Transition Networks CRS4Fxxxx-10x User Manual Download Page 2

2

Tech Support: 1-800-260-1312   International: 00-1-952-941-7600   (24 hours)

CRS4Fxxxx-10x

Part Number

Part One - Copper 
DB-9 Port

Port Two - Fiber Optic

CRS4F3129-100

RS485
1200 m

(4000 ft)*

SC, 1310TX/1550RX nm, single mode
20 km 

(12.4 miles)**

CRS4F3129-101

RS485
1200 m

(4000 ft)*

SC, 1550TX/1310RX nm, single mode
20 km 

(12.4 miles)**

CRS4F3129-102

RS485
1200 m

(4000 ft)*

SC, 1310TX/1550RX nm, single mode
40 km 

(24.8 miles)**

CRS4F3129-103

RS485
1200 m

(4000 ft)*

SC, 1550TX/1310RX nm, single mode
40 km 

(24.8 miles)**

Part Number

Part One - Copper -6-
position terminal block

Port Two - Fiber Optic

CRS4F3229-100

RS485
1200 m

(4000 ft)*

SC, 1310TX/1550RX nm, single mode
20 km 

(12.4 miles)**

CRS4F3229-101

RS485
1200 m

(4000 ft)*

SC, 1550TX/1310RX nm, single mode
20 km 

(12.4 miles)**

CRS4F3229-102

RS485
1200 m

(4000 ft)*

SC, 1310TX/1550RX nm, single mode
40 km 

(24.8 miles)**

CRS4F3229-103

RS485
1200 m

(4000 ft)*

SC, 1550TX/1310RX nm, single mode
40 km 

(24.8 miles)**

The CRS4F3129-10x media converters use a male DB-9 port for the copper link: 

The CRS4F32xx-10x media converters use a 6-position terminal block for the copper link: 

*

Maximum cable distance is 1200m

(4000 ft)

@ <90 kb/s decreasing logarithmically to

92m 

(300 ft)

@ 500 kb/s.

**Typical maximum cable distance.  Actual distance is dependent upon the physical

characteristics of the network installation.

[email protected] -- Click the “Transition Now” link for a live Web chat.

3

Installation

CAUTION: Wear a grounding device and observe electrostatic discharge precautions
when setting the switches.  Failure to observe this caution could result in damage to,
and subsequent failure of, the media converter.

Set the 6-Position Switch

The 6-position switch is located on the side of the media converter.  Use a small flat-
blade screwdriver or a similar device to set the recessed switches.  Refer to the
drawing for the locations of the six individual switches.  

Switch 1 - 130 ohm resistor on “receive”

up

= Disable

down

= Enable  

(Switch 5 must also be set to “4-wire” (down)

When enabled, switch 1 inserts a 130 ohm resistor on the wire pair:

Receive (-) (B) RS485 4-wire, receive (-) RS422

Receive (+) (A) RS485 4-wire, receive (+) RS422

Switch 2 - 130 ohm resistor on “transmit”

up

= Disable

down

= Enable.  

(Switch 5 must also be set to “2-wire” (up)

When enabled, switch 2 inserts a 130 ohm resistor on the wire pair:

Transmit/Receive (-) (B) RS485 2-wire, transmit (-) RS422 

Transmit/Receive (+) (A) RS485 2-wire, transmit (+) RS422

Switch 3 - 1K ohm “pull-down”

up

= Disable

down

= Enable.  

(Switch 5 must also be set to “2-wire” (up)

When enabled, switch 3 enables a 1K ohm pull-down on the wire:

Transmit/Receive (-) (B) RS485 2-wire, transmit (+) RS422

130 Ohm Resistor on Receive

1K Ohm Pull-Down

1K Ohm Pull-Up

2-Wire/4Wire

RS485/RS422

130 Ohm Resistor on Transmit

1

2

3

4

5

6

Summary of Contents for CRS4Fxxxx-10x

Page 1: ...eration 8 Cable Specifications 9 Technical Specifications 12 Troubleshooting 13 Contact Us 14 Compliance Information 15 Part Number Port One Copper DB 9 port Port Two Fiber Optic CRS4F3111 100 RS485 4...

Page 2: ...ysical characteristics of the network installation techsupport transition com Click the Transition Now link for a live Web chat 3 Installation CAUTION Wear a grounding device and observe electrostatic...

Page 3: ...nstallation Continued Install the Slide In Module CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing the media converter Failure to observe this caution co...

Page 4: ...models Note Shielded RS485 422 cables are required for EMC compliance 1 Locate or build RS485 422 cables with a female DB 9 connector on one end and a DB 9 connector that is compatible with the other...

Page 5: ...data activity on the copper link Local switch settings Network commands cannot be entered via SNMP See the on line documentation that comes with Transition Networks FocalPoint software for applicable...

Page 6: ...14 100 1310 nm single mode Fiber optic Transmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 31 0 dBm max 8 0 dBm Link Budget 16 0 dB CRS4F3215 100 1310 nm single mode Fiber...

Page 7: ...or power faults Copper based media ports e g Twisted Pair TP Ethernet USB RS232 RS422 RS485 DS1 DS3 Video Coax etc are NOT to be connected to inter building outside plant link segments that are subjec...

Page 8: ...d in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interferenc...

Page 9: ...tive owners Copyright Restrictions 2004 2010 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without...