E-TBT-MC03 IN THE NETWORK

NOTE: AUI cable can be used to connect to the transceiver.  

Using LinkAlert™

The LinkAlert™ feature allows the transceiver to pass 10BASE-T-side link faults
to the AUI side and to pass AUI-side link faults to the 10BASE-T side.

If the channel does not detect a good link on the 10BASE-T side, the transceiver
disables all transmission (including active-idle) on the AUI side AND the
STATUS LED on the transceiver blinks twice. 

TECHNICAL SPECIFICATIONS

Standards

IEEE 802.3

Case Dimensions

1.65" x 3.10" x 0.94"

(42 mm x 79 mm x 24 mm)

Weight

3.4 oz. (96.5 g)

Environment

Temperature:

0-40°C (32° to 104° F )

Humidity

10-90%, non condensing 

Altitude

0-10,000 feet

Power

11.4 - 16.5 VDC, 
75 mA (typical), 200 mA (maximum)

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

AUI/10BASE-T Transceiver

Part Number:

E-TBT-MC03

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the E-TBT-MC03 to which this declaration refers is in

conformity with the following standards.

EMC-CISPR 22: 1985 Class A;  EN 55022: 1988 Class A;  EN 50082-1:1992;
EN 60950 A4:1997;  IEC 801.2, IEC 801.3, and IEC 801.4;  IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_August 11, 1999_____

Stephen Anderson, Vice-President of Engineering

Date

10BASE-T Hub

OR

OR

Hub with MII connector

SQE = ON

ST

A

TUS

RX

TX

COL

ON = OK

ST

A

TUS

RX

TX

COL

ON = OK

ST
A

TUS

RX

TX

COL

ON = OK

SQE = OFF

SQE = ON

10BASE-T

Device

Transceiver

FAR END FAULT INDICATION*

LINK FAULT INDICATION

Network

Device