E-PSW-SX-01

Connecting Twisted-Pair Copper Cable to UTP/STP
Connector (10BASE-T/100BASE-TX)

Ensure that the correct cable type is installed to support the highest speed
and mode of operation to be selected. Though Category 3 cable is
adequate for the 10BASE-T installation, Category 5 cable is strongly
recommended, since Category 3 cable can NOT be used for 100BASE-TX.

10BASE-T AND THE ETHERNET COLLISION DOMAIN

Refer to the 5-Segment Rule (page 6) before installing half-duplex
10BASE-T cable.

Installing full-duplex twisted-pair cable avoids collision domain
considerations; distances remain 

100 meters. 

100BASE-TX AND THE FAST ETHERNET COLLISION DOMAIN

Refer to the 512-Bit Rule (page 7) before installing half-duplex
100BASE-TX cable.

Installing full-duplex twisted-pair cable avoids collision domain
considerations; distances remain 

100 meters. 

NOTE: A Fast Ethernet collision domain can have ONLY ONE
CLASS I repeater OR TWO CLASS II repeaters.

INSTALLING CABLE
To install 10BASE-T or 100BASE-TX cable:

1. Locate or build 10BASE-T or 100BASE-TX cables:

803.2 (10BASE-T) or 803.2u (100BASE-TX) compliant (page

11)

with Straight-through or Crossover RJ-45 cable/connectors as

required for site installation (page 7)

with RJ-45 plug connectors installed at both cable ends.

2. Connect RJ-45 plug connector at one end of 10BASE-T or

100BASE-TX cable to bridging media converter RJ-45 jack
connector.

3. Connect RJ-45 plug connector at other end of 10BASE-T or

100BASE-TX cable to RJ-45 jack connector on network device.

EXAMPLE DIP SWITCH SETTINGS:

TWISTED-PAIR AUTO-NEGOTIATION:

Set auto-negotiation (DIP switch #1) to select auto-
negotiation: ON=UP

Set twisted-pair full-duplex/half-duplex (DIP switch #2) to
select full-duplex: ON=UP

Set twisted-pair 10BASE-T/100BASE-TX (DIP switch #3) to
select 100BASE-TX: ON=UP

TWISTED-PAIR FULL-DUPLEX 100BASE-TX:

Set auto-negotiation (DIP switch #1) to de-select auto-
negotiation: OFF=DOWN

Set twisted-pair full-duplex/half-duplex (DIP switch #2) to
select full-duplex: ON=UP

Set twisted-pair 10BASE-T/100BASE-TX (DIP switch #3) to
select 100BASE-TX: ON=UP

TWISTED-PAIR 10BASE-T WITH MODE AUTO-NEGOTIATION:

Set auto-negotiation (DIP switch #1) to select auto-
negotiation: ON=UP

Set twisted-pair full-duplex/half-duplex (DIP switch #2) to
select full-duplex: ON=UP

Set twisted-pair 10BASE-T/100BASE-TX (DIP switch #3) to
select 10BASE-T: OFF=DOWN

FIBER FULL-DUPLEX 100BASE-SX:

Set fiber full-duplex/half-duplex (DIP switch #4) to select
full-duplex: ON=UP

FIBER HALF-DUPLEX 100BASE-SX:

Set fiber full-duplex/half-duplex (DIP switch #4) to select
half-duplex: OFF=DOWN

UP UP UP

DOWN

UP UP

UP

UP

DOWN

UP

DOWN

Summary of Contents for E-PSW-SX-01(SC)

Page 1: ...erty of their respective owners 33103 B Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität Pow...

Page 2: ...stics of 100BASE TX cable must meet or exceed IEEE 802 3 100BASE TX specifications Category 5 cable or better is required Either shielded twisted pair STP or unshielded twisted pair UTP can be used DO NOT USE FLAT OR SILVER SATIN WIRE Category 3 Gauge 24 to 22 AWG Attenuation 6 5 dB 100 10 MHz Differential Characteristic Impedance 100 Ω 15 Category 5 Gauge 24 to 22 AWG Attenuation 22 dB 100 100 MH...

Page 3: ...eck fiber cables for proper connection Verify that TX and RX cables are connected to RX and TX ports respectively on 100BASE SX device Refer to Tech Tips available at http www transition com Contact Technical Support YES Contact Technical Support 800 260 1312 800 LAN WANS E PSW SX 01 3 10 Link UTP STP Fiber Link FDX Power 100 Link UTP STP Fiber Link FDX Power 100 100BASE TX 10BASE T 100BASE SX CON...

Page 4: ...tances up to 300 meters NOTE A Fast Ethernet collision domain can have ONLY ONE CLASS I repeater OR TWO CLASS II repeaters INSTALLING CABLE To install 100BASE SX cable 1 Locate or build 100BASE SX cables 100BASE SX compliant page 11 with male transmit TX and receive RX fiber connectors installed at both cable ends 2 Connect transmit cable connector at one end of fiber cable to bridging media conve...

Page 5: ... page 7 with RJ 45 plug connectors installed at both cable ends 2 Connect RJ 45 plug connector at one end of 10BASE T or 100BASE TX cable to bridging media converter RJ 45 jack connector 3 Connect RJ 45 plug connector at other end of 10BASE T or 100BASE TX cable to RJ 45 jack connector on network device EXAMPLE DIP SWITCH SETTINGS TWISTED PAIR AUTO NEGOTIATION Set auto negotiation DIP switch 1 to ...

Page 6: ...parates collision domain so the 512 bit rule applies separately to each 100BASE TX or 100BASE SX half duplex collision domain A segment is the cable connection between interfaces A transmission path between any two terminal devices including the Transition Networks Switch in the same collision domain can consist of no more than five segments To assign segment numbers to cable connections determine...

Reviews: