Transition Networks CDFTF1111-100 User Manual Download Page 5

CDFTFxxxx-10x

8

24-hour Technical Support: 

1-800-260-1312

-- International: 

00-1-952-941-7600

Technical Specifications

For use with Transition Networks Model CDFTFxxxx-10x or equivalent.

Standards

IEEE 802.3™

Data Rate

10 Mb/s

Dimensions

3.4" x 0.86" x 5.0" (86 x 22 x 127 mm)

Weight

3 oz  (91 g) (approximate)

Power Consumption

6.8 watts

MTBF

484,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
1,359,000 hours (Bellcore7 V5.0)

Environment

Tmra*:

0 to 60°C (32 to 140°F )

Storage Temp:

-20 to 85°C (-4 to 185°F)

Humidity:

5 to 95%, non condensing 

Altitude:

0 to 10,000 feet

Warranty

Lifetime

*Manufacturer’s rated ambient temperature:  Tmra range for this slide-in-module
depends on the physical characteristics and the installation configuration of the
Transition Networks PointSystem™ chassis in which this slide-in-module will be
installed.  

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.

CAUTION:  

Visible and invisible laser radiation when open.  Do not stare into

the beam or view directly with optical instruments.

CAUTION: 

Use of controls, adjustments or the performance of procedures other

than those specified herein may result in hazardous radiation exposure.

Operation 

-- Continued

SNMP

Use SNMP at an attached terminal or at a remote location to monitor the
media converter by monitoring:

Media converter power.

Copper link status on media converter #1.

Fiber link status on media converter #1.

Activity on media converter #1.

Copper link status on media converter #1.

Fiber link status on media converter #1.

Activity on media converter #1.

Also, use SNMP to enter network commands that:

Enable/disable AutoCross.

See the on-line documentation that comes with Transition Networks

FocalPoint™ 

software for commands and usage at www.transition.com.

9

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

Cable Specifications

The physical characteristics must meet or exceed IEEE 802.3™ specifications. 

Telco Copper Cable  

Maximum cable distance = 60 m (197 ft.)

Category 5: 

(minimum requirement)

Gauge

24 to 22 AWG

Attenuation 

22.0 dB /100m @ 100 MHz

(See page 4 for the Telco cable signal distribution over the 50-pin
connector at the back of the CPSMC1850-150 

PointSystem™

chassis.)

Fiber Cable 

Bit Error Rate:  

<10-9

Single mode fiber (recommended):

9 µm 

Multimode fiber (recommended):

62.5/125 µm 

Multimode fiber (optional):  

100/140, 85/140, 50/125 µm 

CDFTF1111-100

1300 nm multimode

CDFTF1313-100

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

CDFTF1414-100

1310 nm single mode

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Link Budget:

16.0 dB

CDFTF1515-100

1310 nm single mode

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -2.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

26.0 dB

CDFTF1616-100

1310 nm single mode

CDFTF1717-100

1550 nm single mode

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: 0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

29.0 dB

CDFTF2929-100

1310 nm (TX)/1550 nm (RX) simplex

CDFTF2929-101

1550 nm (TX)/1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

CDFTF2929-102

1310 nm (TX)/1550 nm (RX) simplex

CDFTF2929-103

1550 nm (TX)/1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.0 dBm

max: -3.0 dBm

Link Budget:

25.0 dB

The fiber optic transmitters on this device meets Class I Laser safety
requirements per IEC-825/CDRH standards and complies with 21
CFR1040.10 and 21CFR1040.11.

Summary of Contents for CDFTF1111-100

Page 1: ...0x series media converter installed at the front of the CPSMC1850 150 chassis Part Number Copper Twisted pair Telco signals Fiber Optic Two 2 external 100Base FX ports CDFTF1111 100 Two 2 internal sig...

Page 2: ...o twelve 12 installation slots in the front of the CPSMC1850 150 chassis I 0 RJ 21 Telco connector 2 RJ 21 Telco connector 1 3 techsupport transition com Click the Transition Now link for a live Web c...

Page 3: ...11 Receive 47 Port 11 Receive 23 Port 12 Transmit 48 Port 12 Transmit 24 Port 12 Receive 49 Port 12 Receive 25 N C 50 N C Chassis Slot 7 or13 Chassis Slot 8 or14 Chassis Slot 9 or15 Chassis Slot 10 or...

Page 4: ...cable to the media converter as shown Connect the fiber cable to the other device media converter hub etc as shown RX TX RX TX 7 techsupport transition com Click the Transition Now link for a live We...

Page 5: ...transition com 9 techsupport transition com Click the Transition Now link for a live Web chat Cable Specifications The physical characteristics must meet or exceed IEEE 802 3 specifications Telco Cop...

Page 6: ...Transition Now link for a live Web chat Contact Us Technical support is available 24 hours a day US Canada 1 800 260 1312 International 00 1 952 941 7600 Chat live via the Web with Transition Networks...

Page 7: ...ce regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A...

Reviews: