Transition Networks CAPTF3311-100 User Manual Download Page 8

14

CAPTF33xx-1xx

24-hour Technical Support:

1-800-260-1312

-- International:

00-1-952-941-7600

Consumer Information

ACTA Compliance

This equipment complies with Part 68 of the FCC rules and the requirements adopted by the
Administrative Council for Terminal Attachments (ACTA).  On the back of this equipment is a
label that contains, among other information, a product identifier in the format
US:AAAEQ##TXXXX.  If requested, this number must be provided to the telephone company.

Plug and Jack

A plug and jack used to connect this equipment to the premises wiring and telephone
network must comply with the applicable FCC Part 68 rules and requirements adopted by the
ACTA.  A compliant telephone cord and modular plug is provided with this product.  It is
designed to be connected to a compatible modular jack that is also compliant.  See
installation instructions for details.

Ringer Equivalence Number

The Ringer Equivalence Number (REN) (listed on the label on the front of the device) is used
to determine the number of devices that may be connected to a telephone line.  Excessive
RENs on a telephone line may result in the devices not ringing in response to an incoming
call.  In most but not all areas, the sum of the RENs should not exceed five (5.0).  To be
certain of the number of devices that may be connected to a line, as determined by the total
RENs, contact the local telephone company.   

Harm to the Telephone Network

If the 

CAPTF33xx-1xx

causes harm to the telephone network, the telephone company will

notify you in advance that temporary discontinuance of service may be required.  But if
advance notice is not practical, the telephone company will notify the customer as soon as
possible.  Also, you will be advised of your right to file a complaint with the FCC if you
believe it is necessary.

Changes to the Telephone Company’s Network

The telephone company may make changes in its facilities, equipment, operations, or
procedures that could affect the operation of the 

CAPTF33xx-1xx

.  If this happens the

telephone company will provide advance notice in order for you to make necessary
modifications to maintain uninterrupted service.

Problems with the Equipment

If trouble is experienced with the 

CAPTF33xx-1xx

, for repair or warranty information, please

contact Transition Networks at 800-260-1312 x 200 or at www.transition.com.  If the
equipment is causing harm to the telephone network, the telephone company may request
that you disconnect the equipment until the problem is resolved.

Repairs to the Equipment

Aside from the jumper settings (described on page 5), the 

CAPTF33xx-1xx

is not intended to

be serviced by the user.  If the equipment requires repair, contact Transition Networks at 800-
260-1312 x200 or at www.transition.com.

Party Lines 

Connection to party line service is subject to state tariffs.  Contact the state public utility
commission, public service commission, or corporation commission for information.

Alarm Dialing Equipment

If your home has specially wired alarm equipment connected to the telephone line, ensure
the installation of the 

CAPTF33xx-1xx 

does not disable your alarm equipment.  If you have

questions about what will disable alarm equipment, consult your telephone company or a
qualified installer.

15

[email protected]

Select the “

Transition Now

” Link for a Live Web Chat

Contact Us

Technical Support

Technical support is available 24 hours a day.
US and Canada:

1-800-260-1312

International:

00-1-952-941-7600

Transition Now

Chat live via the Web with Transition Networks Technical Support.
Log onto 

www.transition.com

and click the 

Transition Now

link.

Web-Based Seminars

Transition Networks provides seminars via live web-based training.
Log onto 

www.transition.com

and click the 

Learning Center

link.

E-Mail

Ask a question anytime by sending an e-mail to our technical support staff.

[email protected]

Address

Transition Networks
6475 City West Parkway
Minneapolis, MN  55344, USA
telephone:

952-941-7600

toll free:

800-526-9267

fax:

952-941-2322

Declaration of Conformity

Name of Mfg:

Transition Networks 

6475 City West Parkway, Minneapolis MN 55344 USA

Model:

CAPTF33xx-1xx Series Media Converters

Part Number(s):

CAPTF3311-100, CAPTF3311-110, CAPTF3313-100, CAPTF3313-110, 
CAPTF3314-100, CAPTF3314-110, CAPTF3315-100, CAPTF3315-110,
CAPTF3329-100, CAPTF3329-110, CAPTF3329-101, CAPTF3329-111, 
CAPTF3329-102, CAPTF3329-112, CAPTF3329-103, CAPTF3329-113 

Regulation:

EMC Directive 89/336/EEC

Purpose:   To declare that the

CAPTF33xx-1xx

to which this declaration refers is in

conformity with the following standards.

CISPR 22:1997+A1:2000; EN 55022:1998+A1:2000 Class A; 55024:1998; FCC Part 15

Subpart B; TBR 21:1998; CS 03; TIA-968; 21 CFR Subpart J

I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s)

and Standard(s).

_February 17, 2003_____

Stephen Anderson, Vice-President of Engineering

Date

Summary of Contents for CAPTF3311-100

Page 1: ...mplement an end to end system An RJ 11 female connector provides the electrical interface between the media converter and the telephone device The CAPTF33xx 1xx is designed to be installed in the Transition Networks PointSystem chassis NOTE The the stand alone version of the media converter is SAPTF33xx 1xx For more information see the SAPTF33xx 1xx user s guide on line at www transition com CAPTF...

Page 2: ... in pairs The table below lists which models should be installed in the same network for the standard configuration see page 4 3 techsupport transition com Click the Transition Now link for a live Web chat Unit B CAPTF33xx 110 Unit B CAPTF33xx 110 the reciprocal unit to unit A connects to a telephone device and mimics a Central Office Customer Side FXO The available models are Typical maximum cabl...

Page 3: ...o and subsequent failure of the media converter Set the Jumpers Using small needle nosed pliers or similar device move the jumper to the desired position Refer to the drawings below Standard Automatic Ring Down The jumper labeled JP1 is used to switch between the Standard or Automatic Ring Down configuration and is located on the top circuit board of Unit B CAPTF33xx 110 The drawing below illustra...

Page 4: ...nel Fastener Screw 7 techsupport transition com Click the Transition Now link for a live Web chat Installation Continued Install the Cable Standard Configuration NOTE Unit B must be configured for Standard Configuration see page 4 Fiber 1 Locate or build fiber cable with male two stranded TX to RX connectors installed at both ends 2 Connect the fiber cables to Unit A CAPTF33xx 100 as described Con...

Page 5: ... to the RJ 11C port on the telephone device 3 Connect the copper cables to the second Unit B CAPTF33xx 110 as described in step 2 ACT SDF PWR TX RX ACT SDF PWR Copper TX RX Copper Connect to the RJ 11C connector on the telephone device Unit B Unit B Unit B 9 techsupport transition com Click the Transition Now link for a live Web chat Operation Power the Media Converter The CAPTF33xx 1xx media conv...

Page 6: ... Cable Specifications The physical characteristics must meet or exceed FCC part 68 specifications Copper Cable Category 1 Either shielded STP or unshielded UTP twisted pair is acceptable Gauge 24 to 22 AWG Maximum Nodes 2 Maximum Cable Length 5 meters 16 4 ft Unit A and CO 5 km 3 1 mi Unit B and telephone Fiber Cable Bit error rate 10 9 Single mode fiber recommended 9 µm Multimode fiber recommende...

Page 7: ... change For the most up to date information on the CAPTF33xx 1xx media converter view the user s guide on line at www transition com Product is certified by the manufacturer to comply with DHHS Rule 21 CFR Subchapter J applicable at the date of manufacture CAUTION Visible and Invisible Laser Radiation When Open Do Not Stare Into Beam Or View Directly With Optical Instruments CAUTION Use of control...

Page 8: ...he equipment is causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved Repairs to the Equipment Aside from the jumper settings described on page 5 the CAPTF33xx 1xx is not intended to be serviced by the user If the equipment requires repair contact Transition Networks at 800 260 1312 x200 or at www transition com Part...

Page 9: ...interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European Regulations Warning This is a Class A product In a domestic envi...

Reviews: