![Transition Networks CDFTF1111-100 User Manual Download Page 2](http://html1.mh-extra.com/html/transition-networks/cdftf1111-100/cdftf1111-100_user-manual_1151608002.webp)
CDFTFxxxx-10x
2
24-hour Technical Support:
1-800-260-1312
-- International:
00-1-952-941-7600
CDFTF2929
-100
and CDFTF2929
-101
are intended to be installed in the same
network where one is the local converter and the other is the remote converter.
CDFTF2929
-102
and CDFTF2929
-103
are intended to be installed in the same
network where one is the local converter and the other is the remote converter.
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network. (TX) = transmit, (RX) = receive
Part Number
Copper -
Twisted-pair
Telco signals
Fiber-Optic -
Two (2) external
100Base-FX ports
CDFTF2929-100
Two (2)
internal signals
SC, 1310 mn (TX)/1550 nm (RX)
20 km (12.4 miles)*
CDFTF2929-101
Two (2)
internal signals
SC, 1550 mn (TX)/1310 nm (RX)
20 km (12.4 miles)*
CDFTF2929-102
Two (2)
internal signals
SC, 1310 mn (TX)/1550 nm (RX)
40 km (24.8 miles)*
CDFTF2929-103
Two (2)
internal signals
SC, 1550 mn (TX)/1310 nm (RX)
40 km (24.8 miles)*
Part Number
Description
CPSMC1850-150
18-slot
PointSystem™
chassis with two (2) external RJ-21
Telco connectors. **
21HC45-6
Telco cable with RJ-21 connector at one end and twelve (12)
RJ-45 connectors at the other end.
21HC21-6
Telco cable with RJ-21 connectors at both ends.
Related Transition Networks Equipment
(sold separately)
**For more information on the CPSMC1850-150 chassis, see the user’s guide on-
line at www.transition.com
CPSMC1850-150 Chassis
The CPSMC1850-150
PointSystem™
chassis provides two (2) 50-pin Telco
connectors installed at the chassis back. The two Telco 50-pin connectors
concentrate a total of 24 UTP connections, which are distributed to twelve
(12) installation slots in the front of the CPSMC1850-150 chassis.
I
0
RJ-21 Telco connector #2
RJ-21 Telco connector #1
3
-- Click the
“Transition Now”
link for a live Web chat.
Telco Cables and Signals
The two kinds of Telco cables available from Transition Networks are pictured
below:
The signals from the Telco connectors are distributed as follows:
•
Signals from Telco connector #2 go to chassis slots 7 - 12.
•
Signals from Telco connector #1 go to chassis slots 13 - 18.
1
18
11
12
13
14
15
16
17
10
2
3
9
8
4
5
7
6
{
{
Telco connector #2
Telco connector #1
10BASE-T
INPOR
T
MCCM10
MGMT MASTER
OUTPOR
T
DB-9
12C
12C-1
TERM
INIT
CETTF100
LKF
PWR
RXF
RXC
LKC
RX
TX
10BASE-T
10BASE-FL
Media
Conversion
Center
Power
In Use
1
Power
In Use
2
RX
TX
LNK
PWR
RESET
DB-9
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
CDFTF100
Fiber Port #1
Fiber Port #2
In order to fully utilize the Telco option on the CPSMC1850-150 chassis, the
Transition Networks CDFTFxxxx-10x is required and it must be installed in
slots 7 through 18.
Please note:
•
Slots 1-6 on the CPSMC1850-150 are designed for any Transition
Networks media converter slide-in-module.
•
Slots 7-18 on the CPSMC1850-150 can accommodate any Transition
Networks media converter slide-in-module. However the Telco option
will not function unless a CDFTFxxxx-10x media converter is installed in
those slots.
21HC45-6:
one (1) RJ-21 connector
and 12 RJ-45 connectors
21HC21-6:
two (2) RJ-21 connector