Transition Networks CAPTF3311-100 User Manual Download Page 1

Transition Networks CAPTF33xx-1xx POTS to fiber-optic media converter connects
central-office voice-grade signals to distant POTS (Plain Old Telephone Service)
equipment using standard telephone signaling.   It can extend, over fiber, the
distance between two voice path communication devices by up to 40 km using
either single mode or multimode fiber cable.  

The CAPTF33xx-1xx provides audio transmission, caller ID, ringing at the distant
end and automatic ring-down.  Two units are required to implement an end-to-end
system.  An RJ-11 female connector provides the electrical interface between the
media converter and the telephone device.   

The CAPTF33xx-1xx is designed to be installed in the Transition Networks

PointSystem™ 

chassis.

NOTE:  

The the 

stand alone version 

of

the media converter is 

SAPTF33xx-1xx

.

For more information, see the
SAPTF33xx-1xx user’s guide on-line at:
www.transition.com.

CAPTF33xx-1xx in the Network  . .4
Installation  . . . . . . . . . . . . . . . . . .5
Operation . . . . . . . . . . . . . . . . . . .9
Cable Specifications  . . . . . . . . . .11
RJ-11C Connector Specifications 12
Technical Specifications  . . . . . . .12
Troubleshooting  . . . . . . . . . . . . .13
Consumer Information  . . . . . . . .14
Compliance Information . . . . . . .16

POTS to Fiber Optic

Slide-in-Module Media Converter

CAPTF33xx-1xx

User’s Guide

Summary of Contents for CAPTF3311-100

Page 1: ...mplement an end to end system An RJ 11 female connector provides the electrical interface between the media converter and the telephone device The CAPTF33xx 1xx is designed to be installed in the Transition Networks PointSystem chassis NOTE The the stand alone version of the media converter is SAPTF33xx 1xx For more information see the SAPTF33xx 1xx user s guide on line at www transition com CAPTF...

Page 2: ... in pairs The table below lists which models should be installed in the same network for the standard configuration see page 4 3 techsupport transition com Click the Transition Now link for a live Web chat Unit B CAPTF33xx 110 Unit B CAPTF33xx 110 the reciprocal unit to unit A connects to a telephone device and mimics a Central Office Customer Side FXO The available models are Typical maximum cabl...

Page 3: ...o and subsequent failure of the media converter Set the Jumpers Using small needle nosed pliers or similar device move the jumper to the desired position Refer to the drawings below Standard Automatic Ring Down The jumper labeled JP1 is used to switch between the Standard or Automatic Ring Down configuration and is located on the top circuit board of Unit B CAPTF33xx 110 The drawing below illustra...

Page 4: ...nel Fastener Screw 7 techsupport transition com Click the Transition Now link for a live Web chat Installation Continued Install the Cable Standard Configuration NOTE Unit B must be configured for Standard Configuration see page 4 Fiber 1 Locate or build fiber cable with male two stranded TX to RX connectors installed at both ends 2 Connect the fiber cables to Unit A CAPTF33xx 100 as described Con...

Page 5: ... to the RJ 11C port on the telephone device 3 Connect the copper cables to the second Unit B CAPTF33xx 110 as described in step 2 ACT SDF PWR TX RX ACT SDF PWR Copper TX RX Copper Connect to the RJ 11C connector on the telephone device Unit B Unit B Unit B 9 techsupport transition com Click the Transition Now link for a live Web chat Operation Power the Media Converter The CAPTF33xx 1xx media conv...

Page 6: ... Cable Specifications The physical characteristics must meet or exceed FCC part 68 specifications Copper Cable Category 1 Either shielded STP or unshielded UTP twisted pair is acceptable Gauge 24 to 22 AWG Maximum Nodes 2 Maximum Cable Length 5 meters 16 4 ft Unit A and CO 5 km 3 1 mi Unit B and telephone Fiber Cable Bit error rate 10 9 Single mode fiber recommended 9 µm Multimode fiber recommende...

Page 7: ... change For the most up to date information on the CAPTF33xx 1xx media converter view the user s guide on line at www transition com Product is certified by the manufacturer to comply with DHHS Rule 21 CFR Subchapter J applicable at the date of manufacture CAUTION Visible and Invisible Laser Radiation When Open Do Not Stare Into Beam Or View Directly With Optical Instruments CAUTION Use of control...

Page 8: ...he equipment is causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved Repairs to the Equipment Aside from the jumper settings described on page 5 the CAPTF33xx 1xx is not intended to be serviced by the user If the equipment requires repair contact Transition Networks at 800 260 1312 x200 or at www transition com Part...

Page 9: ...interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European Regulations Warning This is a Class A product In a domestic envi...

Reviews: