Transition Networks C/T1E1-CF-01 User Manual Download Page 3

CABLE SPECIFICATIONS

Fiber Cable 

Bit error rate:

10-9

MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

C/T1E1-CF-01

850 nM

Fiber Optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber Optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Typical Maximum Cable Distance*:

2 kilometers

C/T1E1-CF-01(SC)

850 nM

Fiber-optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Typical Maximum Cable Distance*:

2 kilometers

SINGLEMODE

Fiber Optic Cable Recommended:

9 µm singlemode fiber

C/T1E1-CF-01(SM)

1300 nM

Fiber-optic Transmitter Power:

min: -21.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

Typical Maximum Cable Distance*:

8 kilometers

C/T1E1-CF-01(LH)

1300 nM

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -5.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

Typical Maximum Cable Distance*:

15 kilometers

*Actual distance dependent upon physical characteristics of network installation.

Twisted-Pair Copper Cable 

Twisted pair connection requires two active pairs. The two active pairs in a T1/E1
network are pins 1 & 2 and pins 4 & 5. Use only dedicated wire pairs (such as
blue/white & white/blue) for the active pins.

Category 3 or better twisted-pair copper wire is required. Either shielded twisted-
pair (STP) or unshielded twisted-pair (UTP) can be used. 

T1:

Gauge

24 to 22 AWG

Attenuation 

2.6 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance 

100 

±10% 

E1:

Gauge

24 to 22 AWG

Attenuation 

2.6 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance 

120 

±10%  

Coax Copper Cable 

E1:

Gauge

24 to 22 AWG

Attenuation 

2 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance 

75 

±10%

å

Dry-Contact Relay

RJ-45 dry-contact relay opens if power, signal detect/copper or signal
detect/fiber are lost.

Operational rating on pins 3 and 6: 0-30VDC maximum 1A

Switch-Selectable Configurations

T1 COPPER RJ-45 

Configured as either "long haul" or “short haul” on 100 ohm cable, with
a variety of selectable distance settings.

E1 COPPER RJ-45 

Configured as either "long haul" or “short haul” on 120 ohm cable.

E1 COPPER COAX 

Configured as either "long haul" or “short haul” on 75 ohm cable.

STRAIGHT-THROUGH/CROSSOVER RJ-45

Allows straight-through cable to be used where crossover-configuration
cable is required.

Switch-Selectable Functions

LOOPBACK TEST FUNCTION

A loopback switch facilitates installation and network debug procedures.

The path for the C/T1E1-CF-01 loopback is shown:

TRANSMIT ALL ONES FUNCTION

A selectable Transmit All Ones switch on the fiber interface and on the
twisted-pair interface allows for insertion of an “all ones” pattern on that

Fiber

TP

TP

RJ-45

Relay

3

6

Summary of Contents for C/T1E1-CF-01

Page 1: ...999 2001 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A 33111 D CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telepho...

Page 2: ...equirement Location 3507 240 volts 50 hertz United Kingdom 3342 230 volts 50 hertz Europe 3340 120 volts 60 hertz USA Canada Mexico 3346 100 volts 50 60 hertz Japan 3511 240 volts 50 hertz Australia 3537 with power cord 3522 South Africa NOTE This product also can be powered by the Transition Networks E MCR series media converter rack Warranty Lifetime DECLARATION OF CONFORMITY Name of Mfg Transit...

Page 3: ...hite blue for the active pins Category 3 or better twisted pair copper wire is required Either shielded twisted pair STP or unshielded twisted pair UTP can be used T1 Gauge 24 to 22 AWG Attenuation 2 6 dB 100 meters 1 0 MHz Differential Characteristic Impedance 100 Ω 10 E1 Gauge 24 to 22 AWG Attenuation 2 6 dB 100 meters 1 0 MHz Differential Characteristic Impedance 120 Ω 10 Coax Copper Cable E1 G...

Page 4: ...es Insertion AIS on the twisted pair interface NO Contact Technical Support 800 260 1312 800 LAN WANS SHORT HAUL Switch Settings Switch 4 UP 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 E1 2 37V 75 ohm cable Coax connectors E1 3 0V 120 ohm cable RJ 45 connector DSX 1 0 133 100 ohm cable DSX 1 133 266 100 ohm cable DSX 1 266 399 100 ohm cable DSX 1 399 533 100 ohm cable DSX 1 533 655 100 ohm cable ANSI T1 4...

Page 5: ...sted pair cable configuration Check integrity of device attached to media converter by twisted pair cable Contact Technical Support 800 260 1312 800 LAN WANS YES Proceed to step 4 4 Is the AISFiber LED on either media converter illuminated NO Proceed to step 5 YES Determine if broken fiber link has caused All Ones Insertion AIS on the fiber interface and correct failure If not proceed to step 5 Se...

Page 6: ...build coax cables that are compliant with specifications on page 10 Connect BNC connector at one end of cable to media converter Connect BNC connector at other end of cable to network equipment FIBER Locate or build duplex fiber cables that are compliant with specifications on page 10 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on media c...