Transition Networks E-TBT-MC03 User Manual Download Page 4

OPERATION 

After installation, the transceiver should function without operator intervention. 

Status LEDs

Use the status LEDs to monitor transceiver operation in the network. 

STATUS  

ON=OK

Steady green
LED indicates
normal
operation.
Link Down:
One (1)
continuous,
flashing blink indicates no data packet or link
integrity pulse being received over twisted-pair.
Local Jabber: Two (2) continuous, flashing blinks
indicate AUI packets are too long.
Polarity Reversed: Five (5) continuous, flashing blinks
indicate receive pair has the wrong polarity.  The
transceiver automatically corrects this condition if
switch 3 is UP.  This warning will continue until the
wiring is corrected.
Dark LED indicates NO connection to external
power.

C0L(lision):

Illuminated amber LED indicates signal collisions on the
Ethernet cable.

TX

Flashing or illuminated amber LED indicates packet
transmission (AUI to twisted-pair).

RX

Flashing or illuminated amber LED indicates packet
reception (twisted-pair to AUI).

FAULT ISOLATION and CORRECTION

If the transceiver fails, determine the answers to the following questions:

1.

Is the STATUS LED on the transceiver illuminated?
NO

Verify that the transceiver is installed properly in the AUI port and
that the DTE device is powered ON?

Contact Technical Support at (800) 260-1312/(800) 526-9267.

YES

Proceed to step 2.

2.

Is the RX LED illuminated?
NO

Check twisted pair cables for proper connection.

Contact Technical Support at (800) 260-1312/(800) 526-9267.

YES

Proceed to step 3.

3.

Is the TX LED illuminated?
NO

Check AUI cables for proper connection.

Restart the workstation to restart the initialization process.

Contact Technical Support at (800) 260-1312/(800) 526-9267.

YES

Contact Technical Support at (800) 260-1312/(800) 526-9267.

STATUS

RX

TX

COL

ON = OK