Transition Networks C/F-SM-MM-02(LH) User Manual Download Page 3

CABLE SPECIFICATIONS

The physical characteristics of the media cable must meet or exceed IEEE 802.3 specifications. 

155 Mb/s Fiber Specifications

Bit error rate:

10-9

MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Wavelength :

1300 nM

Maximum Cable Distance:

2 kilometers

SINGLEMODE

Fiber Optic Cable Recommended:

9 µm singlemode fiber

C/F-SM-MM-02

1300 nM

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.5 dBm

max: -8.0 dBm

Maximum Cable Distance:

20 kilometers

C/F-SM-MM-02(LH) 

1300 nM

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -8.0 dBm

Minimum Cable Distance:

15 kilometers

Maximum Cable Distance:

40 kilometers

C/F-SM-MM-02(XL) 1300 

nM

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: 0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Minimum Cable Distance:

15 kilometers

Maximum Cable Distance:

60 kilometers

C/F-SM-MM-02(LW) 

1550 nM

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: -0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Minimum Cable Distance:

30 kilometers

Maximum Cable Distance:

80 kilometers

INSTALLATION 

Install Slide-In-Module in E-MCC-1600 Chassis

NOTE: Media Converter Slide-in-Modules can be installed in any
installation slot, in any order.

Remove Media Converter Slide-in-Module protective plate from selected
installation slot by removing two (2) screws that secure plate to front of
E-MCC-1600. 

Carefully slide Media Converter Slide-in-Module into installation slot,
aligning Media Converter Slide-in-Module with installation guides.

NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated
against the backplane.

Secure Slide-in-Module by securing panel fastener screw attached to
Slide-in-Module to E-MCC-1600 chassis.

Install Cable

NOTE: Be sure to connect correct speed fiber cable at each connector.

Locate or build fiber cable with male two-stranded TX to RX connectors
appropriate to the media converter installed at both ends.

Connect male TX and RX cable connectors at one end of cable to TX
and RX female connectors, respectively, on media converter.

Connect male TX and RX cable connectors at other end of cable to RX
and TX connectors of 802.3 compliant fiber device.

Summary of Contents for C/F-SM-MM-02(LH)

Page 1: ...cifiques appropriées Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 1997 2000 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A 33046 D Designed to be ...

Page 2: ...ORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model C F SM MM 02 Series Media Converters Part Number s C F SM MM 02 C F SM MM 02 LH C F SM MM 02 XL C F SM MM 02 LW Regulation EMC Directive 89 336 EEC Purpose To declare that the C F SM MM 02 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class A EN 55022 1988...

Page 3: ...istance 60 kilometers C F SM MM 02 LW 1550 nM Fiber optic Transmitter Power min 5 0 dBm max 0 0 dBm Fiber optic Receiver Sensitivity min 34 0 dBm max 7 0 dBm Minimum Cable Distance 30 kilometers Maximum Cable Distance 80 kilometers INSTALLATION Install Slide In Module in E MCC 1600 Chassis NOTE Media Converter Slide in Modules can be installed in any installation slot in any order Remove Media Con...

Page 4: ...MCC 1600 chassis Contact Technical Support at 800 260 1312 800 LAN WANS YES Proceed to step 2 2 Is the multimode fiber Link LED illuminated NO Check fiber cables for proper connection Verify that TX and RX cables on media converter are connected to RX and TX ports respectively on the other device Power cycle the media converter Refer to Tech Tips available at http www transition com Contact Techni...

Reviews: