Transition Networks SBFTF1011-140 User Manual Download Page 2

2

SBFTF10xx-14x

Tech Support: 

1-800-260-1312

International: 

00-1-952-941-7600

(24 hours)

*

Typical maximum cable distance.  Actual distance is dependent upon the
physical characteristics of the network.  (TX) = transmit   (RX) = receive

SBFTF1029

-140

and SBFTF1029

-141

are intended to be installed in the same

network where one is the 

local

converter and the other is the 

remote

converter.

SBFTF1029

-142

and SBFTF1029

-143

are intended to be installed in the same

network where one is the 

local

converter and the other is the 

remote

converter.

The 

chassis version

of this media converter is CBFTF10xx-14x.  For more

information, see the CBFTF10xx-14x user’s guide on-line at:  www.transition.com.

Part Number

Copper - 

four (4) ports

10Base-T/100Base-TX

Fiber-Optic - 

two (2) ports

Single Fiber

SBFTF1029-140

RJ-45
100 m (328 ft)*

SC, 1310 nm (TX)/1550 nm (RX)
single mode, 20 km (12.4 miles)* 

SBFTF1029-141

RJ-45
100 m (328 ft)*

SC, 1550 nm (TX)/1310 nm (RX)
single mode, 20 km (12.4 miles)*

SBFTF1029-142

RJ-45
100 m (328 ft)*

SC, 1310 nm (TX)/1550 nm (RX)
single mode, 40 km (24.8 miles)*

SBFTF1029-143

RJ-45
100 m (328 ft)*

SC, 1550 nm (TX)/1310 nm (RX)
single mode, 40 km (24.8 miles)*

10/100TX

10/100TX

10/100TX

10/100TX

100Base-FX

100Base-FX

FD

LACT

PWR

Twisted-Pair

Port 1 (TP1)

Twisted-Pair

Port 2 (TP2)

FD

LACT

Twisted-Pair

Port 3 (TP3)

Twisted-Pair

Port 4 (TP4)

Fiber Port 2

(F2)

Fiber Port 1

(F1)

Installation

Copper and Fiber Ports

The figure below illustrates the locations of the four (4) twisted-pair copper ports
and the two (2) fiber ports.  

Installation 

-- Continued

Set the Dip Switches

The dip switches are located on the side of the media converter.  Use a small,
flat-blade screwdriver or a similar device to set each dip switch.  

“SW1” switches 1 - 6

Dip switches 1, 2, and 3 apply only to twisted-pair copper port 1 (TP1).  

Dip switch 4 applies to fiber port 1 (F1).  

Dip switch 5 applies to all twisted-pair copper ports (TP1, TP2, TP3, TP4).  

Dip switch 6 applies to both fiber ports (F1, F2).  

“Config. Switches” 1 - 4

Dip switches 1, 2, 3, and 4 apply 

only

to twisted-pair copper port 2 (TP2).  

NOTE:  

Switches 1, 2, and 3 apply 

only

to twisted-pair 

copper port 1 (TP1)

.  

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

3

1.  Twisted-Pair Auto-Negotiation

Up (Enabled)

- The media converter “advertises”

ALL rate and mode capabilities to the network:  

• 100Mb/s full-duplex  • 100Mb/s half-duplex,
• 10Mb/s full-duplex    • 10Mb/s half-duplex.  

Down (Disabled)

- The bridging media converter

does not “advertise” the rate and mode
capabilities to the network.  

Switches 2

and

3

are

then used to set the twisted-pair rate and mode.  

2.  Twisted-Pair Rate 

Up (100Base-TX)

- Sets the twisted-pair rate to

100Base-TX.

Down (10Base-T)

- Sets the twisted-pair rate to

10Base-T.

3.  Twisted-Pair Mode 

Up (Full-Duplex) 

- The twisted-pair cable

distances are constrained by the cable
requirements (see pages 1 and 2).

Down (Half-Duplex):

- The twisted-pair cable

distances are constrained by the 512-Bit Rule (see
page 9).  

DOWN

1

UP

2

Twisted-Pair Auto-Negotiation ON

Twisted-Pair Auto-Negotiation OFF

Twisted-pair 100Base-TX

Twisted-pair 10Base-T

DOWN

UP

2

Twisted-pair Full-Duplex

Twisted-pair Half-Duplex

DOWN

UP

3

Summary of Contents for SBFTF1011-140

Page 1: ...haul RJ 45 100 m 328 ft SC 1310 nm single mode 40 km 24 8 miles SBFTF1016 140 extra long haul RJ 45 100 m 328 ft SC 1310 nm single mode 60 km 37 2 miles SBFTF1017 140 long wave length RJ 45 100 m 328...

Page 2: ...r ports and the two 2 fiber ports Installation Continued Set the Dip Switches The dip switches are located on the side of the media converter Use a small flat blade screwdriver or a similar device to...

Page 3: ...4 AutoCross Enable AutoCross Disable UP 5 DOWN techsupport transition com Click the Transition Now link for a live Web chat 5 Installation Continued Set the Dip Switches Continued NOTE Dip switches 1...

Page 4: ...er to the 512 Bit Rule see page 9 If full duplex mode is used the 512 Bit Rule does not apply The cable lengths are constrained by the cable requirements see pages 1 and 2 Connect the Fiber Cable 1 Lo...

Page 5: ...eration Continued Status LEDs Continued Use the bi color twisted pair status LEDs to monitor the twisted pair copper network connections Duplex Link LED Amber A link in half duplex mode has been estab...

Page 6: ...tween the two devices e g 10 Mb s half duplex Disabling this feature gives the user the ability to force the connection to the desired speed and duplex mode of operation techsupport transition com Cli...