2
J/E-PSW-FX-02
24-Hour Technical Support:
1-800-260-1312
-- International:
00-1--952-941-7600
Installation
CAUTION:
Wear a grounding device and observe electrostatic discharge
precautions when setting the 4-position switch. Failure to observe this caution
could result in damage to the media converter.
Setting the 4-position switch
The 4-position switch is located on the
rear panel of the media converter. Use
a small, flat-blade screwdriver to set
the recessed switches.
(See the
drawing to the right.)
1. Auto-Negotiation
UP
Enables Auto-Negotiation on the copper port.
Advertises 100 Mb/s full-duplex and half duplex,
and 10 Mb/s full-duplex and half duplex.
DOWN
Disables Auto-Negotiation on the copper port.
2. Copper Mode
(Applies only if switch 1 is DOWN.)
UP
Forces full-duplex operation on the copper port.
DOWN
Forces half-duplex operation on the copper port.
3. Speed
(Applies only if switch 1 is DOWN.)
UP
Forces 100 Mb/s operation on the copper port.
DOWN
Forces 10 Mb/s operation on the copper port.
4. Fiber Mode
UP
Forces full-duplex operation on the fiber port.
DOWN
Forces half-duplex operation on the fiber port.
Speed (up=100Mb/s)
Copper Mode (up=Full-Duplex)
Auto-Negotiation (up=Enabled)
Fiber Mode
(up=Full-Duplex)
1 2 3 4
-- Click the
“Transition Now”
link for a live Web chat.
3
Installation
-- Continued
Installing the fiber cable
1.
Locate IEEE 803.2
™
compliant 100Base-FX fiber cable with male, two-
stranded TX to RX connectors installed at both ends.
2.
Connect the fiber cables to the J/E-PSW-FX-02 media converter as
described:
•
Connect the male TX cable connector the female TX port.
•
Connect the male RX cable connector to the female RX port.
3.
Connect the fiber cables to the other device
(another media converter,
hub, etc.)
as described:
•
Connect the male TX cable connector the female RX port.
•
Connect the male RX cable connector to the female TX port.
Connect the fiber cable
to the media converter
as shown.
Connect the fiber cable
to the other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
Installing the twisted-pair copper cable
1.
Locate or build IEEE 803.2
™
compliant 10Base-T or 100Base-TX cables,
with male RJ-45 connectors installed at both ends.
2.
Connect the RJ-45 connector at one end of the cable to the RJ-45 port on
the media converter.
3.
Connect the RJ-45 connector at the other end of the cable to the RJ-45
port on the other device
(switch, workstation, etc.).
NOTE:
The MDI
(straight-through)
or MDI-X
(crossover)
cable connection is
configured automatically, according to the network conditions.
RJ-45 port
on the other device
(switch, work station, etc.)
RJ-45 port
on the media
converter