![Transition Networks C/F-SM-MM-02(LH) User Manual Download Page 3](http://html.mh-extra.com/html/transition-networks/c-f-sm-mm-02-lh/c-f-sm-mm-02-lh_user-manual_1151535003.webp)
CABLE SPECIFICATIONS
The physical characteristics of the media cable must meet or exceed IEEE 802.3 specifications.
155 Mb/s Fiber Specifications
Bit error rate:
≤
10-9
MULTIMODE
Fiber Optic Cable Recommended:
62.5 / 125 µm multimode fiber
Optional:
100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -32.5 dBm
max: -14.0 dBm
Wavelength :
1300 nM
Maximum Cable Distance:
2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended:
9 µm singlemode fiber
C/F-SM-MM-02
1300 nM
Fiber-optic Transmitter Power:
min: -15.0 dBm
max: -8.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.5 dBm
max: -8.0 dBm
Maximum Cable Distance:
20 kilometers
C/F-SM-MM-02(LH)
1300 nM
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -8.0 dBm
Minimum Cable Distance:
15 kilometers
Maximum Cable Distance:
40 kilometers
C/F-SM-MM-02(XL) 1300
nM
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Minimum Cable Distance:
15 kilometers
Maximum Cable Distance:
60 kilometers
C/F-SM-MM-02(LW)
1550 nM
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: -0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Minimum Cable Distance:
30 kilometers
Maximum Cable Distance:
80 kilometers
INSTALLATION
Install Slide-In-Module in E-MCC-1600 Chassis
NOTE: Media Converter Slide-in-Modules can be installed in any
installation slot, in any order.
•
Remove Media Converter Slide-in-Module protective plate from selected
installation slot by removing two (2) screws that secure plate to front of
E-MCC-1600.
•
Carefully slide Media Converter Slide-in-Module into installation slot,
aligning Media Converter Slide-in-Module with installation guides.
NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated
against the backplane.
•
Secure Slide-in-Module by securing panel fastener screw attached to
Slide-in-Module to E-MCC-1600 chassis.
Install Cable
NOTE: Be sure to connect correct speed fiber cable at each connector.
•
Locate or build fiber cable with male two-stranded TX to RX connectors
appropriate to the media converter installed at both ends.
•
Connect male TX and RX cable connectors at one end of cable to TX
and RX female connectors, respectively, on media converter.
•
Connect male TX and RX cable connectors at other end of cable to RX
and TX connectors of 802.3 compliant fiber device.