Installation 

-- Continued

Install the Slide-In-Module 

CAUTION:  

Wear a grounding device and observe electrostatic discharge

precautions when installing the media converter.

Failure to observe this

caution could result in damage to, and subsequent failure of, the media
converter.

To install the CAPTF33xx-1xx media converter slide-in-module:

1.

Locate an empty installation slot on the 

PointSystem™

chassis.

2.

Carefully slide the slide-in-module into the installation slot, aligning the
module’s circuit board with the installation guides.  

3.

Ensure that the module is firmly seated inside the chassis.

4.

Push in and rotate the attached attached panel fastener screw clockwise
to secure it the module to the chassis front.  

10BASE-T

 

INPOR

T

OUTPOR

T

DB-9

12C

12C-1

TERM

INIT

LKS

PWR

LKM

LKS

PWR

LKM

Multimode

Singlemode

TX

RX

TX

RX

LKF

PWR

RXF

RXC

LKC

SPD

PWR

FRX

CRX

FLNK

CLNK

RX

TX

100BASE-TX

RX

TX

100BASE-FX

Link Alert

E

D

0

50½

Multimode

Singlemode

TX

RX

TX

RX

LA

PWR

RXF

RXC

LNK

COL

10BASE-2

10BASE-FL

LKS

PWR

LKM

LKS

PWR

LKM

Multimode

Singlemode

TX

RX

TX

RX

Multimode

Singlemode

TX

RX

TX

RX

10BASE-T

 

10BASE-FL

Media

Conversion

Center

Power

In Use

1

Power

In Use

2

RX

TX

LNK

PWR

RESET

DB-9

Panel Fastener Screw

7

[email protected]

Click the “

Transition Now

” link for a live Web chat.

Installation 

-- Continued

Install the Cable -- Standard Configuration

NOTE:

Unit B 

must

be configured for Standard Configuration (see page 4).

Fiber

1.

Locate or build fiber cable with male, two-stranded TX to RX connectors
installed at both ends.

2.

Connect the fiber cables to 

Unit A

(CAPTF33xx-100) as described:  

Connect the male 

TX

cable connector to the female 

TX

port.

Connect the male 

RX

cable connector to the female 

RX

port.

3.

Connect the fiber cables to 

Unit B

(CAPTF33xx-110) as described:  

Connect the male 

TX

cable connector to the female

RX

port.

Connect the male 

RX

cable connector to the female 

TX

port.

Copper

1.

Locate or build copper cables with male, RJ-
11C connectors installed at both ends.

2.

Connect the copper cables to 

Unit A

(CAPTF33xx-100) as described:  

Connect the RJ-11C connector at one
end of the cable to the RJ-11C port 

on

Unit A

.

Connect the RJ-11C connector at the
other end of the cable to the RJ-11C port

on the Central Office

.

3.

Connect the copper cables to 

Unit B

(CAPTF33xx-110) as described:  

Connect the RJ-11C connector at one
end of the cable to the RJ-11C port 

on

Unit B

.

Connect the RJ-11C connector at the
other end of the cable to the RJ-11C port

on the telephone device

.

ACT   SDF   PWR

TX

RX

ACT   SDF   PWR

TX

RX

Copper

Connect to the 

RJ-11C connector

on the Central Office.

Copper

Connect to the 

RJ-11C connector

on the telephone device.

Unit A

Unit B

Unit A

Unit B

Summary of Contents for CAPTF3311-100

Page 1: ...mplement an end to end system An RJ 11 female connector provides the electrical interface between the media converter and the telephone device The CAPTF33xx 1xx is designed to be installed in the Transition Networks PointSystem chassis NOTE The the stand alone version of the media converter is SAPTF33xx 1xx For more information see the SAPTF33xx 1xx user s guide on line at www transition com CAPTF...

Page 2: ... in pairs The table below lists which models should be installed in the same network for the standard configuration see page 4 3 techsupport transition com Click the Transition Now link for a live Web chat Unit B CAPTF33xx 110 Unit B CAPTF33xx 110 the reciprocal unit to unit A connects to a telephone device and mimics a Central Office Customer Side FXO The available models are Typical maximum cabl...

Page 3: ...o and subsequent failure of the media converter Set the Jumpers Using small needle nosed pliers or similar device move the jumper to the desired position Refer to the drawings below Standard Automatic Ring Down The jumper labeled JP1 is used to switch between the Standard or Automatic Ring Down configuration and is located on the top circuit board of Unit B CAPTF33xx 110 The drawing below illustra...

Page 4: ...nel Fastener Screw 7 techsupport transition com Click the Transition Now link for a live Web chat Installation Continued Install the Cable Standard Configuration NOTE Unit B must be configured for Standard Configuration see page 4 Fiber 1 Locate or build fiber cable with male two stranded TX to RX connectors installed at both ends 2 Connect the fiber cables to Unit A CAPTF33xx 100 as described Con...

Page 5: ... to the RJ 11C port on the telephone device 3 Connect the copper cables to the second Unit B CAPTF33xx 110 as described in step 2 ACT SDF PWR TX RX ACT SDF PWR Copper TX RX Copper Connect to the RJ 11C connector on the telephone device Unit B Unit B Unit B 9 techsupport transition com Click the Transition Now link for a live Web chat Operation Power the Media Converter The CAPTF33xx 1xx media conv...

Page 6: ... Cable Specifications The physical characteristics must meet or exceed FCC part 68 specifications Copper Cable Category 1 Either shielded STP or unshielded UTP twisted pair is acceptable Gauge 24 to 22 AWG Maximum Nodes 2 Maximum Cable Length 5 meters 16 4 ft Unit A and CO 5 km 3 1 mi Unit B and telephone Fiber Cable Bit error rate 10 9 Single mode fiber recommended 9 µm Multimode fiber recommende...

Page 7: ... change For the most up to date information on the CAPTF33xx 1xx media converter view the user s guide on line at www transition com Product is certified by the manufacturer to comply with DHHS Rule 21 CFR Subchapter J applicable at the date of manufacture CAUTION Visible and Invisible Laser Radiation When Open Do Not Stare Into Beam Or View Directly With Optical Instruments CAUTION Use of control...

Page 8: ...he equipment is causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved Repairs to the Equipment Aside from the jumper settings described on page 5 the CAPTF33xx 1xx is not intended to be serviced by the user If the equipment requires repair contact Transition Networks at 800 260 1312 x200 or at www transition com Part...

Page 9: ...interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European Regulations Warning This is a Class A product In a domestic envi...

Reviews: