...

Reviews: