FAULT ISOLATION and CORRECTION

If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:

1.

Is the Power LED on the media converter illuminated?
NO

Is the power adapter the proper voltage and cycle frequency for the
AC outlet? 
NOTE: Refer to the “Power Supply Requirements” on page 7. 

Is the power adapter properly installed in the media converter and
in the outlet?

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 2.

2.

Is the SDFiber (Signal Detect/Fiber) LED illuminated?
NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other media converter.

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 3.

3.

Is the SDTP (Signal Detect/Twisted-Pair) LED illuminated?
NO

Check twisted pair cables for proper connection.

Check RJ-45 Pinning Switch for correct twisted pair cable
configuration.

Check integrity of device attached to media converter by twisted-
pair cable.

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 4.

4.

Is the AISFiber LED on either media converter illuminated?
NO

Proceed to step 5.

YES

Determine if broken fiber link has caused All Ones Insertion (AIS)
on the fiber interface and correct failure. If not, proceed to step 5.

Set switches 5, 6, and 7 to
enable test functions or to
permit normal network
operation. (Switch 8 not used.)

Set the MDI/MDI-X switch to use straight-through cable where crossover-
configuration cable is required.

1

2

1

2

1

2

1

2

1

2

1

2

Loop Transmit TP

to Receive TP

NO Transmit All Ones 

onto Fiber

Transmit All Ones onto

Fiber on loss of SDFiber

Normal Operation

NO Transmit All Ones 

onto Twisted-Pair

Transmit All Ones onto

TP on loss of SDTP

5  6  7  8

*NETWORK Switch Settings

*Switch #8 not used.

1     2     3     4 

5     6     7     8 

Twisted
Pair  #1

Twisted
Pair  #2

1

2

4

5

RTIP

TTIP

RRING

TRING

TTIP

RTIP

TRING

RRING

RTIP

TTIP

RRING

TRING

RTIP

TTIP

RRING

TRING

Twisted
Pair  #1

Twisted
Pair  #2

1

2

4

5

MDI

MDI-X

Connectors for unlike devices

Connectors for like devices

KEY

=  UP

=  DOWN

Fiber

TP

TP

AISFiber

Summary of Contents for C/T1E1-CF-01

Page 1: ...999 2001 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A 33111 D CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telepho...

Page 2: ...equirement Location 3507 240 volts 50 hertz United Kingdom 3342 230 volts 50 hertz Europe 3340 120 volts 60 hertz USA Canada Mexico 3346 100 volts 50 60 hertz Japan 3511 240 volts 50 hertz Australia 3537 with power cord 3522 South Africa NOTE This product also can be powered by the Transition Networks E MCR series media converter rack Warranty Lifetime DECLARATION OF CONFORMITY Name of Mfg Transit...

Page 3: ...hite blue for the active pins Category 3 or better twisted pair copper wire is required Either shielded twisted pair STP or unshielded twisted pair UTP can be used T1 Gauge 24 to 22 AWG Attenuation 2 6 dB 100 meters 1 0 MHz Differential Characteristic Impedance 100 Ω 10 E1 Gauge 24 to 22 AWG Attenuation 2 6 dB 100 meters 1 0 MHz Differential Characteristic Impedance 120 Ω 10 Coax Copper Cable E1 G...

Page 4: ...es Insertion AIS on the twisted pair interface NO Contact Technical Support 800 260 1312 800 LAN WANS SHORT HAUL Switch Settings Switch 4 UP 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 E1 2 37V 75 ohm cable Coax connectors E1 3 0V 120 ohm cable RJ 45 connector DSX 1 0 133 100 ohm cable DSX 1 133 266 100 ohm cable DSX 1 266 399 100 ohm cable DSX 1 399 533 100 ohm cable DSX 1 533 655 100 ohm cable ANSI T1 4...

Page 5: ...sted pair cable configuration Check integrity of device attached to media converter by twisted pair cable Contact Technical Support 800 260 1312 800 LAN WANS YES Proceed to step 4 4 Is the AISFiber LED on either media converter illuminated NO Proceed to step 5 YES Determine if broken fiber link has caused All Ones Insertion AIS on the fiber interface and correct failure If not proceed to step 5 Se...

Page 6: ...build coax cables that are compliant with specifications on page 10 Connect BNC connector at one end of cable to media converter Connect BNC connector at other end of cable to network equipment FIBER Locate or build duplex fiber cables that are compliant with specifications on page 10 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on media c...