OPERATION 

After installation, the media converter should function without operator
intervention. 

Status LEDs

Use the status LEDs to monitor media converter operation in the network. 

P(o)w(e)r

Illuminated
green LED
indicates
connection to
external AC
power.

Link

Steady green
LED indicates that fiber link is connected properly.

FAULT ISOLATION and CORRECTION

If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:

1.

Is the power LED on the media converter illuminated?
NO

Ensure that media converter is seated firmly in E-MCC-1600 chassis?

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 2.

2.

Is the multimode fiber Link LED illuminated?
NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on the other device.

Power-cycle the media converter.

Refer to Tech Tips available at: http://www.transition.com

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 3.

3.

Is the singlemode fiber Link LED illuminated?
NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on the other device.

Power-cycle the media converter.

Refer to Tech Tips available at: http://www.transition.com

YES

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

Summary of Contents for C/F-SM-MM-02(LH)

Page 1: ...cifiques appropriées Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 1997 2000 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A 33046 D Designed to be ...

Page 2: ...ORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model C F SM MM 02 Series Media Converters Part Number s C F SM MM 02 C F SM MM 02 LH C F SM MM 02 XL C F SM MM 02 LW Regulation EMC Directive 89 336 EEC Purpose To declare that the C F SM MM 02 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class A EN 55022 1988...

Page 3: ...istance 60 kilometers C F SM MM 02 LW 1550 nM Fiber optic Transmitter Power min 5 0 dBm max 0 0 dBm Fiber optic Receiver Sensitivity min 34 0 dBm max 7 0 dBm Minimum Cable Distance 30 kilometers Maximum Cable Distance 80 kilometers INSTALLATION Install Slide In Module in E MCC 1600 Chassis NOTE Media Converter Slide in Modules can be installed in any installation slot in any order Remove Media Con...

Page 4: ...MCC 1600 chassis Contact Technical Support at 800 260 1312 800 LAN WANS YES Proceed to step 2 2 Is the multimode fiber Link LED illuminated NO Check fiber cables for proper connection Verify that TX and RX cables on media converter are connected to RX and TX ports respectively on the other device Power cycle the media converter Refer to Tech Tips available at http www transition com Contact Techni...

Reviews: