14
S4TEF10xx-10x
.
Technical Specifications
For use with Transition Networks Model S4TEF10xx-10x or equivalent.
Standards
G.703, AMI/B8Zs/HDB3
Data Rate
Fiber: 100 Mb/s
Dimensions
3.7" x 4.7" x 1.8" (93 mm x 120 mm x 47 mm)
Weight
1 lb. (0.45 kg) (approximate)
Power Consumption
6.0 watts
Power Supply
12 VDC, 0.8 Amp (North. Am., EU, Latin Am., Japan)
12 VDC, 1.25 Amp (UK, Australia, N.Z., South Africa)
(The external power supply provided with this product
is UL listed by the power supplier’s manufacturer.)
Environment
Tmra*:
0 to 50°C (32 to 122°F )
Storage Temperature:
-40 to 85°C (-40 to 185°F)
Humidity:
5 to 95%, non condensing
Altitude:
to 10,000 feet
Warranty
Lifetime
*Manufacturer’s rated ambient temperature.
The information contained in this user’s guide is subject to change. For the most
up-to-date information on the S4TEF10xx-10x media converter, see the user’s
guide on-line at: www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into
beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Optional Accessories
The following items are available from Transition Networks
Part Number
Description
SPS-1872-SA
Optional External Power Supply; 18-72VDC Stand-Alone
Output: 12.6VDC, 1.0 A
WMBL
Optional Wall Mount Bracket; 4.0 in. (102 mm)
WMBV
Optional Vertical Mount Bracket; 5.0 in. (127 mm)
WMBD
Optional DIN Rail Mount Bracket; 5.0 in. (127 mm)
15
.
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:
1.
Is the “PWR” LED illuminated?
NO
• Ensure that the power adapter is the proper type of voltage and cycle
frequency for the outlet (See “Power Supply” on page 14.)
• Ensure the power adapter is properly installed in the media converter
and in the grounded outlet.
.
YES
• Proceed to step 2.
2.
Is the “LKF” LED illuminated?
NO
• Check the fiber cables for proper connection.
• Verify that the TX and RX cables on the local media converter are
connected to the RX and TX ports, respectively, on the remote media
converter.
YES
• Proceed to step 3.
3.
Is the “LNK” LED on a T1/E1port (with a copper cable installed)
illuminated?
NO
• Check the copper cable connected to that T1/E1 port for proper
connection.
• .
YES
• Proceed to step 4.
4.
Is the “AIS” LED on a T1/E1 port (with a copper cable installed)
illuminated?
YES
• The device connected to the T1/E1 port has failed. Correct the device
failure.
• .
NO
• Proceed to step 5.